Recirculating Chiller LRC-L15 offers a temperature range of –30 to 5°C, suitable for low-temperature operations in laboratory and industrial setups. Its high-capacity reservoir reduces refill frequency during extended cooling use. The air-cooled system lowers maintenance and simplifies setup across environments. Our recirculating chiller supports applications such as bioreactor cooling, material testing, and semiconductor temperature control.

Recirculating Chiller LRC-L15
Recirculating Chiller LRC-L15
Request Quote
Temperature Range –30 to 5°C
Temperature Control Accuracy ±2°C
Ambient Temperature 5 to 35°C
Cooling Method Air cooling
Cooling Capacity at 0°C 6000 W
Cooling Capacity at –10°C 4000 W
Cooling Capacity at –20°C 2500 W
Cooling Capacity at –25°C 1100 W
Refrigerant R404A
Rated Pump Flow Rate 30 L/min
Rated Pump Power 1 bar
Outer Circulation Interface Size Rc 3/4
Reservoir Capacity 40 L
Protection Grade IP20
Power Supply 220 to 240 V, 50 Hz
Power Consumption 2820 W
Dimensions (W×D×H) 650 × 1055 × 1070 mm
Net Weight 195 kg
  • Insulated process contact tubing

  • Quick-disconnect hose fittings

  • Rear-positioned exhaust outlets

  • Service-friendly access panels

  • Shock-absorbing caster wheels

Recirculating Chiller LRC-L15 provides reliable cooling support for external devices used in laboratory and industrial settings. This ensures consistent temperature control in processes involving condensers, reactors, and precision instruments.

Models of Recirculating Chiller

Labtron Recirculating Chiller provide cooling of fluids from -5℃ to 40℃ by circulating them through system to remove heat. They include evaporators to absorb thermal energy from liquid ensuring temperature control. Their expansion valves control flow of refrigerant and regulate freezing capacity of system. They feature filtration system to remove particulates and impurities from solution. Our Recirculating Chiller is applicable for automotive testing, electronics, medical and pharmaceutical equipment.

Recirculating Chiller LRC-E12

Recirculating Chiller LRC-E12

  • Temperature Range : -80°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 15L
  • Fluid Volume : 6L Internal Circulation
Recirculating Chiller LRC-C11

Recirculating Chiller LRC-C11

  • Temperature Range : -25°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 10L
  • Fluid Volume : 5L Internal Circulating
Recirculating Chiller LRC-E11

Recirculating Chiller LRC-E11

  • Temperature Range : -80°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 10L
  • Fluid Volume : 5L Internal Circulation
Recirculating Chillers LRC-L13
Recirculating Chillers LRC-L13
  • Temperature Range : –30 to 5°C
  • Temperature Control Accuracy : ±2°C
  • Ambient Temperature : 5 to 35°C
  • Cooling Method : Air cooling
Recirculating Chiller LRC-A12
Recirculating Chiller LRC-A12
  • Temperature Range : -20 ℃ to RT
  • Temperature Accuracy : ± 1℃
  • Ambient Temperature : ≤ 30℃
  • Optimum Ambient Humidity : 0.6
Recirculating Chillers LRC-L16

Recirculating Chillers LRC-L16

  • Working Temperature Range : -15~25 °C
  • Ambient Temperature : 5 to 35°C
  • Temperature stability : ±2 °C
  • Cooling method : Air cooling
Recirculating Chiller LRC-C16

Recirculating Chiller LRC-C16

  • Temperature Range : -25°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 35L
  • Fluid Volume : 20L Internal Circulating
Recirculating Chiller LRC-D14

Recirculating Chiller LRC-D14

  • Temperature Range : -45°C to 90°C
  • Temperature Control : ±0.05°C
  • Expansion Tank Volume : 20L
  • Fluid Volume : 10L Internal Circulation
Recirculating Chiller LRC-L15 FAQ's
  • Our Recirculating Chiller LRC-L15 is engineered to run safely alongside precision lab instruments without interference. Its body construction reduces signal disturbance, keeping nearby analytical tools unaffected. Vibration control limits physical disruption to sensitive testing setups. Rear exhaust placement directs warm air away from working zones. This design ensures the chiller can be used even in compact environments. No special shielding or distance buffers are required during use. Instruments remain stable even under continuous cooling operation. This supports labs that require tight equipment integration without layout compromise.

  • Labtron’s Recirculating Chiller LRC-L15 includes safeguards that prevent sudden temperature surges during operation. Compressor delay functions reduce internal stress when restarting after interruptions. The unit helps maintain gradual temperature changes during reactive experiments. Volatile materials remain protected from unintended thermal spikes. System behaviour remains steady even under fluctuating cooling demands. Heat-sensitive tests can proceed without disruption or manual intervention. Built-in safety logic adds a layer of operational reliability. This helps preserve process stability in demanding lab environments.

  • The Recirculating Chiller LRC-L15 is built with space efficiency in mind for constrained lab layouts. Rear venting allows close placement against walls without airflow restriction. Lifting handles and caster wheels simplify relocation during layout changes. Side-mounted ports reduce interference with neighboring instruments. The unit requires no floor mounting or wall support for installation. Equipment can be moved or serviced without disconnecting primary systems. This flexibility benefits labs with evolving project needs. Compact workspaces gain reliable cooling without permanent infrastructure updates.

  • Our Recirculating Chiller LRC-L15 supports workflows that involve dynamic temperature shifts during test cycles. Cooling delivery remains consistent throughout fluctuating stages of a material trial. The system’s circulation behavior avoids temperature drop or fluid lag. This stability is critical for collecting repeatable thermal response data. Researchers can simulate environmental changes with dependable temperature alignment. Built-in safeguards protect the equipment during stress-based testing. Extended trials run without interruption or performance loss. This capability fits well within simulation-heavy laboratory settings.

  • The Recirculating Chiller LRC-L15 uses a fully closed system to retain coolant over long operating periods. Fluid does not evaporate easily, reducing refill interruptions during ongoing testing. Energy is conserved through targeted thermal flow control. No external plumbing or chilled water supply is required for operation. Material waste is minimized, supporting resource-conscious labs. Scheduled maintenance cycles are also reduced due to internal system durability. Consistent performance reduces the need for backup cooling solutions. This enables cost-effective thermal control in daily workflows.

  • Labtron’s Recirculating Chiller LRC-L15 maintains fluid purity by isolating it from external exposure. Its closed-loop circulation prevents contamination by dust, air, or moisture. Coolant properties remain intact over extended periods of use. This protects internal components from corrosion or buildup. Fewer replacements are needed across long operation schedules. Thermal conductivity remains stable during repeated experiments. Lab teams can rely on consistent temperature control with minimal intervention. This extends the usable life of the coolant and the system itself.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.