Request A Quote
Analytical HPLC System LAHS-B11

Analytical HPLC System LAHS-B11

Analytical HPLC System LAHS-B11 is a unit equipped with LCD display UV-Visible wavelength range of 190 nm to 700 nm and double plunger reciprocating pump system for constant flow pump. It has gradient kit system for test result accuracy. Consists of separate workstation, sample injector and front mounted self-locking switch. Deuterium lamp is used as light source with valve mounting frame. It is ideally used in the detection of compounds in pharmaceutical industries, research institute, food industries, and petroleum industries, etc.

Analytical HPLC System LAHS-B11
Analytical HPLC System LAHS-B11
Request Quote
Pump Type Double plunger reciprocating pump
Pump Sets 2
Flow Range 0.001 to 10.00 ml/min
Pump Setting Step Size 0.001 ml/min
Pump Flow Accuracy ≤ ± 0.3 %
Pump Flow Stability RSD ≤ 00.1 %
Pump Maximum Pressure 42 MPa
Pump Display Pressure Error ≤ 1.0 %
Pump Pressure Fluctuation ≤ 1.0 %
Pump Power Consumption 80 W
Detector Wavelength Range 190 to 700 nm
Detector Wavelength Repeatability ± 0.1 nm
Detector Band Width 8 nm
Detector Response Time 0 to 4.9 seconds
Detector Linearity Range 1.8 AU (5 %)
Detector Baseline Noise ≤ ± 1 × 10-5 AU
Detector Baseline Drift ≤ 2.0 × 10-4 AU/h
Minimum Detectable Concentration 4.0 × 10-9 g/ml
Detector Cell Optical path: 10 mm
Volume: 10 µL
Detector Light Source Deuterium lamp
Detector Power Consumption 100 W
Detector Power Supply AC 110 V/ 220 V ± 10 %, 50/60 Hz
Packing Dimensions (W × D × H) 600 × 440 × 380 mm
Gross Weight 75 kg
  • Double plunger reciprocating pump system
  • Gradient system kits
  • Sample injector: 1 set
  • Deuterium lamp light source
  • Separate workstation
  • LCD display for value observation
  • Front mounted self-locking switch
  • Output: USB port
  • Compact and easy to install

Widely used in pharmaceutical, petroleum, research institute, food industrial applications in separation and detection of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

Models of Analytical HPLC

Labtron Analytical HPLC ensure separation of components based on their chemical properties in sample. Their high resolution enhances detection of minute differences in compound concentrations. They employ elevated pressure pump for efficient solvent movement through chromatography column. Their automated sample injection system increases throughput, reducing need for manual handling. Our Analytical HPLC is ideal in pharmaceutical, environmental, and chemical analysis for quality control, research, and regulatory testing.

Analytical HPLC System LAHS-B12

Analytical HPLC System LAHS-B12

  • Pump Type : High pressure constant flow pump
  • Solvent Channel : 2
  • Flow Range : 0.001 to 10.000 mL/min
  • Pump Flow Accuracy : Up to ± 0.3 %
Analytical HPLC System LAHS-B10

Analytical HPLC System LAHS-B10

  • Wavelength Range : 190 to 700 nm
  • Pump Type : Double plunger reciprocating pump (1 Set)
  • Flow Range : 0.001 to 10.00 mL/min
  • Setting Step Size : 0.001 mL/min
Analytical HPLC System LAHS-A11

Analytical HPLC System LAHS-A11

  • Flow Range : 0.001 to 10.000 mL/min (step size 0.001 mL/min)
  • Flow Rate Accuracy : ≤ ±0.2 %
  • Flow Stability (RSD) : ≤ 0.06 %
  • Maximum Working Pressure : 63 MPa
Analytical HPLC System LAHS-D10
Analytical HPLC System LAHS-D10
  • Pump Flow Range : 0.001 to 10.000mL/min
  • Pump Set Step : 0.001mL/min
  • Pump Pressure Range : 0 to 42 MPa
  • Pump Pressure Pulsation : 0.1MPa (10MPa, C18, methanol 1mL/min)
Analytical HPLC System LAHS-A10
Analytical HPLC System LAHS-A10
  • Pump Type : Quaternary Low-Pressure Pump
  • Pump Flow Rate Range : 0.001 to 10.000 ml/min, in 0.001ml increments
  • Pump Flow Accuracy : ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)
  • Pump Flow Precision : RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5Mpa)
Analytical HPLC System LAHS-C10

Analytical HPLC System LAHS-C10

  • Wavelength Range : 190 to 800 nm
  • Pump Flow Range : 0.001 to 10.000 mL/min (step 0.001 mL/min)
  • Gradient Accuracy : Up to ± 1%
  • Retention Time Repeatability : Up to 0.1%
Analytical HPLC System LAHS-E10

Analytical HPLC System LAHS-E10

  • Flow Rate Setting Range : 0.0000 to 12.0000mL/min
  • Flow Rate Setting Increment : 0.0001mL/min
  • Gradient Error : Less than equal to 0.75%
  • Gradient Stability : 0.2% RSD (5% to 95%, 0.2 to 2.0mL/min)

Analytical HPLC:
Analytical HPLC System LAHS-B12, Analytical HPLC System LAHS-B10, Analytical HPLC System LAHS-A11, Analytical HPLC System LAHS-D10, Analytical HPLC System LAHS-A10, Analytical HPLC System LAHS-C10, Analytical HPLC System LAHS-E10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.