Vertical Electrophoresis System LVES-B16

Vertical Electrophoresis System LVES-B16

Vertical Electrophoresis System LVES-B16 has a glass plate dimension of 100 × 100 mm, offering a reliable platform for accurate electrophoresis. It provides precise voltage control, ensuring optimal conditions for consistent results. The design guarantees stable gel migration, minimizing distortions and maintaining uniform separation. Its seamless lid-locking mechanism enhances safety by preventing accidental spills or leaks. Our system allows for easy post-run cleanup, ensuring hassle-free maintenance and durability.

Vertical Electrophoresis System LVES-B16
Vertical Electrophoresis System LVES-B16
Vertical Electrophoresis System LVES-B16
Vertical Electrophoresis System LVES-B16-01
Vertical Electrophoresis System LVES-B16-02
Vertical Electrophoresis System LVES-B16-03
Request Quote
Glass Plate Dimensions 100 × 100 mm
Gel Dimensions 82 × 88 mm
Gel Thickness 1.0 mm, 1.5 mm
Number of Gels 1 to 4 pcs
Maximum Buffer Volume 1000 ml
Sample Throughput 11 to 60
Dimension (L × W × H) 220 × 170 × 120 mm
Weight 2.5 kg
  • Visual Progress Monitoring

  • Low Noise Operation

  • Reduced Buffer Wastage 

  • Energy-Efficient System Design

  • Compatible with Multiple Buffers

Vertical Electrophoresis System LVES-B16 is used to separate proteins or nucleic acids based on their size and charge through a vertical gel matrix. It is used in molecular biology, and clinical research for protein analysis, DNA/RNA separation, and genetic studies.

Models of Vertical Electrophoresis System

Labtron Vertical Electrophoresis System integrates advanced cooling system for optimal separation of large number of samples. Their buffer tanks maintain pH and conductivity essential for efficient procedure. They feature combs that create wells for sample loading in gel matrix. Their temperature control mechanisms prevent overheating during prolonged runs. Our Vertical Electrophoresis System is preferred for protein separation, western blotting and genetic fingerprinting.

Vertical Electrophoresis System LVES-B10

Vertical Electrophoresis System LVES-B10

  • Glass Plate Dimensions : 216 × 110 mm
  • Gel Dimensions : 186 × 95 mm
  • Gel Thickness : 1.0 mm
  • Number of Gels : 1 to 2 pcs
Vertical Electrophoresis System LVES-A12

Vertical Electrophoresis System LVES-A12

  • Glass plate size : 100 × 100 mm
  • Gel size : 82 × 88 mm
  • Gel thickness : 1.0, 1.5 mm
  • Number of gel : 1 to 4 pcs
Vertical Electrophoresis System LVES-A10

Vertical Electrophoresis System LVES-A10

  • Glass tray (W × L) : Thick type: 101 × 83 mmThin type : 101 × 73 mm
  • Gel trays (W × L) : Hand glue: 83 × 73 mmPrecast glue: 86 × 68 mm
  • Comb Thickness : Standard : 1.0 mm
  • Buffer Volume : 700 ml
Vertical Electrophoresis System LVES-B17
Vertical Electrophoresis System LVES-B17
  • Glass Plate Dimensions : 100 × 100 mm
  • Gel Dimensions : 82 × 88 mm
  • Gel Thickness : 0.75 mm, 1.0 mm, 1.5 mm
  • Number of Gels : 1 to 2 pcs
Vertical Electrophoresis System LVES-B12
Vertical Electrophoresis System LVES-B12
  • Glass Plate Dimensions : 216 × 110 mm
  • Gel Dimensions : 186 × 95 mm
  • Gel Thickness : 1.0 mm
  • Number of Gels : 1 to 2 pcs
Vertical Electrophoresis System LVES-B13

Vertical Electrophoresis System LVES-B13

  • Glass Plate Dimensions : 216 × 220 mm
  • Gel Dimensions : 186 × 205 mm
  • Gel Thickness : 1.0 mm
  • Number of Gels : 1 to 2 pcs
Vertical Electrophoresis System LVES-B14

Vertical Electrophoresis System LVES-B14

  • Glass Plate Dimensions : 200 × 200 mm
  • Gel Dimensions : 162 × 175 mm
  • Gel Thickness : 1.0 mm
  • Number of Gels : 1 to 2 pcs
Vertical Electrophoresis System LVES-A13

Vertical Electrophoresis System LVES-A13

  • Glass Trays (W× L) : Thick Type: 101 × 83 mm, Thin Type: 101 × 73 mm
  • Gel Trays (W× L) : Hand Glue: 83 × 73 mm, Precast Glue: 86 × 68 mm
  • Comb Thickness : Standard 1 mm, 0.75 mm & 1.5 mm optional
  • Comb Throughput : 10, 15 samples
Vertical Electrophoresis System LVES-B16 FAQ's
  • Labtron’s Vertical Electrophoresis System is equipped with a stable power supply unit that protects the system from sudden voltage fluctuations, ensuring uninterrupted electrophoresis. The system has built-in safeguards that automatically adjust the current and voltage to maintain consistent conditions, preventing sample degradation or band distortion. Labtron recommends using a surge protector to further safeguard the equipment during prolonged use, especially in regions prone to power instability.

  • Yes, Labtron’s Vertical Electrophoresis System is versatile and adaptable for analyzing various sample types, including DNA, RNA, and proteins. The system supports different gel types, such as polyacrylamide for protein separation and agarose for nucleic acid analysis. Labtron provides protocols and guidelines to help researchers optimize gel preparation and running conditions for different sample types, ensuring high-quality and reproducible results.

  • To achieve high-resolution separation of large proteins, Labtron’s Vertical Electrophoresis System supports the use of lower acrylamide concentrations and gradient gels that allow smooth migration of high-molecular-weight proteins. The system provides uniform electric fields and maintains optimal buffer conditions to prevent smearing or distortion of large protein bands. Labtron offers guidance on adjusting gel and buffer compositions to improve the resolution of high-molecular-weight proteins effectively.

  • Labtron’s Vertical Electrophoresis System is designed for easy cleaning and maintenance to ensure consistent performance. Electrodes and buffer tanks should be cleaned with deionized water after each use to remove salt deposits and buffer residues. For deeper cleaning, Labtron recommends using a mild detergent solution followed by thorough rinsing. Proper cleaning of these components helps prevent contamination and extends the lifespan of the system.

  • Yes, Labtron’s Vertical Electrophoresis System allows for simultaneous running of multiple gels, which increases throughput and efficiency. The system features dual-gel casting capabilities, enabling researchers to analyze multiple samples under the same conditions. Labtron provides accessories and detailed guidelines for setting up and running multiple gels simultaneously, ensuring consistent and reproducible results across different gels.

  • Labtron’s Vertical Electrophoresis System supports the use of specialized buffers for modified applications, such as native PAGE, denaturing PAGE, and isoelectric focusing. These buffers can be tailored to meet specific experimental goals, such as enhancing separation efficiency or maintaining protein structure. Labtron provides detailed buffer preparation protocols to ensure compatibility with the system, allowing researchers to achieve desired outcomes with customized conditions.

  • Labtron’s Vertical Electrophoresis System incorporates multiple safety features to prevent electrical hazards, including insulated covers, secure clamps, and automatic power cut-off mechanisms in case of an anomaly. The system is designed to protect users from accidental exposure to high voltage while maintaining optimal operational safety. Labtron also provides user guidelines to ensure safe handling and operation of the system.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608