Request A Quote
Automatic Polarimeter LPMR-A47

Automatic Polarimeter LPMR-A47

Automatic Polarimeter LPMR-A47 features a temperature control accuracy of ± 0.1℃, ensuring that sample temperature remains highly stable during measurements. It has a high-temperature resolution, detecting subtle temperature variations. The polarimeter provides high-capacity data storage for efficient data management and easy integration with laboratory systems. Our automatic polarimeter offers an extended LED lifespan, ensuring ultra-long operational time and lower maintenance.

Request Quote
Measurement Mode Optical rotation, specific rotation, concentration, sugar content
Light Source LED
Working Wavelength 589.3nm / 546mm
Measuring Fan Tin +90°
Measurement Accuracy ±0.002°
Minimum Reading 0.0001°
Repeatability 0.002° (optical rotation)
Test Function Single, multiple, continuous test mode
Temperature Control Range 10℃ to 60℃
Temperature Display 0 to 100℃
Temperature Control Accuracy ± 0.1℃
Light Transmittance 0.01%
Display Mode Touch Screen 10.4 inches
User Management Yes
Automatic Calibration Yes / standard tube
Audit Trail Yes
Electronic Signature Yes
Output Mode USB RS 232, VGA, Ethernet
Real Time Printing of Data Yes, compatible with needle type printer/ thermal sensitive printer
Data Storage 128G
Power Supply 220V ± 22V, 50Hz ± 1Hz
Power Consumption 250 W
Net Weight 28 kg
  • Specific Rotation Calculation

  • Sugar Content Analysis

  • Minimum Reading Resolution

  • Digital Optical Rotation Readings

  • Electronic Signature Compliance

Automatic Polarimeter LPMR-A47 automates the analyzer’s rotation to find the minimum light intensity. It is widely utilized in cosmetics, environmental, forensic laboratories, material sciences, and nanotech for analyzing optical activities.

Models of Automatic Polarimeter

Labtron Automatic Polarimeter features built-in Peltier temperature control systems, offering precise readings across various temperatures. They utilize long-life LEDs as their light source, eliminating frequent replacements. Their multiple measurement modes—optical and specific rotation, concentration, and international sugar content give comprehensive analysis. Our Automatic Polarimeter comes with a wide measurement range, coupled with robust data storage and connectivity options.

Automatic Polarimeter LPMR-A31

Automatic Polarimeter LPMR-A31

  • Measurement Mode : Optical rotation, specific rotation, sugar degree, and concentration (Custom)
  • Calibration Mode : Multi-point automatic calibration
  • Measuring Range : ±90° (Optical Rotation) ± 259° Z (Sugar)
  • Minimum Reading : 0.001°
Automatic Polarimeter LPMR-A44

Automatic Polarimeter LPMR-A44

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm
  • Measuring Fan Tin : +90°
Automatic polarimeter LPMR-A30

Automatic polarimeter LPMR-A30

  • Measurement mode : Four modes: optical rotation, specific rotation, concentration and international sugar content
  • Calibration mode : Automatic Calibration
  • Measuring Range : ±89.99°, ±259°Z
  • Minimum reading : 0.001°(optical rotation)
Automatic Polarimeter LPMR-A45
Automatic Polarimeter LPMR-A45
  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A41
Automatic Polarimeter LPMR-A41
  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: 259° Z
Automatic Polarimeter LPMR-A43

Automatic Polarimeter LPMR-A43

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A46

Automatic Polarimeter LPMR-A46

  • Measurement Mode : Optical rotation, specific rotation, concentration, sugar content
  • Light Source : LED
  • Working Wavelength : 589.3nm / 546mm
  • Measuring Fan Tin : +90°
Automatic Polarimeter LPMR-A42

Automatic Polarimeter LPMR-A42

  • Measurement Mode : Rotation, specific curl, sugar content, custom formula
  • Light Source : LED cold light + interference filter
  • Working Wavelength : 589.3 nm
  • Measuring Range : Optical rotation: ±90°, Sugar: ±259°Z

Automatic Polarimeter LPMR-A47 FAQ's
  • Labtron supplies automatic polarimeter LPMR-A47.Modern models employ Peltier elements to maintain sample temperature within tight tolerances, often between 10–60?°C, minimizing drift caused by thermal variation. Temperature accuracy with resolution. This active control compensates for ambient fluctuations in non-air-conditioned environments. Some systems also support pre-heating or cooling before measurement, improving result stability and reducing waiting time.

  • Labtron supplies premium automatic polarimeter LPMR-A47. Calibration frequency depends on usage intensity and regulatory requirements-typically quarterly or after significant maintenance, relocation, or light source replacement. Quartz plates traceable to NIST are often used for multi-point calibration, offering a stable and reliable standard compared to sugar solutions. As an alternative, known-concentration sucrose or fructose solutions may be used, ensuring linear response and correlation coefficient above 0.99. Calibration data, date, results, and acceptance should be recorded and maintained in logs.

  • Errors can arise from temperature changes, wavelength drift, sample path length inaccuracies, bubbles or turbidity, and incorrect sample concentration. To minimize these, polarimeters typically incorporate active Peltier temperature control and require users to input exact tube length into the software. Sample preparation steps like filtration, degassing, and careful filling reduce artifacts from air bubbles or particles. Periodic recalibration compensates for drift from aging filters or light sources, while controlled lab conditions (stable temperature, minimal vibration) prevent environmental interference.

  • Labtron supplies premium automatic polarimeter LPMR-A47. Temperature fluctuations can significantly alter optical rotation values due to the temperature dependency of specific rotation. Automatic polarimeters with Peltier-based temperature control actively maintain the sample at a precise set point—typically reducing drift and enhancing measurement consistency. By stabilizing temperature quickly and quietly, they allow for repeated measurements over extended periods without variation, ensuring more reliable results—even in labs without strict climate control. This stabilization is crucial for pharmaceutical, research, and food analysis applications, where small temperature-dependent shifts can influence decision-making or quality control.

  • Labtron supplies automatic polarimeter LPMR-A47.While polarimeters are typically used for clear liquid samples, some models offer solid sample holders or flow-cell adapters that enable analysis of suspensions or semi-solids. For turbid solutions, the device may require sample pre-treatment such as filtration or centrifugation to remove particulates that could skew readings. This allows versatile applications beyond simple liquid assays, though sample clarity remains essential for accurate measurements.

Post your question?

Our experts are here to help!

Automatic Polarimeter:
Automatic Polarimeter LPMR-A31, Automatic Polarimeter LPMR-A44, Automatic polarimeter LPMR-A30, Automatic Polarimeter LPMR-A45, Automatic Polarimeter LPMR-A41, Automatic Polarimeter LPMR-A43, Automatic Polarimeter LPMR-A46, Automatic Polarimeter LPMR-A42, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608