Automatic Polarimeter LPMR-A45

Automatic Polarimeter LPMR-A45

Automatic Polarimeter LPMR-A45 offers an optical rotation measuring fan tin of +90° for accurately capturing both small and large angular rotations. It includes digital optical rotation readings for enhanced sensitivity and reducing calculation errors. The system features electronic signature compliance for secure user authentication and time-stamped approvals. Our automatic polarimeter is equipped with an 8-inch touchscreen display interface for navigating variable parameters.

Request Quote
Measurement Mode Optical rotation, specific rotation, concentration, sugar content
Light Source LED
Working Wavelength 589.3nm / 546mm
Measuring Fan Tin +90°
Measurement Accuracy ±0.003°
Minimum Reading 0.0001°
Repeatability 0.002° (optical rotation)
Test Function Single, multiple, continuous test mode
Temperature Control Range 10℃ to 60℃
Temperature Display 0 to 100℃
Temperature Control Accuracy ± 0.1℃
Light Transmittance 0.05%
Display Mode Touch Screen 10inches
User Management Yes
Automatic Calibration Yes / standard tube
Audit Trail Yes
Electronic Signature Yes
Output Mode USB RS 232, VGA, Ethernet
Real Time Printing of Data Yes, compatible with needle type printer/ thermal sensitive printer
Data Storage 32G
Power Supply 220V ± 22V, 50Hz ± 1Hz
Power Consumption 250 W
Net Weight 28 kg
  • Sugar Content Analysis

  • Minimum Reading Resolution

  • User Calibration Mode

  • High Data Storage 

  • Dynamic Graph Display 

Automatic Polarimeter LPMR-A45 rapidly determines optical rotation and specific rotation. It is ideal across various industries including sugar production, petroleum, food, chemicals, and research industries for analyzing optical activities.

Models of Automatic Polarimeter

Labtron Automatic Polarimeter features built-in Peltier temperature control systems, offering precise readings across various temperatures. They utilize long-life LEDs as their light source, eliminating frequent replacements. Their multiple measurement modes—optical and specific rotation, concentration, and international sugar content give comprehensive analysis. Our Automatic Polarimeter comes with a wide measurement range, coupled with robust data storage and connectivity options.

Automatic Polarimeter LPMR-A40

Automatic Polarimeter LPMR-A40

  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: 259° Z
Automatic polarimeter LPMR-A30

Automatic polarimeter LPMR-A30

  • Measurement mode : Four modes: optical rotation, specific rotation, concentration and international sugar content
  • Calibration mode : Automatic Calibration
  • Measuring Range : ±89.99°, ±259°Z
  • Minimum reading : 0.001°(optical rotation)
Automatic Polarimeter LPMR-A43

Automatic Polarimeter LPMR-A43

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A46
Automatic Polarimeter LPMR-A46
  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A41
Automatic Polarimeter LPMR-A41
  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: 259° Z
Automatic Polarimeter LPMR-A47

Automatic Polarimeter LPMR-A47

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A44

Automatic Polarimeter LPMR-A44

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A31

Automatic Polarimeter LPMR-A31

  • Measurement Mode : Optical rotation, specific rotation, sugar degree, and concentration (Custom)
  • Calibration Mode : Multi-point automatic calibration
  • Measuring Range : ±90° (Optical Rotation) ± 259° Z (Sugar)
  • Minimum Reading : 0.001°

Automatic Polarimeter LPMR-A45 FAQ's
  • Labtron’s automatic polarimeters LPMR-A45 incorporate continuous or kinetic measurement modes that record optical rotation at set time intervals and generate dynamic trend graphs showing rotation versus time. These graphs are displayed in real time and logged for post-run analysis, enabling the study of reaction kinetics such as sugar inversion or enzymatic activity. Users can overlay multiple reaction profiles, set thresholds, and export timestamped data, which enhances method development, reaction optimization, and process control without manual sampling or intervention.

  • Labtron’s automatic polarimeters LPMR-A45 are typically calibrated using both Sucrose/fructose solutions and quartz control plates. ICUMSA standards guide the preparation of sugar solutions across a concentration range, but quartz plates—being stable, solid, and NIST-traceable—are often preferred due to minimized evaporation and preparation errors Calibration routines include zeroing with a blank, measuring the quartz plate at multiple orientations, recording the average value, and verifying it against certified specifications. Calibration checks are usually performed quarterly or after maintenance, with full documentation required. This practice ensures that the instrument meets established performance criteria and produces reliable, traceable results.

  • Errors can arise from temperature changes, wavelength drift, sample path length inaccuracies, bubbles or turbidity, and incorrect sample concentration. To minimize these, polarimeters typically incorporate active Peltier temperature control and require users to input exact tube length into the software. Sample preparation steps like filtration, degassing, and careful filling reduce artifacts from air bubbles or particles. Periodic recalibration compensates for drift from aging filters or light sources, while controlled lab conditions (stable temperature, minimal vibration) prevent environmental interference.

  • Labtron supplies premium automatic polarimeter LPMR-A45. Temperature fluctuations can significantly alter optical rotation values due to the temperature dependency of specific rotation. Automatic polarimeters with Peltier-based temperature control actively maintain the sample at a precise set point—typically reducing drift and enhancing measurement consistency. By stabilizing temperature quickly and quietly, they allow for repeated measurements over extended periods without variation, ensuring more reliable results—even in labs without strict climate control. This stabilization is crucial for pharmaceutical, research, and food analysis applications, where small temperature-dependent shifts can influence decision-making or quality control.

  • Labtron supplies premium automatic polarimeter LPMR-A45. When readings fluctuate, common corrective steps include: first, cleaning the optical surfaces and sample tube to remove residues or fingerprints; second, checking for air bubbles or turbidity in the sample and degassing if necessary; third, verifying that the instrument’s light source and calibration are within specification, replacing or recalibrating as needed Ensure the sample cell length is correctly entered into the system to avoid calculation errors. Environmental factors like ambient temperature swings or vibrations can also affect stability—operating the instrument under consistent lab conditions helps mitigate this. If the issue persists, running a quartz plate check and contacting technical support is advisable.

Post your question?

Our experts are here to help!

Automatic Polarimeter:
Automatic Polarimeter LPMR-A40, Automatic polarimeter LPMR-A30, Automatic Polarimeter LPMR-A43, Automatic Polarimeter LPMR-A46, Automatic Polarimeter LPMR-A41, Automatic Polarimeter LPMR-A47, Automatic Polarimeter LPMR-A44, Automatic Polarimeter LPMR-A31, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.