Analytical HPLC System LAHS-B13 features a Dual Binary High-Pressure Pump with 4 solvent channels. It has 2 detectors that can detect wavelengths from 190 to 800 nm. This detector features an automatic calibration function and can optimize the deuterium lamp energy. The system offers an autosampler with an injection range of up to 100 µL, ensuring highly reproducible injections. Our HPLC system is used in pharmaceuticals and food safety for advanced chromatography applications.

Analytical HPLC System LAHS-B13
Analytical HPLC System LAHS-B13
Analytical HPLC System LAHS-B13
Request Quote
Pump Type Dual Binary High-Pressure Pump
Solvent Channel 4
Flow Range 0.001 to 10.000 mL/min
Pump Flow Accuracy Up to ± 0.2 %
Pump Flow Stability Up to 0.06 %
Pump Maximum Pressure 70 MPa
Pulsation ≤0.1MPa
Detector 1 Photodiode Array Detector
Detector 1 Light source Deuterium lamp
Detector 1 Wavelength range 190 to 800nm
Detector 1 Wavelength repeatability ≤0.1nm
Detector 1 Wavelength accuracy ±1nm
Detector 1 Spectral resolution 1.2 nm
Detector 1 Frequency 5Hz
Detector 1 Noise ≤±1.0×10-5AU
Detector 1 Drift ≤2×10-4AU/h
Detector 1 Linearity range ≥2.0AU
Detector 1: Maximum backpressure on the flow cell ≤8MPa
Detector 2 UV-visible detector
Detector 2 Light source Deuterium lamp, Tungsten lamp
Detector 2 Wavelength range 190 to 800 nm
Detector 2 Wavelength repeatability ≤0.1 nm
Detector 2 Wavelength accuracy ±1nm
Detector 2 Path length 10 mm
Detector 2 Noise ≤±1.5×10-5AU
Detector 2 Drift ≤2.0×10-4AU/h
Detector 2 Linearity range ≥2.0AU
Detector 2: Maximum backpressure on the flow cell ≤8MPa
Autosampler Injection Range 0 to100 µL
Autosampler Precision RSD<0.2%
Autosampler Sample Residue <0.005%
Autosampler Linearity R2>0.999
Column Oven Temperature Range RT+5℃-80℃
Column Oven Temperature Accuracy 0.1℃
Column Oven Temperature Stability 0.1℃
Standard Software Chromatographic Data-processing workstation
Other Standard Accessories Solvent tray, system tool kit, 1000 mL Solvent Bottles (4)
  • High-pressure pumping
  • Stable temperature control
  • Low-noise performance
  • Wide flow range
  • Accurate wavelength control
  • High spectral resolution
  • Excellent linearity

Our Analytical HPLC System LAHS-B13 is used for precise separation and quantification of complex mixtures due to its high-pressure pumping. It is widely used in pharmaceutical quality control, food safety analysis, and academic laboratories.

Models of Analytical HPLC

Labtron Analytical HPLC ensure separation of components based on their chemical properties in sample. Their high resolution enhances detection of minute differences in compound concentrations. They employ elevated pressure pump for efficient solvent movement through chromatography column. Their automated sample injection system increases throughput, reducing need for manual handling. Our Analytical HPLC is ideal in pharmaceutical, environmental, and chemical analysis for quality control, research, and regulatory testing.

Analytical HPLC System LAHS-B12

Analytical HPLC System LAHS-B12

  • Pump Type : High pressure constant flow pump
  • Solvent Channel : 2
  • Flow Range : 0.001 to 10.000 mL/min
  • Pump Flow Accuracy : Up to ± 0.3 %
Analytical HPLC System LAHS-E10

Analytical HPLC System LAHS-E10

  • Flow Rate Setting Range : 0.0000 to 12.0000mL/min
  • Flow Rate Setting Increment : 0.0001mL/min
  • Gradient Error : Less than equal to 0.75%
  • Gradient Stability : 0.2% RSD (5% to 95%, 0.2 to 2.0mL/min)
Analytical HPLC System LAHS-D10

Analytical HPLC System LAHS-D10

  • Pump Flow Range : 0.001 to 10.000mL/min
  • Pump Set Step : 0.001mL/min
  • Pump Pressure Range : 0 to 42 MPa
  • Pump Pressure Pulsation : 0.1MPa (10MPa, C18, methanol 1mL/min)
Analytical HPLC System LAHS-A11
Analytical HPLC System LAHS-A11
  • Flow Range : 0.001 to 10.000 mL/min (step size 0.001 mL/min)
  • Flow Rate Accuracy : ≤ ±0.2 %
  • Flow Stability (RSD) : ≤ 0.06 %
  • Maximum Working Pressure : 63 MPa
Analytical HPLC System LAHS-C10
Analytical HPLC System LAHS-C10
  • Wavelength Range : 190 to 800 nm
  • Pump Flow Range : 0.001 to 10.000 mL/min (step 0.001 mL/min)
  • Gradient Accuracy : Up to ± 1%
  • Retention Time Repeatability : Up to 0.1%
Analytical HPLC System LAHS-A10

Analytical HPLC System LAHS-A10

  • Pump Type : Quaternary Low-Pressure Pump
  • Pump Flow Rate Range : 0.001 to 10.000 ml/min, in 0.001ml increments
  • Pump Flow Accuracy : ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)
  • Pump Flow Precision : RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5Mpa)
Analytical HPLC System LAHS-B11

Analytical HPLC System LAHS-B11

  • Pump Type : Double plunger reciprocating pump
  • Pump Sets : 2
  • Flow Range : 0.001 to 10.00 ml/min
  • Pump Setting Step Size : 0.001 ml/min
Analytical HPLC System LAHS-B10

Analytical HPLC System LAHS-B10

  • Wavelength Range : 190 to 700 nm
  • Pump Type : Double plunger reciprocating pump (1 Set)
  • Flow Range : 0.001 to 10.00 mL/min
  • Setting Step Size : 0.001 mL/min

Analytical HPLC:
Analytical HPLC System LAHS-B12, Analytical HPLC System LAHS-E10, Analytical HPLC System LAHS-D10, Analytical HPLC System LAHS-A11, Analytical HPLC System LAHS-C10, Analytical HPLC System LAHS-A10, Analytical HPLC System LAHS-B11, Analytical HPLC System LAHS-B10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.