| Temperature Range | –20 to 25°C |
| Temperature Control Accuracy | ±2°C |
| Ambient Temperature | 5 to 35°C |
| Cooling Method | Air cooling |
| Cooling Capacity at 0°C | 1650 W |
| Cooling Capacity at –10°C | 950 W |
| Cooling Capacity at –20°C | 500 W |
| Rated Pump Flow Rate | 20 L/min |
| Rated Pump Power | 0.4 bar |
| Outer Circulation Interface Size | Rc 1/2 |
| Reservoir Capacity: | 10 L |
| Protection Grade | IP20 |
| Power Supply | 220 to 240 V, 50 Hz |
| Power Consumption | 1280 W |
| Dimensions (W×D×H) | 435 × 690 × 720 mm |
| Net Weight | 70 kg |
Shock-dampened structural alignment
Contaminant-blocking air intake
Maintenance-guided diagnostic indicators
Pressure-equalizing expansion buffer
Circuit-stabilized output regulation
Recirculating Chiller LRC-L11 functions as an external cooling unit for laboratory instruments and pilot-scale systems requiring consistent circulation. That makes it suitable for applications such as bioreactor support, evaporator condenser cooling, and temperature regulation in material testing environments.
Download catalog for
Recirculating Chillers LRC-L11 Catalog
Available Range :
Recirculating Chiller LRC-F10 : -100°C to 90°C Recirculating Chiller LRC-A12 : -20 ℃ to RT Recirculating Chiller LRC-L10 : -20°C to RT Recirculating Chiller LRC-A11 : -20℃ to RT Recirculating Chiller LRC-C10 : -25°C to 90°C Recirculating Chiller LRC-D10 : -45°C to 90°C Recirculating Chiller LRC-E10 : -80°C to 90°C Recirculating Chiller LRC-B10 : 5°C to 90°C Recirculating Chiller LRC-A10 : 5˚C to 40˚C Recirculating Chillers LRC-L11 : –20 to 25°C Recirculating Chillers LRC-L12 : –30 to 5°CLabtron Recirculating Chiller provide cooling of fluids from -5℃ to 40℃ by circulating them through system to remove heat. They include evaporators to absorb thermal energy from liquid ensuring temperature control. Their expansion valves control flow of refrigerant and regulate freezing capacity of system. They feature filtration system to remove particulates and impurities from solution. Our Recirculating Chiller is applicable for automotive testing, electronics, medical and pharmaceutical equipment.








Recirculating Chiller LRC-L11 is suitable for shared lab spaces where multiple teams depend on consistent access to external cooling. Its output remains stable even with shifting workloads, making it dependable across back-to-back tasks. The unit handles variable timing without requiring repeated adjustments. It accommodates frequent use without compromising cooling continuity. Structural insulation also minimizes sound disturbance across nearby stations. Our chiller fits shared academic, industrial, and collaborative research environments. That adaptability supports busy labs with parallel workflows. This makes it a robust addition to multi-user facilities.
Labtron’s Recirculating Chiller LRC-L11 has a structure built with lab space in mind. Its base layout and frame support stable operation without requiring excess clearance. The footprint allows for easy integration beneath lab benches or alongside processing units. Ventilation is positioned to maximize performance without crowding. The caster setup also supports relocation if workstations are restructured. All access points are designed for front-facing operation to limit unnecessary reach. That makes this chiller ideal for both compact labs and modular pilot plants. The build supports productivity in confined working zones.
The Recirculating Chiller LRC-L11 is designed to interface with more than one system simultaneously. The flow output and port access allow it to connect to evaporators, reactors, or thermal testing chambers in parallel configurations. That functionality reduces the need for multiple individual chillers in process labs. It helps consolidate thermal control systems into a single compact footprint. Cooling distribution remains balanced due to optimized internal channelling. Our chiller also includes fittings that adapt well to variable tubing connections. Multi-station compatibility helps scale lab productivity. It’s particularly useful for test benches supporting mixed instrument loads.
The Recirculating Chiller LRC-L11 includes built-in safeguards to manage fluid use without spills or contamination. A fully enclosed path limits air exposure, keeping the coolant clean throughout repeated cycles. Drainage and filling points are isolated and easy to access, reducing handling effort. The real-time level monitoring helps avoid overfilling or dry running. Leak-related issues are minimized due to sealing at all fluid interface points. The user does not require constant fluid checks during longer operations. Our unit simplifies controlled fluid use across standard and specialized lab settings. This makes it better suited for critical applications.
Our Recirculating Chiller LRC-L11 is built with mobility considerations. Its frame includes stable caster wheels that support movement without tipping or leakage. The outer structure absorbs minor bumps without damage during repositioning. Weight distribution helps prevent stress on key components when rolled. Handle placements are aligned with safe lifting zones. Relocation can be done without system disassembly. That makes it ideal for labs where equipment layout shifts frequently. Flexibility in movement extends the chiller’s usefulness beyond permanent installations.
Our Recirculating Chiller LRC-L11 includes features that help preserve the integrity of the circulating fluid over extended sessions. The fully enclosed design shields the liquid from environmental exposure that could lead to contamination. Each fluid contact point is designed for resistance to breakdown from repeated cycling. No exposed areas allow vapor escape or fluid degradation. This closed-loop structure supports consistency across continuous runs. The setup is useful in workflows requiring fluid stability over many hours. That protection extends coolant service life. It’s built to support longevity in active lab conditions.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608