Automatic Polarimeter LPMR-A46

Automatic Polarimeter LPMR-A46

Automatic Polarimeter LPMR-A46 offers a minimum reading of 0.0001°, allowing the device to detect and display extremely small variations in rotation. It has multiple measurement modes for quick switching between analysis types. The polarimeter features an extended LED lifespan, ensuring ultra-long operational time and lower maintenance. Our automatic polarimeter provides a dynamic graph display, providing real-time visualization of changes throughout the measurement process.

Request Quote
Measurement Mode Optical rotation, specific rotation, concentration, sugar content
Light Source LED
Working Wavelength 589.3nm / 546mm
Measuring Fan Tin +90°
Measurement Accuracy ±0.002°
Minimum Reading 0.0001°
Repeatability 0.002° (optical rotation)
Test Function Single, multiple, continuous test mode
Temperature Control Range 10℃ to 60℃
Temperature Display 0 to 100℃
Temperature Control Accuracy ± 0.1℃
Light Transmittance 0.05%
Display Mode Touch Screen 10inches
User Management Yes
Automatic Calibration Yes / standard tube
Audit Trail Yes
Electronic Signature Yes
Output Mode USB RS 232, VGA, Ethernet
Real Time Printing of Data Yes, compatible with needle type printer/ thermal sensitive printer
Data Storage 64G
Power Supply 220V ± 22V, 50Hz ± 1Hz
Power Consumption 250 W
Net Weight 28 kg
  • Peltier-based temperature control

  • Minimum Reading Resolution

  • User Calibration Mode

  • Specific Rotation Calculation

  • Multiple Measurement Modes

Automatic Polarimeter LPMR-A46 automatically measures the angle of rotation of polarized light. It plays a key role in pharmaceutical, food, beverage, research and chemical manufacturing for purity analysis and concentration determination.

Models of Automatic Polarimeter

Labtron Automatic Polarimeter features built-in Peltier temperature control systems, offering precise readings across various temperatures. They utilize long-life LEDs as their light source, eliminating frequent replacements. Their multiple measurement modes—optical and specific rotation, concentration, and international sugar content give comprehensive analysis. Our Automatic Polarimeter comes with a wide measurement range, coupled with robust data storage and connectivity options.

Automatic Polarimeter LPMR-A40

Automatic Polarimeter LPMR-A40

  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: 259° Z
Automatic Polarimeter LPMR-A41

Automatic Polarimeter LPMR-A41

  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: 259° Z
Automatic polarimeter LPMR-A30

Automatic polarimeter LPMR-A30

  • Measurement mode : Four modes: optical rotation, specific rotation, concentration and international sugar content
  • Calibration mode : Automatic Calibration
  • Measuring Range : ±89.99°, ±259°Z
  • Minimum reading : 0.001°(optical rotation)
Automatic Polarimeter LPMR-A47
Automatic Polarimeter LPMR-A47
  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A31
Automatic Polarimeter LPMR-A31
  • Measurement Mode : Optical rotation, specific rotation, sugar degree, and concentration (Custom)
  • Calibration Mode : Multi-point automatic calibration
  • Measuring Range : ±90° (Optical Rotation) ± 259° Z (Sugar)
  • Minimum Reading : 0.001°
Automatic Polarimeter LPMR-A42

Automatic Polarimeter LPMR-A42

  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: ±259°Z
Automatic Polarimeter LPMR-A45

Automatic Polarimeter LPMR-A45

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A43

Automatic Polarimeter LPMR-A43

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm
  • Measuring Fan Tin : +90°

Automatic Polarimeter LPMR-A46 FAQ's
  • Labtron supplies premium automatic polarimeter LPMR-A46. Calibration of polarimeters can be accomplished using NIST-traceable quartz plates or standard sugar solutions (sucrose/fructose) prepared at known concentrations. Quartz plates are preferred for their long-term stability, while sugar solutions offer practical verification of linear response over a range of values (turn0search2, turn0search12). Instruments are often calibrated quarterly or after key events such as lamp replacement or relocation. Calibration routines include zeroing with blank solvent, measuring standards, and comparing results against specifications. Complete records—time, operator, instrument settings, and measured values—should be logged for traceability and audit compliance, especially in regulated environments.

  • Labtron supplies premium automatic polarimeter LPMR-A46. When readings fluctuate, common corrective steps include: first, cleaning the optical surfaces and sample tube to remove residues or fingerprints; second, checking for air bubbles or turbidity in the sample and degassing if necessary; third, verifying that the instrument’s light source and calibration are within specification, replacing or recalibrating as needed Ensure the sample cell length is correctly entered into the system to avoid calculation errors. Environmental factors like ambient temperature swings or vibrations can also affect stability—operating the instrument under consistent lab conditions helps mitigate this. If the issue persists, running a quartz plate check and contacting technical support is advisable.

  • Labtron supplies automatic polarimeter LPMR-A46.While polarimeters are typically used for clear liquid samples, some models offer solid sample holders or flow-cell adapters that enable analysis of suspensions or semi-solids. For turbid solutions, the device may require sample pre-treatment such as filtration or centrifugation to remove particulates that could skew readings. This allows versatile applications beyond simple liquid assays, though sample clarity remains essential for accurate measurements.

  • Labtron supplies automatic polarimeter LPMR-A46.Modern models employ Peltier elements to maintain sample temperature within tight tolerances, often between 10–60?°C, minimizing drift caused by thermal variation. Temperature accuracy with resolution. This active control compensates for ambient fluctuations in non-air-conditioned environments. Some systems also support pre-heating or cooling before measurement, improving result stability and reducing waiting time.

  • Labtron supplies premium automatic polarimeter LPMR-A46. Key sources of error include temperature fluctuations, wavelength deviations, cell path length inaccuracies, sample clarity issues, and concentration variability. Temperature control via Peltier systems addresses thermal drift, while built-in wavelength filters ensure monochromatic light. Users input actual cell length to correct calculations, and filtered or clear samples prevent scattering errors. Regular sample and cell cleaning removes air bubbles or debris, and frequent calibration maintains overall accuracy.

Post your question?

Our experts are here to help!

Automatic Polarimeter:
Automatic Polarimeter LPMR-A40, Automatic Polarimeter LPMR-A41, Automatic polarimeter LPMR-A30, Automatic Polarimeter LPMR-A47, Automatic Polarimeter LPMR-A31, Automatic Polarimeter LPMR-A42, Automatic Polarimeter LPMR-A45, Automatic Polarimeter LPMR-A43, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.