| Temperature Range | –30 to 5°C |
| Temperature Control Accuracy | ±2°C |
| Ambient Temperature | 5 to 35°C |
| Cooling Method | Air cooling |
| Cooling Capacity at 0°C | 2800 W |
| Cooling Capacity at –10°C | 1800 W |
| Cooling Capacity at –20°C | 1000 W |
| Cooling Capacity at –25°C | 500 W |
| Refrigerant | R410A |
| Rated Pump Flow Rate | 20 L/min |
| Rated Pump Power | 0.4 bar |
| Outer Circulation Interface Size | Rc 1/2 |
| Reservoir Capacity | 30 L |
| Protection Grade | IP20 |
| Power Supply | 220 to 240 V, 50 Hz |
| Power Consumption | 1940 W |
| Dimensions (W×D×H) | 495 × 760 × 860 mm |
| Net Weight | 100 kg |
Front-facing drain port
Shock-protected cable housing
Ergonomic lifting side handles
Anti-static outer enclosure
Overload-safe electrical fuse
Recirculating Chillers LRC-L14 provides external cooling support for laboratory and industrial equipment during thermal regulation processes. This enables temperature stability for bioreactors, evaporators, material testing systems, and semiconductor applications.
Download catalog for
Recirculating Chillers LRC-L14 Catalog
Available Range :
Recirculating Chiller LRC-F10 : -100°C to 90°C Recirculating Chiller LRC-A12 : -20 ℃ to RT Recirculating Chiller LRC-L10 : -20°C to RT Recirculating Chiller LRC-A11 : -20℃ to RT Recirculating Chiller LRC-C10 : -25°C to 90°C Recirculating Chiller LRC-D10 : -45°C to 90°C Recirculating Chiller LRC-E10 : -80°C to 90°C Recirculating Chiller LRC-B10 : 5°C to 90°C Recirculating Chiller LRC-A10 : 5˚C to 40˚C Recirculating Chillers LRC-L11 : –20 to 25°C Recirculating Chillers LRC-L12 : –30 to 5°CLabtron Recirculating Chiller provide cooling of fluids from -5℃ to 40℃ by circulating them through system to remove heat. They include evaporators to absorb thermal energy from liquid ensuring temperature control. Their expansion valves control flow of refrigerant and regulate freezing capacity of system. They feature filtration system to remove particulates and impurities from solution. Our Recirculating Chiller is applicable for automotive testing, electronics, medical and pharmaceutical equipment.








The Recirculating Chillers LRC-L14 is built with noise-conscious components, including a vibration-reduced compressor and an acoustically managed internal frame. Its airflow path is directed laterally to reduce echo in confined spaces. The fan operates based on load, preventing constant high-speed cycling. This keeps the sound profile low even during extended operation. Our chiller suits quiet zones like research labs or instrument rooms. It can be placed near sensitive equipment without disrupting users. Unlike traditional models, it avoids harsh resonance during temperature recovery. This makes it ideal for uninterrupted lab environments.
The Recirculating Chillers LRC-L14 is structured for adaptability in space-constrained labs or equipment racks. Its upright build and low horizontal footprint allow installation beside tall systems like bioreactors or test chambers. The airflow is expelled sideways, avoiding direct vertical ventilation conflicts. Our chiller supports close-coupled positioning without overheating concerns. The non-slip bottom structure and cable routing setup enhance usability in clustered spaces. With handles placed at the side, shifting and anchoring becomes manageable. This makes the unit ideal for labs that must stack or cluster tools. It fits workflows that need maximum performance in compact layouts.
The Recirculating Chillers LRC-L14 is equipped with safeguards that address electrical instability in lab environments. Its compressor is protected with delayed restart logic, preventing sudden cycles after a brief outage. The overload and thermal cutoff features further insulate the system from irregular currents. Our chiller also uses shielded components to isolate internal circuits from surges. These design elements help maintain consistent functionality even in labs with varying voltage levels. If instability occurs, safety responses activate without operator intervention. These safeguards cooling tasks and protects adjacent connected instruments. The protection is designed to ensure uninterrupted cooling flow.
Our Recirculating Chillers LRC-L14 is suitable for extended or shift-based operations in demanding lab or industrial applications. The robust cooling power output supports devices that run without pause, such as simulation units or pilot reactors. Its internal components are shielded from temperature fatigue with layered protections. The system’s closed circulation and air-cooling assembly reduce wear even under prolonged demand. The durable housing resists environmental stress in busy lab settings. With stable flow regulation and smart circuit design, interruptions are rare. The construction ensures efficient performance in nonstop use scenarios. This makes it compatible with high-throughput thermal setups.
Our Recirculating Chillers LRC-L14 can be paired with automated systems due to its stable output flow and predictable thermal performance. It delivers reliable circulation needed for programmable test benches, sample cooling, or material control stations. The consistent fluid return rate ensures synchronized temperature handling. Its non-networked operation makes it compatible with independent sensors or external monitoring. The footprint allows simple physical integration into automated enclosures. No frequent intervention is required once initiated. This makes it suitable for environments where remote workflows are followed. It supports repetitive cycles in research automation setups.
Labtron’s Recirculating Chillers LRC-L14 incorporates a fully enclosed fluid system that minimizes loss due to evaporation or contamination. The tubing materials used inside the circulation route are designed for chemical compatibility and low permeability. Our design eliminates open exposure of the working fluid during use. In longer processes, this avoids degradation or changes in composition. The top-fill design also prevents spills during refill. Operators can refill or monitor levels without opening the system. The fluid remains clean even during frequent use. This helps maintain coolant stability across multiple lab cycles.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608