| Measurement Mode | Optical rotation, specific rotation, concentration, sugar content |
| Light Source | LED |
| Working Wavelength | 589.3nm |
| Measuring Fan Tin | +90° |
| Measurement Accuracy | ±0.004° |
| Minimum Reading | 0.001° |
| Repeatability | 0.002° (optical rotation) |
| Test Function | Single, multiple, continuous test mode |
| Temperature Control Range | 10℃ to 50℃ |
| Temperature Display | 0 to 100℃ |
| Temperature Control Accuracy | ± 0.1℃ |
| Light Transmittance | 0.05% |
| Display Mode | Touch Screen 8inches |
| User Management | Yes |
| Automatic Calibration | Yes |
| Audit Trail | Yes |
| Electronic Signature | Yes |
| Output Mode | USB RS 232, VGA, Ethernet |
| Real Time Printing of Data | Yes, compatible with needle type printer/ thermal sensitive printer |
| Data Storage | 16G |
| Power Supply | 220V ± 22V, 50Hz ± 1Hz |
| Power Consumption | 250 W |
| Net Weight | 28 kg |
Extended LED Lifespan
Peltier-based temperature control
Automatic Calibration System
Electronic Signature Compliance
Real-Time Measurement Visualization
Automatic Polarimeter LPMR-A44 automate the analyzer’s rotation to find the minimum light intensity. It is widely utilized in cosmetics, environmental, forensic laboratories, material sciences and nanotech for analyzing the optical activities
Download catalog for
Automatic Polarimeter LPMR-A44 Catalog
Available Range :
Automatic polarimeter LPMR-A30 : Four modes: optical rotation, specific rotation, concentration and international sugar content Automatic Polarimeter LPMR-A43 : Optical rotation, specific rotation, concentration, sugar content Automatic Polarimeter LPMR-A31 : Optical rotation, specific rotation, sugar degree, and concentration (Custom) Automatic Polarimeter LPMR-A40 : Rotation, specific curl, sugar content, custom formulaLabtron Automatic Polarimeter features built-in Peltier temperature control systems, offering precise readings across various temperatures. They utilize long-life LEDs as their light source, eliminating frequent replacements. Their multiple measurement modes—optical and specific rotation, concentration, and international sugar content give comprehensive analysis. Our Automatic Polarimeter comes with a wide measurement range, coupled with robust data storage and connectivity options.








Labtron supplies advanced automatic polarimeter LPMR-A44 support remote diagnostics via Ethernet or internet connection, enabling service engineers to access the instrument for troubleshooting, calibration verification, and firmware updates. This reduces downtime and eliminates the need for onsite visits, particularly valuable in regulated or GPS-limited environments. On-device self-tests and LED diagnostics help catch faults early, and real-time remote support ensures continuous operation and compliance with minimal maintenance effort.
Labtron supplies premium automatic polarimeter LPMR-A44. Calibration frequency depends on usage intensity and regulatory requirements-typically quarterly or after significant maintenance, relocation, or light source replacement. Quartz plates traceable to NIST are often used for multi-point calibration, offering a stable and reliable standard compared to sugar solutions. As an alternative, known-concentration sucrose or fructose solutions may be used, ensuring linear response and correlation coefficient above 0.99. Calibration data, date, results, and acceptance should be recorded and maintained in logs.
Labtron supplies premium automatic polarimeter LPMR-A44. Key sources of error include temperature fluctuations, wavelength deviations, cell path length inaccuracies, sample clarity issues, and concentration variability. Temperature control via Peltier systems addresses thermal drift, while built-in wavelength filters ensure monochromatic light. Users input actual cell length to correct calculations, and filtered or clear samples prevent scattering errors. Regular sample and cell cleaning removes air bubbles or debris, and frequent calibration maintains overall accuracy.
Automatic polarimeters LPMR-A44 are typically calibrated using both Sucrose/fructose solutions and quartz control plates. ICUMSA standards guide the preparation of sugar solutions across a concentration range, but quartz plates—being stable, solid, and NIST-traceable—are often preferred due to minimized evaporation and preparation errors. Calibration routines include zeroing with a blank, measuring the quartz plate at multiple orientations, recording the average value, and verifying it against certified specifications. Calibration checks are usually performed quarterly or after maintenance, with full documentation required. This practice ensures that the instrument meets established performance criteria and produces reliable, traceable results.
Labtron supplies advanced automatic polarimeter LPMR-A44. Errors can arise from temperature changes, wavelength drift, sample path length inaccuracies, bubbles or turbidity, and incorrect sample concentration. To minimize these, polarimeters typically incorporate active Peltier temperature control and require users to input exact tube length into the software. Sample preparation steps like filtration, degassing, and careful filling reduce artifacts from air bubbles or particles. Periodic recalibration compensates for drift from aging filters or light sources, while controlled lab conditions (stable temperature, minimal vibration) prevent environmental interference.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom