Request A Quote
Distillation Tester Front Type LDT-A14

Distillation Tester Front Type LDT-A14

Distillation Tester Front Type LDT-A14 features a distillation flask of 125 ml to provide accurate measurement, stable performance and efficient testing of petroleum product boiling ranges. It is equipped with a temperature control system for stable heating. The tester includes a clear glass cylinder allowing direct monitoring of distillation progress. Our distillation tester offers precise boiling range analysis, user-friendly operation, reliable safety features and compliance with ASTM D86. 

Request Quote
Distillation flask 125 ml
Ambient temperature Room temperature to 35°C
Relative humidity ≤ 85 %
Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Division value 1℃
Receiving cylinder 100 ml
Scale division 1 ml
Flask Support Board φ32 mm, φ38 mm, φ50 mm
Heating power system 1000 W
Power supply AC 220 V ± 10 %, 50 Hz
Dimension 620 × 510 × 620 mm
  • Compact Desktop Structure
  • Flexible Convenient Operation
  • Safe Heating Furnace
  • Adjustable Heating Power
  • Easy Lifting Device

Distillation Tester Front Type LDT-A14 is a device used to determine the boiling range of petroleum products. It is used to determine distillation characteristics of natural gasoline, vehicle gasoline, aviation gasoline, jet fuels, naphtha, diesel oil and similar petroleum products.

Accessories Name 

Quantity 

Distillation Flask (125 ml)

1 pc

Glass Container (100mm × 240mm)

1 pc

Thermometer -2 °C to 300 ℃ and -2 °C to 400 ℃

1 pc

Silica Gel Stopper 

2 pc

Silica Carbide Board

2 pc

Graduated Flask (100ml)

1 pc

Iron Weight 

1 pc

Stopping Ring for the thermometer (1#)

4 pc

6 A fuse (Φ5 × 20)

2 pc

Observation Window Glass

1 pc

Condensate Pipe Outlet Cover

1 pc

Models of Distillation Tester

Labtron Distillation Tester determine boiling point characteristics for analyzing purity and composition of substance. Their high-quality glass components ensure visibility while withstanding rigors of use. They utilize energy-efficient heating elements to minimize power consumption during lengthy processing. Their innovative design minimizes cross-contamination risks between different fractions, ensuring purity. Our Distillation Tester is suitable for oil and gas industry to assess crude oil fractions and in pharmaceuticals to check solvent purity.

Distillation Tester LDT-A17

Distillation Tester LDT-A17

  • Distillation Flask : 125 ml
  • Graduated Flasks : 100 ml
  • Ambient Temperature : ≤ 30 °C
  • Relative Humidity : ≤ 85 %
Atmospheric Distillation Tester LDT-A22

Atmospheric Distillation Tester LDT-A22

  • Condenser capacity : 8.3L
  • Distillation range : Room temperature to 400 ℃
  • Condensation method : Compressor refrigeration
  • Distillation heating power : 0 to 1200 W (continuous adjustable)
Distillation Tester Dual Units LDT-A15

Distillation Tester Dual Units LDT-A15

  • Graduated flasks : 100 ml
  • Scale division of graduated flask : 1ml
  • Distillation flask : 125 ml
  • Ambient temperature : ≤ 35 °C
Vacuum Distillation Tester LDT-A18
Vacuum Distillation Tester LDT-A18
  • Evaporation tube specifications : 200 Φ mm
  • Evaporation tube heat transfer area : 0.4 m2
  • Built-in cooling area : 0.5 m2
  • Constant pressure feeding bottle : 3 L
Automatic Distillation Apparatus LDT-A21
Automatic Distillation Apparatus LDT-A21
  • Heating Power : 2 KW
  • Refrigeration Power : 0.5 KW
  • Standard : ASTM D86
  • Display : 10.4-inch large color touchscreen
Benzene Distillation Tester (Low Temperature) LDT-A11

Benzene Distillation Tester (Low Temperature) LDT-A11

  • Ambient temperature : -10°C to 35°C
  • Relative humidity : ≤ 85 %
  • Thermometer : Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
  • Scale division : 0.1 ℃
Atmospheric Distillation Tester LDT-A20

Atmospheric Distillation Tester LDT-A20

  • Temperature Range : AT to 400℃
  • Left Bath Temperature Range : 0 to 60℃, Accuracy: ±0.5℃
  • Right Bath Temperature Range : 0 to 60℃, Accuracy: ±0.5℃
  • Receiving Chamber Temperature Range : 0℃ to AT (Auto control)
Vacuum Distillation Tester LDT-A13

Vacuum Distillation Tester LDT-A13

  • Ambient temperature : 5 °C to 35 ℃
  • Relative humidity : ≤ 85 %
  • Cubage of buffer vessel : 1000 ml
  • Max. Residual pressure : ≤ 2 mm Hg

Distillation Tester Front Type LDT-A14 FAQ's
  • Our Distillation Tester Front Type LDT-A14 plays a vital role in managing condenser temperature, which is essential for condensing vaporized components into measurable liquid fractions. The condenser temperature is typically maintained at 0–4°C using an external chiller or cooling bath to ensure efficient vapor condensation. If the temperature is too high, light volatiles may escape, leading to sample loss and inaccurate readings. Maintaining a stable, low condenser temperature is crucial for testing light-end hydrocarbons and achieving high analytical precision.

  • Labtron Distillation Tester Front Type LDT-A14 is designed to safely handle heavier petroleum samples such as diesel and lubricants, which may leave residues or contain high-boiling fractions. It uses a high-temperature-resistant flask and precise heating control to prevent overheating and thermal degradation. As recommended by ASTM D86, tests are typically stopped at the 95% recovery point to preserve equipment and avoid sample degradation. Prompt cleaning of the flask after each test ensures accuracy and longevity of the system.

  • Labtron Distillation Tester Front Type LDT-A14 uses a 1,000 W adjustable electric furnace to provide uniform, stable heat distribution across the distillation flask. Its design reduces thermal lag and overshooting, ensuring a controlled and predictable temperature ramp. This prevents sudden boiling (bumping) and protects delicate or volatile samples from overheating. The integrated heating system supports precision, efficiency, and a broad range of applications, making it highly reliable for ASTM D86 testing.

  • Our Distillation Tester Front Type LDT-A14 is built with standardized fittings and position guides to prevent misplacement of the thermometer bulb, a common source of temperature error. When the bulb is inserted too high or immersed in the liquid, readings can be inaccurate. The unit ensures the bulb is positioned exactly at the vapor exit point, with secure clamping mechanisms to hold it steady throughout the test. This design ensures reproducible and accurate boiling point measurements.

  • Labtron’s Distillation Tester Front Type LDT-A14 is engineered for safe operation with volatile and hazardous petroleum samples. It should be used in a fume hood with proper ventilation and away from ignition sources. The tester works with sealed or explosion-proof power setups, and its cooling system must be active to control vapor release. Operators must wear appropriate PPE, follow guidelines, and dispose of waste responsibly. These practices ensure both user safety and environmental compliance.

Post your question?

Our experts are here to help!

Distillation Tester:
Distillation Tester LDT-A17, Atmospheric Distillation Tester LDT-A22, Distillation Tester Dual Units LDT-A15, Vacuum Distillation Tester LDT-A18, Automatic Distillation Apparatus LDT-A21, Benzene Distillation Tester (Low Temperature) LDT-A11, Atmospheric Distillation Tester LDT-A20, Vacuum Distillation Tester LDT-A13, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.