Request A Quote
HDT and Vicat Testing Machine TVHT-A10

HDT and Vicat Testing Machine TVHT-A10

HDT and Vicat Testing Machine TVHT-A10 comes with a maximum deformation measurement range of 1mm for Vicat tests and 0.33mm for thermal deformation tests. The sample frame is manually operated, allowing users to position and adjust samples during testing. The PID program of our HDT and Vicat testing machine controls the heating time of heater for precise temperature regulation and reliable testing.
HDT and Vicat Testing Machine TVHT-A10
HDT and Vicat Testing Machine TVHT-A10
Request Quote
Structure Table Type
Maximum Deformation Measurement Range 1mm (Vicat Test); 0.33mm (Thermal Deformation)
Display 7-inch Touch Screen
Sample Frame Manual
Temperature Range RT to 300℃
Heating Speed 120℃/h [(12±1) ℃/6min]
50℃/h [(5±0.5) ℃/6min]
Maximum Temperature Error ±0.5℃
Heating Medium Methyl Silicone Oil (below 200 centistokes)
Maximum Heating Power 3kW
Working Positions 3 (Optional: 4 or 6)
Cooling Method Natural Cooling
Load Deformation Temperature Methods Method A: 1.80MPa Bending Stress
Method B: 0.45MPa Bending Stress
Method C: 8.00MPa Bending Stress
Mass of Load Bar and Pallet 68g ± 1g
Power Supply AC220V, 10A, 50Hz
Packaging Dimension 930 × 690 × 920 mm
Dimension 910 × 670 × 740 mm
Net weight 123 Kg
Gross weight 128 Kg
  • Tabletop design
  • Easy operation
  • 7-inch Touch Screen
  • Natural cooling
HDT and Vicat Testing Machine TVHT-A10 is ideal for testing plastics, hard rubber, nylon, electrical insulators, reinforced composites, and other non-metallic materials.
Mainframe × 1 Set
Main Control Board × 1 Set
Test Stand × 3 Sets
Test Frame Span × 1 Set
Motion Detector × 3 Sets
Temperature Sensor × 1 Suit
Thermal Deformation × 3 Sets
Vicat Test Indenter × 3 Sets
Transformer Power Supply × 1 Set
Voltage Regulating Module × 1 Set
Micro Printer × 1 Set
Dial Indicator Data Line × 1 Set
HDT and Vicat Testing Machine TVHT-A10
HDT and Vicat Testing Machine TVHT-A10

Models of Plastic Testing Instruments

Labtron Plastic Testing Instruments has a microprocessor-controlled PID system that ensures precise temperature balance for consistent results. These include an inside chamber constructed from durable stainless steel, offering long-lasting reliability. Their test samples retain their physical properties even after aging, ensuring accurate assessments. They have adopted a double-pipe structure for enhanced durability and performance. Our plastic testing instruments effectively determine the anti-impact properties of materials, providing valuable data for material testing and quality control.

Charpy/ Izod Impact Tester TCI-A10

Charpy/ Izod Impact Tester TCI-A10

  • Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
  • Impact energy (Izod) : 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
  • Resolution of impact energy : 0.001 J
  • Pendulum up angle : 160°
Falling Weight Impact Tester LFWIT-A10

Falling Weight Impact Tester LFWIT-A10

  • Dart Head Mass : 50 to 2000
  • Mass Increment : 5 g
  • Impact Height : 1500 mm
  • Dart Head Quality : A method: R38 ± 1 mm B method: R50 ± 1 mm
Vacuum Leak Tester TVLT-A10

Vacuum Leak Tester TVLT-A10

  • Vacuum degree : 0 to 90 KPa
  • Accuracy : 1 % FS
  • Resolution : 0.1 KPa
  • Vacuum chamber effective size : 270 × 210 mm
Falling Weight Impact Tester TFWT-A11
Falling Weight Impact Tester TFWT-A11
  • Maximum Sample Length : 6 inches (152.4mm)
  • Test Temperature : 23 ℃ ± 2 ℃
  • Sample Size Range : 16 mm to 152 mm
  • Anvil Size : 13 mm steel Plate
Heat sealer THS-A10
Heat sealer THS-A10
  • Seal temperature : Room temperature -250°C
  • Control accuracy : ± 0.2°C
  • Dwell time : 0.1 S to 999.9 S
  • Dwell pressure : 0.05 to 0.7 MPa
Lasting adhesive tester TLAT-A10

Lasting adhesive tester TLAT-A10

  • Standard roller : 2000 ± 50 g
  • Testing stations : 3
  • Dimension (L*W*H) tester : 320×210×550 mm (3 stations)
  • Weight for stations : 10 kg (3 stations)
Melt flow Indexer TMFI-A11

Melt flow Indexer TMFI-A11

  • Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate : 0.001 S
  • Temperature range : 50 to 400°C
  • Temperature precision : ± 0.5°C
Oxygen Index Tester TOIT-A10

Oxygen Index Tester TOIT-A10

  • Resolution : 0.1 % O2
  • Measuring range : 0 to 100 % O2
  • Precision : ± 0.4 % O2
  • Response time : < 10 S

Plastic Testing Instruments:
Charpy/ Izod Impact Tester TCI-A10, Falling Weight Impact Tester LFWIT-A10, Vacuum Leak Tester TVLT-A10, Falling Weight Impact Tester TFWT-A11, Heat sealer THS-A10, Lasting adhesive tester TLAT-A10, Melt flow Indexer TMFI-A11, Oxygen Index Tester TOIT-A10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608