Request A Quote
Whiteness Meter LWM-A11

Whiteness Meter LWM-A11

Whiteness Meter LWM-A11 offers an incidence angle of 45/0, capturing both color and surface appearance for visually accurate whiteness readings. It has a moisture-resistant design for reliable operation in humid or damp environments. The system applies a blue-light whiteness formula to accurately measure brightness with consistent alignment. Our whiteness tester features a long-lasting light source, ensuring consistent measurement accuracy over the device’s operational lifetime.

Whiteness Meter LWM-A11_Front View
Whiteness Meter LWM-A11_Side View
Request Quote
Incidence Angle 45/0
Measurement Range 0 to199.9
Whiteness Formula Whiteness of Blue Light
Light Source D65
Repeatability 0.2
Power Supply 1.5V AA
Weight 300 g
  • Fluorescent Whiteness Measurement

  • Calibrated White Board

  • Quick Measurement Cycles

  • Pocket-Sized Portability

  • Low Power Consumption

 

Whiteness Meter LWM-A11 quantifies a surface or powder’s whiteness by measuring blue-light reflectance. It plays a key role in ceramics, chemical material, printing inks, and dyeing industries for ensuring uniform whiteness.

Download catalog for
Whiteness Meter LWM-A11 Catalog

Models of Paper Testing Instruments

Labtron Paper Testing Instruments requires air supply for automatic clamping, ensuring smooth and secure operation. These provide real-time pressure curve displays, allowing users to monitor pressure changes instantly. Their over-range reset function protects the sensor by automatically adjusting it in case of excessive readings. They measure ink absorption values, useful for quality control in printing processes. Our paper testing instruments measure WH Hunter whiteness, YI yellowness, and CIE whiteness for precise color and whiteness evaluations for various applications.

Pulp beating (refining) freeness tester TP-C10

Pulp beating (refining) freeness tester TP-C10

  • Measurement range : 0 to 100° SR
  • Sealed testing speed : 100 ± 10 mm/s
  • Volume of distilled water : 1000 ± 5 ml
  • Draining time : 149 ± 1 s
Internal Ply Bond Tester TP-J11

Internal Ply Bond Tester TP-J11

  • Measuring Range : A file: 20 to 500 J/m² B file: 500 to 1000 J/m²
  • Specimen Size : 25.4mm × 25.4mm
  • Sample Clamping Force : 0 to 400N (adjustable)
  • Impact Angle : 90°
Electronic Tearing tester TP-J21

Electronic Tearing tester TP-J21

  • Capacity : 10 -16000 mN
  • Resolution : 0.1 mN
  • Tearing arm : 104 ± 1 mm
  • Tearing angle : 27.5° ± 5°
Electronic Tear Tester LET-A10
Electronic Tear Tester LET-A10
  • Measuring Range : 10 to 64000 mN
  • Power of Resolution : 0.1 mN
  • Test Accuracy : ± 1%
  • Tearing Force Arm : 104 ± 1 mm
Digital Paper Thickness Tester TP-E30
Digital Paper Thickness Tester TP-E30
  • Measuring range : 0 to 5 mm
  • Division value : 0.001 mm
  • Measuring parallelism : ≤ 0.002 mm
  • Indication error : ± 0.0025 mm or ± 0.5 %
Ink Rub Tester LIRT-A10

Ink Rub Tester LIRT-A10

  • Sample Area : 230 × 60 mm
  • Friction Stroke : 60 mm
  • Frequency Setting : 0 to 9999 auto-complete
  • Friction Area : 150 × 50 mm
Water absorption tester- Cobb Tester TP-C21

Water absorption tester- Cobb Tester TP-C21

  • Metal Cylinder inner area : (100 ± 0.2) cm2
  • Metal Cylinder height : 50 mm
  • Metal roller width : (200 ± 0..5) mm
  • Metal roller weight : (10 ± 0.5) kg
COBB sample cutter TP-C30

COBB sample cutter TP-C30

  • Sample diameter : 125 mm
  • Sample error : ± 0.2 mm
  • Sample Thickness : 0.1 to 1.0 mm
  • Dimension : 240×288×435 mm
Whiteness Meter LWM-A11 FAQ's
  • Yes. Labtron’s whiteness meter LWM-A11 double as spectrophotometers, measuring brightness (reflectance at approximately 457?nm), opacity, transparency, and chromaticity. Advanced units also derive absorption/scattering coefficients and quantify OBA content per ISO 15397. Portable models support data logging and pass/fail functionality, enabling more comprehensive quality control in paper, textile, plastic, food, and construction material industries.

  • Labtron supplies advanced whiteness meter LWM-A11.Measurement accuracy can be influenced by surface characteristics—glossy or uneven textures reflect light unpredictably—and ambient light interference. Sample preparation, including cleanliness and orientation, can also introduce variation. Instrument drift due to lamp aging or sphere discoloration can cause baseline shifts. UV-filter control is vital when measuring fluorescent materials. To ensure consistent results, use controlled environments, clean optics, and adhere strictly to standard measurement geometries and protocols.

  • Labtron supplies advanced whiteness meter LWM-A11.Selecting an appropriate whiteness meter depends on your application. Choose a model designed for your material type—paper, textiles, plastics, or powders. Confirm support for relevant standards (ISO 2470/2469, ASTM E313, CIE). For fluorescent materials, ensure UV filter control. Match instrument geometry (45°/0° or integrating sphere) to sample type. Consider whether a portable handheld device or benchtop system suits your workflow. Review features like data storage, connectivity, connectivity (USB/Bluetooth), and durability to ensure a tool that aligns with your quality-control needs.

  • Yes, Labtron supplies advanced whiteness meter LWM-A11.These systems often feature conveyor integration or robotic positioning and provide real-time feedback for process control. Inline meters typically share core measurement principles with benchtop models but are ruggedized and designed for continuous operation. They include automated calibration routines, UV compensation, and centralized data logging to maintain quality without manual intervention—making them ideal for large-scale manufacturing.

  • Labtron supplies advanced whiteness meter LWM-A11. For powders, starch, sugar, or granules, compaction into a tablet or insertion into a powder sample holder is required before measurement. Ensure homogeneous particle size and consistent packing density to avoid air gaps and uneven surface reflection. Many instruments specify sample mass (e.g., ??5?g) and container dimensions to standardize readings. Thorough shaking and leveling of the powder improves repeatability, and cleaning the aperture after each measurement prevents residual interference

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.