Request A Quote
Recirculating Chillers LRC-L16

Recirculating Chillers LRC-L16

Recirculating Chillers LRC-L16 operates within a wide temperature range, ensuring compatibility with temperature-sensitive setups. Its rotatable circulation nozzle supports flexible alignment with external lab equipment. The built-in compressor delay feature helps prevent mechanical wear and extends component life by reducing the impact of frequent restarts. Our Chillers supports rotary evaporators and analysers as a stable cooling source.

Recirculating Chillers LRC-L16 FRONT VIEW
Recirculating Chillers LRC-L16 SIDE VIEW
Recirculating Chillers LRC-L16 BACK VIEW
Request Quote
Working Temperature Range -15~25 °C
Ambient Temperature 5 to 35°C
Temperature stability ±2 °C
Cooling method Air cooling
Cooling capacity at 0 °C 400 W
Refrigerant R134A
Protection grade IP20
Rated pump pressure 0.2 bar
Pump flow rate 17 L/min
Outer circulation interface ODΦ10 Pagoda type
Reservoir capacity 3 L
Power Consumption 450 W
Power supply 220–240 V~, 50 Hz
Dimensions (W × D × H) 260 × 410 × 550 mm
Net Weight 26 kg
  • Corrosion-resistant internal tubing

  • Silent operation compressor unit

  • Low-maintenance system design

  • Leak-proof fluid enclosure

  • Foam-insulated fluid chamber

Recirculating Chillers LRC-L16 serves as a reliable external cooling source for various laboratory instruments. This compact chiller is particularly suited for pairing with rotary evaporators and analysers, offering steady thermal control during extended operations.

Models of Recirculating Chiller

Labtron Recirculating Chiller provide cooling of fluids from -5℃ to 40℃ by circulating them through system to remove heat. They include evaporators to absorb thermal energy from liquid ensuring temperature control. Their expansion valves control flow of refrigerant and regulate freezing capacity of system. They feature filtration system to remove particulates and impurities from solution. Our Recirculating Chiller is applicable for automotive testing, electronics, medical and pharmaceutical equipment.

Recirculating Chiller LRC-D16

Recirculating Chiller LRC-D16

  • Temperature Range : -45°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 35L
  • Fluid Volume : 20L Internal Circulation
Recirculating Chiller LRC-C16

Recirculating Chiller LRC-C16

  • Temperature Range : -25°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 35L
  • Fluid Volume : 20L Internal Circulating
Recirculating Chillers LRC-L14

Recirculating Chillers LRC-L14

  • Temperature Range : –30 to 5°C
  • Temperature Control Accuracy : ±2°C
  • Ambient Temperature : 5 to 35°C
  • Cooling Method : Air cooling
Recirculating Chiller LRC-L15
Recirculating Chiller LRC-L15
  • Temperature Range : –30 to 5°C
  • Temperature Control Accuracy : ±2°C
  • Ambient Temperature : 5 to 35°C
  • Cooling Method : Air cooling
Recirculating Chiller LRC-E12
Recirculating Chiller LRC-E12
  • Temperature Range : -80°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 15L
  • Fluid Volume : 6L Internal Circulation
Recirculating Chiller LRC-F10

Recirculating Chiller LRC-F10

  • Temperature Range : -100°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 10L
  • Fluid Volume : 5L Internal Circulation
Recirculating Chiller LRC-F11

Recirculating Chiller LRC-F11

  • Temperature Range : -100°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 15L
  • Fluid Volume : 8L Internal Circulation
Recirculating Chiller LRC-C13

Recirculating Chiller LRC-C13

  • Temperature Range : -25°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 15L
  • Fluid Volume : 8L Internal Circulation
Recirculating Chillers LRC-L16 FAQ's
  • Our Recirculating Chillers LRC-L16 is designed with a small footprint and rotatable circulation nozzle, making it suitable for tight bench spaces. Its adaptable structure allows users to align it closely with small rotary evaporators or analyzers. This feature prevents space conflicts in crowded environments. Integration with vertical or side-mounted setups becomes easier without reconfiguring the entire workspace. Users working in constrained environments can benefit from its space-saving orientation. The physical design focuses on mobility without sacrificing functionality. Equipment layout changes can be accommodated without disconnecting hoses. This makes it an ideal fit for dynamic lab configurations.

  • Labtron's Recirculating Chillers LRC-L16 features compressor delay start and overload safeguards, enabling stable use throughout extended operations. These protections reduce mechanical strain during frequent start-stop cycles often seen in long-duration lab processes. By controlling the cooling cycle's response time, component wear is minimized. Labs operating continuously can depend on this reliability to avoid mid-process breakdowns. Consistent system readiness is especially useful when paired with analysers or multi-stage evaporation systems. The unit prevents thermal shocks during restarts. Its internal protection design supports round-the-clock performance. Operational continuity is prioritized without requiring frequent oversight.

  • Our Recirculating Chillers LRC-L16 comes with a 360° rotatable circulation outlet, allowing diverse alignment options during equipment setup. Whether connecting to top-loading or side-inlet systems, the nozzle positioning ensures adaptability across instruments. This feature eliminates the need for angled tubing or bending joints. Compatibility with various device orientations simplifies installation. Tubing arrangements stay secure and stress-free even when repositioned. Technicians can switch connections between different lab modules without hardware changes. It supports workflows involving interchangeable glassware systems. Setup time and equipment movement are significantly reduced as a result.

  • The Labtron's Recirculating Chillers LRC-L16 is built to support rotary evaporators by providing consistent low-temperature coolant output during evaporation cycles. This helps control vapour condensation efficiency without requiring recalibration of external devices. Sudden temperature jumps that affect distillation yields are avoided. Its output maintains enough cooling to stabilize sensitive evaporative operations. Users processing volatile solvents benefit from its dependable thermal backing. Its compatibility extends beyond evaporation and supports similar cooling-demanding tasks. The chiller remains responsive during peak solvent recovery stages. This ensures that product integrity is maintained throughout.

  • The Labtron's Recirculating Chillers LRC-L16 includes layered protection mechanisms like thermal overload control, enhancing its operational lifespan. This design limits exposure to stress conditions that typically damage cooling equipment over time. The chiller is shielded from voltage surges or inconsistent electrical input, often encountered in shared power environments. Hardware fatigue is slowed down due to controlled startup routines. Extended use doesn’t translate to frequent part replacement. Lab users looking for long-term reliability benefit from its self-protective features. Its robust housing and safeguarded internal circuits support year-round usage. Downtime due to internal failures is significantly minimized.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.