Request A Quote
Automatic Polarimeter LPMR-A31

Automatic Polarimeter LPMR-A31

Automatic Polarimeter LPMR-A31 offers an optical measurement range of 90°, along with an extended range of 259° Z for sugar solutions. It operates at a wavelength of 589.44 nm which detects and measures rotations with high sensitivity. Our polarimeter maintains both heating and cooling conditions and ensures the sample is under consistent temperature. It is equipped with an 8-inch LCD for navigating variable parameters.
Request Quote
Measurement Mode Optical rotation, specific rotation, sugar degree, and concentration (Custom)
Calibration Mode Multi-point automatic calibration
Measuring Range ±90° (Optical Rotation) ± 259° Z (Sugar)
Minimum Reading 0.001°
Accuracy ±0.006°
Repeatability (Standard Deviations) ≤0.002°
Measurable Sample Min. Transmittance 0.001
Light Source Light-emitting diode (LED) + precision interference filters
Working Wavelength 589.44 nm (Sodium D Spectrum)
Test Tube 200 mm, 100 mm (regular)
Display 8-inch color dot matrix touch LCD
Data Storage 240MB
Interface USB/Printer/U disk
21 CFR Part 11 Certification Yes
Power Consumption 250 W
Power Supply AC 220V ± 10% 50 Hz
Dimension (L × W × H) 860 × 510 × 470 mm
Net Weight 33 Kg
Gross Weight 36 Kg
  • Robust construction
  • Multi-point automatic calibration
  • LED light source
  • Supports data storage
Automatic Polarimeter is ideal across various industries including sugar production, pharmaceuticals, petroleum, food, chemicals, and research institutions.

Models of Automatic Polarimeter

Labtron Automatic Polarimeter features built-in Peltier temperature control systems, offering precise readings across various temperatures. They utilize long-life LEDs as their light source, eliminating frequent replacements. Their multiple measurement modes—optical and specific rotation, concentration, and international sugar content give comprehensive analysis. Our Automatic Polarimeter comes with a wide measurement range, coupled with robust data storage and connectivity options.

Automatic Polarimeter LPMR-A44

Automatic Polarimeter LPMR-A44

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm
  • Measuring Fan Tin : +90°
Automatic polarimeter LPMR-A30

Automatic polarimeter LPMR-A30

  • Measurement mode : Four modes: optical rotation, specific rotation, concentration and international sugar content
  • Calibration mode : Automatic Calibration
  • Measuring Range : ±89.99°, ±259°Z
  • Minimum reading : 0.001°(optical rotation)
Automatic Polarimeter LPMR-A41

Automatic Polarimeter LPMR-A41

  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: 259° Z
Automatic Polarimeter LPMR-A40
Automatic Polarimeter LPMR-A40
  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: 259° Z
Automatic Polarimeter LPMR-A43
Automatic Polarimeter LPMR-A43
  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A45

Automatic Polarimeter LPMR-A45

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A46

Automatic Polarimeter LPMR-A46

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A42

Automatic Polarimeter LPMR-A42

  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: ±259°Z

Automatic Polarimeter:
Automatic Polarimeter LPMR-A44, Automatic polarimeter LPMR-A30, Automatic Polarimeter LPMR-A41, Automatic Polarimeter LPMR-A40, Automatic Polarimeter LPMR-A43, Automatic Polarimeter LPMR-A45, Automatic Polarimeter LPMR-A46, Automatic Polarimeter LPMR-A42, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.