Automatic Polarimeter LPMR-A41 features a temperature control system that maintains stability between 10°C to 60°C with an accuracy of ±0.03°C. Its optional minimum reading of 0.0001° enables high-precision optical measurements. The 8-inch TFT touchscreen provides a user-friendly interface for seamless operation. Equipped with a built-in HP printer, it allows direct documentation of results. Our polarimeter is ideal for pharmaceutical, research, and food industry applications requiring reliable substance analysis.
Measurement Mode | Rotation, specific curl, sugar content, custom formula |
Light Source | LED cold light + interference filter |
Working Wavelength | 589.3 nm |
Measuring Range | Optical rotation: ±90°, Sugar: 259° Z |
Minimum Reading | 0.001° (0.0001° Optional) |
Accuracy | ±0.002° |
Repeatability | 0.002° (Optional rotation) |
Temperature Control | Peltier system, 10°C to 56°C |
Temperature Accuracy | ±1.0°C |
Temperature Control Accuracy | ±0.03°C |
Display | 8-inch TFT touchscreen |
Standard Test Tubes | 100mm & 200mm (optional temp control) |
Data Storage | 64GB internal memory |
Compliance | 21 CFR Part 11, audit trail, e-signature |
Connectivity | USB, RS232, VGA, Ethernet |
Export Formats | PDF, Excel |
Power Supply | 220V ±22V, 50Hz ±1Hz, 250W |
Weight | 30 kg |
Dimensions | 820 × 475 × 465 mm |
Automatic calibration system
64GB data storage capacity
WiFi and USB printing compatibility
Our Automatic Polarimeter LPMR-A41 ensures precise analysis of sugars, pharmaceuticals, and chemicals. It evaluates sugar concentration, drug purity, and chemical composition. Ideal for quality control, formulation studies, and material verification.
Accessory Name | Quantity |
Polarimeter Temperature Control Tube 100mm (Stainless Steel) | 1 |
Polarimeter Temperature Control Tube 100mm (Anti-Corrosion) | 1 |
Polarimeter Temperature Control Tube 200mm (Stainless Steel) | 1 |
Polarimeter Temperature Control Tube 200mm (Anti-Corrosion) | 1 |
Download catalog for
Automatic Polarimeter LPMR-A41 Catalog
Available Range :
Automatic polarimeter LPMR-A30 : Four modes: optical rotation, specific rotation, concentration and international sugar content Automatic Polarimeter LPMR-A31 : Optical rotation, specific rotation, sugar degree, and concentration (Custom) Automatic Polarimeter LPMR-A40 : Rotation, specific curl, sugar content, custom formulaLabtron Automatic Polarimeter features built-in Peltier temperature control systems, offering precise readings across various temperatures. They utilize long-life LEDs as their light source, eliminating frequent replacements. Their multiple measurement modes—optical and specific rotation, concentration, and international sugar content give comprehensive analysis. Our Automatic Polarimeter comes with a wide measurement range, coupled with robust data storage and connectivity options.
Our Automatic Polarimeter offers rotation, specific curl, sugar content, and a custom formula mode. These modes allow users to measure various sample properties in research, quality control, and industrial applications. The flexibility makes it ideal for laboratories working with diverse substances. Users can easily select the appropriate mode via the intuitive touchscreen interface.
Labtron’s Automatic Polarimeter includes a 64GB internal memory for secure data storage. Users can export results in multiple formats, including PDF and Excel, for further analysis. It also supports connectivity via USB, RS232, VGA, and Ethernet for easy data transfer. This ensures efficient record-keeping and compliance with regulatory standards.
The Automatic Polarimeter complies with 21 CFR Part 11, featuring audit trails, electronic signatures, and multi-level user management. These features help laboratories meet strict industry regulations, particularly in pharmaceuticals and research. Compliance ensures secure data handling and traceability of all measurement records.
The Automatic Polarimeter includes a built-in HP printer for direct result documentation. This allows users to print measurement data without external devices, streamlining workflow efficiency. It also supports WiFi printing, offering flexibility in laboratory setups. Printed records ensure easy compliance with documentation requirements.
Our Automatic Polarimeter features an 8-inch TFT touchscreen for seamless operation and quick parameter adjustments. The built-in data storage and multiple connectivity options allow efficient data management. With automated calibration and a user-friendly interface, it minimizes manual input, reducing errors. These features streamline workflow in high-throughput laboratories.
Labtron’s Automatic Polarimeter offers multiple connectivity options, including USB, RS232, VGA, and Ethernet. This allows seamless data transfer to external devices for analysis and reporting. It also supports direct printing, eliminating the need for manual record-keeping. These features enhance laboratory efficiency and data accessibility.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608