| Type | Benchtop System |
| Water Requirements | Tap Water |
| Feed Water Conductivity | < 2000 µS/cm |
| Feed Water Hardness | < 450 ppm as CaCO3 |
| Feed Water Temperature | 5°C to 40°C |
| Water Inlet Pressure | 0.05 to 0.5 MPa |
| Ion Rejection Rate | > 95% |
| Bacterial Rejection | > 99% |
| Water Conductivity | < 1 to 20 µS/cm |
| Productivity Rate | 15 L/h |
| Power Supply | 110 V to 220 V / 50 HZ to 60 HZ ± 10% |
| Dimensions (Main Unit) | 315 × 525 × 570 mm |
| Dimensions (Water Tank) | 380 × 380 × 595 mm |
| Net Weight (Main Unit) | 21 Kg |
| Net Weight (Water Tank) | 5 Kg |
Long-Lasting Construction
Advanced Control System
Superior Filtration Technology
Optimized Storage Solution
Stable Output Quality
Our Type II RO water purification system provides high-quality water suitable for ultrapure system feed, chemical processing, glassware cleaning, autoclave supply, buffer preparation, and various laboratory and industrial applications.
Pretreatment cartridge
High pressure pump
Reverse osmosis module
254 single wavelength UV lamp
Micro filter
30L Multifunctional water tank
Water leakage detection
Pretreatment module
Purification cartridge dual column
Ultra-purification cartridge dual column
Ultra-purification cartridge single column
Point-of-use filter (General)
Point-of-use filter
Point-of-use bio filter
30L multifunctional water tank with integrated UV lamp & air vent
60L multifunctional water tank integrated UV lamp & air vent
Strengthened pretreatment module
Strengthened pretreatment cartridge column PP cotton
Strengthened pretreatment cartridge column active carbon
Micro filter (General)
24V UV sterilization lamp for water tank
254/185nm dual wavelength UV lamp
100G Reverse osmosis module
200G Reverse osmosis module
Labtron Type II RO Water Purification System offers a reliable output of pure water, rangingfrom ≥ 10 to ≥ 50 L/hr. Utilizing cutting-edge single and double pass RO processes, thesedeliver ultrapure water at rates of ≥1-1.5 L/min. They feature tank capacities of 30 or 80 L toeffectively accommodate your operational requirements. With TOC under 20 ppb and heavymetals below 0.01 ppm, they ensure exceptional purity. Our Water Purification System areavailable in both benchtop and floor-standing configurations for optimal performance.








Yes, the Type II RO Water Purification System LTWP-D10 is engineered to operate effectively with standard municipal tap water. Its advanced reverse osmosis membranes efficiently reduce ionic, microbial, and particulate contaminants, even when the feed water quality fluctuates within specified limits. The system is equipped to handle feed water conductivity typical of tap supplies, ensuring consistent output. However, if the source water exceeds certain hardness or conductivity thresholds, additional pretreatment may be recommended to protect the membranes. The design prioritizes stable water production regardless of minor variations in source water. This reliability makes the system suitable for use in various geographical regions and conditions.
The Type II RO Water Purification System LTWP-D10 is designed with energy efficiency in mind, helping users reduce operational costs without compromising performance. It optimizes power consumption during the purification process, making it suitable for laboratories and facilities conscious of energy usage. The system’s components, including the pump and electronics, are selected for low power draw while maintaining high rejection rates. This balance of efficiency and performance ensures consistent water quality with minimal environmental impact. Additionally, its compact size contributes to efficient resource use by minimizing space and energy demands. Overall, the system supports sustainable laboratory practices.
The Type II RO Water Purification System LTWP-D10 contributes to laboratory safety by ensuring the consistent supply of pure water that meets quality standards for various processes. Stable water purity helps prevent contamination of sensitive instruments, reagents, and experiments. The system’s durable construction reduces the risk of leaks or failures that could disrupt lab operations. Its user-friendly design also minimizes handling errors during maintenance or operation. Clear indicators and safety features, such as low-pressure protection, help maintain safe and reliable performance. Together, these features support a secure working environment in the lab.
The Type II RO Water Purification System LTWP-D10 helps reduce costs through its energy-efficient operation and low-maintenance design. The long-lasting components and durable construction minimize the need for frequent replacements or repairs. Its tool-free maintenance further saves on service costs and downtime. By providing consistent Type III water quality, it protects downstream equipment and processes from contamination, avoiding costly failures. The compact design also reduces space requirements, which can be valuable in high-cost laboratory environments. All these factors combine to offer long-term value and cost efficiency.
The Type II RO Water Purification System LTWP-D10 features a compact benchtop design, making it ideal for labs with limited space. It uses advanced reverse osmosis technology for reliable Type III pure water production. The system achieves high ionic and bacterial rejection to maintain consistent water quality. Its user-friendly interface and tool-free maintenance simplify daily operation and servicing. Built for durability, the unit ensures long-term performance even under regular use. These key features make it suitable for a variety of laboratory and industrial applications.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608