Request A Quote
Automatic Polarimeter LPMR-A43

Automatic Polarimeter LPMR-A43

Automatic Polarimeter LPMR-A43 features a working wavelength of 589.3nm, ensuring standardized measurement of optical rotation. The built-in Peltier temperature control maintains stability for consistent results. It has an extended LED lifespan, ensuring ultra-long operational time and lower maintenance. Our automatic polarimeter offers high-capacity data storage, enabling efficient data management and easy integration with laboratory systems.

Request Quote
Measurement Mode Optical rotation, specific rotation, concentration, sugar content
Light Source LED
Working Wavelength 589.3nm
Measuring Fan Tin +90°
Measurement Accuracy ±0.001°
Minimum Reading 0.001°
Repeatability 0.002° (optical rotation)
Test Function Single, multiple, continuous test mode
Temperature Control Range 10℃ to 50℃
Temperature Display 0 to 100℃
Temperature Control Accuracy ± 0.1℃
Light Transmittance 0.1%
Display Mode Touch Screen 7 inches
User Management Yes
Automatic Calibration Yes
Output Mode USB RS 232
Real Time Printing of Data Yes, compatible with needle type printer/ thermal sensitive printer
Data Storage 1000M
Power Supply 220V ± 22V, 50Hz ± 1Hz
Power Consumption 250 W
Net Weight 28 kg
  • Fully Automatic Measurement

  • Digital Optical Rotation Readings

  • Specific Rotation Calculation

  • Multiple Measurement Modes

  • Minimum Reading Resolution

Automatic Polarimeter LPMR-A43 automatically measures the angle of rotation of polarized light. It plays a key role in pharmaceutical, food, beverage, research and chemical manufacturing for purity analysis and concentration determination.

Models of Automatic Polarimeter

Labtron Automatic Polarimeter features built-in Peltier temperature control systems, offering precise readings across various temperatures. They utilize long-life LEDs as their light source, eliminating frequent replacements. Their multiple measurement modes—optical and specific rotation, concentration, and international sugar content give comprehensive analysis. Our Automatic Polarimeter comes with a wide measurement range, coupled with robust data storage and connectivity options.

Automatic Polarimeter LPMR-A46

Automatic Polarimeter LPMR-A46

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A40

Automatic Polarimeter LPMR-A40

  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: 259° Z
Automatic Polarimeter LPMR-A45

Automatic Polarimeter LPMR-A45

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A42
Automatic Polarimeter LPMR-A42
  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: ±259°Z
Automatic polarimeter LPMR-A30
Automatic polarimeter LPMR-A30
  • Measurement mode : Four modes: optical rotation, specific rotation, concentration and international sugar content
  • Calibration mode : Automatic Calibration
  • Measuring Range : ±89.99°, ±259°Z
  • Minimum reading : 0.001°(optical rotation)
Automatic Polarimeter LPMR-A47

Automatic Polarimeter LPMR-A47

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A31

Automatic Polarimeter LPMR-A31

  • Measurement Mode : Optical rotation, specific rotation, sugar degree, and concentration (Custom)
  • Calibration Mode : Multi-point automatic calibration
  • Measuring Range : ±90° (Optical Rotation) ± 259° Z (Sugar)
  • Minimum Reading : 0.001°
Automatic Polarimeter LPMR-A41

Automatic Polarimeter LPMR-A41

  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: 259° Z

Automatic Polarimeter LPMR-A43 FAQ's
  • Labtron’s automatic polarimeter LPMR-A43 perform multi-point calibration using standards like quartz plates or sugar solutions. Calibration may be scheduled daily, weekly, or monthly based on usage and regulatory protocols. The device often includes dual calibration tubes and built-in routines to verify accuracy across the measurement range. Calibration records are typically stored digitally and can be exported for validation or audit purposes. This ensures that measurement results remain consistent and traceable to recognized standards.

  • Labtron supplies automatic polarimeter LPMR-A43.Modern models employ Peltier elements to maintain sample temperature within tight tolerances, often between 10–60?°C, minimizing drift caused by thermal variation. Temperature accuracy with resolution. This active control compensates for ambient fluctuations in non-air-conditioned environments. Some systems also support pre-heating or cooling before measurement, improving result stability and reducing waiting time.

  • Labtron automatic polarimeters LPMR-A43 offer continuous measurement or kinetic modes, which record optical rotation at defined time intervals and build dynamic trend graphs. Devices may display these trends in real-time on screen and allow export of timestamped data for post-run analysis. These tools are useful for monitoring reaction progress, such as sugar inversion or enzymatic activity, without manual intervention. The continuous mode enables overlay of multiple runs to compare reaction kinetics under different conditions.

  • Yes, automatic polarimeter LPMR-A43 can determine enantiomeric excess by comparing the observed optical rotation of a sample to the known rotation value for a pure enantiomer. They calculate ee% using built-in algorithms, providing insight into chiral purity directly from measurement data. This feature is valuable in pharmaceutical and chemical research where enantiomer ratios are critical for efficacy and safety. The automatic comparison reduces manual calculations and potential errors, streamlining enantioselective analysis.

  • Labtron supplies automatic polarimeter LPMR-A43.While polarimeters are typically used for clear liquid samples, some models offer solid sample holders or flow-cell adapters that enable analysis of suspensions or semi-solids. For turbid solutions, the device may require sample pre-treatment such as filtration or centrifugation to remove particulates that could skew readings. This allows versatile applications beyond simple liquid assays, though sample clarity remains essential for accurate measurements.

Post your question?

Our experts are here to help!

Automatic Polarimeter:
Automatic Polarimeter LPMR-A46, Automatic Polarimeter LPMR-A40, Automatic Polarimeter LPMR-A45, Automatic Polarimeter LPMR-A42, Automatic polarimeter LPMR-A30, Automatic Polarimeter LPMR-A47, Automatic Polarimeter LPMR-A31, Automatic Polarimeter LPMR-A41, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.