Request A Quote
Analytical HPLC System LAHS-A11

Analytical HPLC System LAHS-A11

Analytical HPLC System LAHS-A11 offers a flow range of 0.001 to 10.000 mL/min (step size 0.001 mL/min). It features intelligent IP address allocation for automatic unit configuration. Its high-quality imported components ensure detector sensitivity and long life. The advanced optical path improves the signal-to-noise ratio. Our system is used for precise chemical and pharmaceutical analysis, quality control, and research applications.

Request Quote
Flow Range 0.001 to 10.000 mL/min (step size 0.001 mL/min)
Flow Rate Accuracy ≤ ±0.2 %
Flow Stability (RSD) ≤ 0.06 %
Maximum Working Pressure 63 MPa
Pump Power Consumption 50 Hz / 100 W
Pump Power Supply AC 220 V ± 10 %
Pump Dimensions (L × W × H) 540 × 400 × 160 mm (L × W × H)
Pump Weight 25 kg
Linear Range ≥ 2.0 AU
Wavelength Range 190 to 800 nm
Baseline Noise ≤ ±0.25 × 10⁻⁵ AU
Baseline Drift ≤ 0.5 × 10⁻⁴ AU
Detector Power Consumption 50 Hz / 100 W
Detector Power Supply AC 220 V ±10 %
Detector Dimensions (L × W × H) 540 × 400 × 160 mm
Detector Weight 16 kg
In-line Degassing Built-in binary or quaternary (optional)
Contact with Liquid Materials PEEK, Teflon® AF
Number of Solvent Bottles Holds up to 6 solvent bottles of 1000 mL capacity
System Organizer Power Consumption 50 Hz / 30 W
System Organizer Power Supply AC 220 V ±10 %
System Organizer Dimensions (L × W × H) 540 × 400 × 120 mm (L × W × H)
System Organizer Weight 10 kg
  • Flexible Gradient Elution
  • Optimised Cam Design
  • Stable Low-Flow Output
  • Plunger Wear Reduction
  • High Sealing Precision

Our Analytical HPLC System is used for precise chemical and pharmaceutical analysis, quality control, and research applications, ensuring separation, detection, and quantification of complex mixtures in laboratories and testing environments.

Sr. NoAccessoriesQuantity
1M5101 system organiser1 unit 
2P5102 high pressure pump (binary gradient)1 unit 
3D5101 UV-Vis Detector1 unit 
4Rheodyne 7725I High pressure six-way injection valve1 set
5VB5101 valve support1 pc 
6Supersil ODS2 5 µm 4.6 × 250 mm1 pc 
7Kromstation chromatography data workstation (basic)1 set
8IChrom5100 system1 set
  • Column oven 
  • Fluorescence Detector

Models of Analytical HPLC

Labtron Analytical HPLC ensure separation of components based on their chemical properties in sample. Their high resolution enhances detection of minute differences in compound concentrations. They employ elevated pressure pump for efficient solvent movement through chromatography column. Their automated sample injection system increases throughput, reducing need for manual handling. Our Analytical HPLC is ideal in pharmaceutical, environmental, and chemical analysis for quality control, research, and regulatory testing.

Analytical HPLC System LAHS-B11

Analytical HPLC System LAHS-B11

  • Pump Type : Double plunger reciprocating pump
  • Pump Sets : 2
  • Flow Range : 0.001 to 10.00 ml/min
  • Pump Setting Step Size : 0.001 ml/min
Analytical HPLC System LAHS-B13

Analytical HPLC System LAHS-B13

  • Pump Type : Dual Binary High-Pressure Pump
  • Solvent Channel : 4
  • Flow Range : 0.001 to 10.000 mL/min
  • Pump Flow Accuracy : Up to ± 0.2 %
Analytical HPLC System LAHS-C10

Analytical HPLC System LAHS-C10

  • Wavelength Range : 190 to 800 nm
  • Pump Flow Range : 0.001 to 10.000 mL/min (step 0.001 mL/min)
  • Gradient Accuracy : Up to ± 1%
  • Retention Time Repeatability : Up to 0.1%
Analytical HPLC System LAHS-D10
Analytical HPLC System LAHS-D10
  • Pump Flow Range : 0.001 to 10.000mL/min
  • Pump Set Step : 0.001mL/min
  • Pump Pressure Range : 0 to 42 MPa
  • Pump Pressure Pulsation : 0.1MPa (10MPa, C18, methanol 1mL/min)
Analytical HPLC System LAHS-B12
Analytical HPLC System LAHS-B12
  • Pump Type : High pressure constant flow pump
  • Solvent Channel : 2
  • Flow Range : 0.001 to 10.000 mL/min
  • Pump Flow Accuracy : Up to ± 0.3 %
Analytical HPLC System LAHS-B10

Analytical HPLC System LAHS-B10

  • Wavelength Range : 190 to 700 nm
  • Pump Type : Double plunger reciprocating pump (1 Set)
  • Flow Range : 0.001 to 10.00 mL/min
  • Setting Step Size : 0.001 mL/min
Analytical HPLC System LAHS-E10

Analytical HPLC System LAHS-E10

  • Flow Rate Setting Range : 0.0000 to 12.0000mL/min
  • Flow Rate Setting Increment : 0.0001mL/min
  • Gradient Error : Less than equal to 0.75%
  • Gradient Stability : 0.2% RSD (5% to 95%, 0.2 to 2.0mL/min)
Analytical HPLC System LAHS-A10

Analytical HPLC System LAHS-A10

  • Pump Type : Quaternary Low-Pressure Pump
  • Pump Flow Rate Range : 0.001 to 10.000 ml/min, in 0.001ml increments
  • Pump Flow Accuracy : ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)
  • Pump Flow Precision : RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5Mpa)

Analytical HPLC:
Analytical HPLC System LAHS-B11, Analytical HPLC System LAHS-B13, Analytical HPLC System LAHS-C10, Analytical HPLC System LAHS-D10, Analytical HPLC System LAHS-B12, Analytical HPLC System LAHS-B10, Analytical HPLC System LAHS-E10, Analytical HPLC System LAHS-A10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.