Request A Quote
Distillation Tester LDT-A16

Distillation Tester LDT-A16

Distillation Tester LDT-A16 features a 125 ml distillation flask and supports operation in ambient temperatures up to 35°C. It features a condenser pipe that reaches as low as 0°C. It uses a compressor-based refrigeration device for efficiency. It is equipped with immersion rod-type thermometers for accurate measurements.  Our distillation tester is a double-unit distillation tester designed for low-temperature conditions.

Request Quote
Distillation Flask 125 ml
Graduated Flasks 100 ml
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Temperature Controlling Accuracy ± 0.5 °C
Thermometer (-2) °C to 300 ℃ and (-2) °C to 400 ℃
Division Value 1°C
Scale Division 1 ml
Heating Power System 1000 W × 2
Total Power Consumption ≤ 5000 W
Power Supply AC 220 V ± 10 %, 50 Hz
Inner Diameter of Electric Furnace φ32 mm, φ38 mm
Outer Diameter of Electric Furnace φ50 mm
Dimension 830 x 610 x 870 mm
  • LED display 
  • Heating Power System
  • Precise temperature control system
  • Sturdy and compact design

Our Distillation Tester LDT-A16 is used for the distillation analysis of petroleum products under barometric pressure conditions. It ensures precise boiling point determination of fuels, solvents, and other petroleum-based liquids.

Distillation Tester LDT-A16 | Distillation Flask: 125 ml | Relative Humidity: ≤ 85 %
Distillation Tester LDT-A16 | LED display | Heating Power System

Models of Distillation Tester

Labtron Distillation Tester determine boiling point characteristics for analyzing purity and composition of substance. Their high-quality glass components ensure visibility while withstanding rigors of use. They utilize energy-efficient heating elements to minimize power consumption during lengthy processing. Their innovative design minimizes cross-contamination risks between different fractions, ensuring purity. Our Distillation Tester is suitable for oil and gas industry to assess crude oil fractions and in pharmaceuticals to check solvent purity.

Distillation Tester Front Type LDT-A14

Distillation Tester Front Type LDT-A14

  • Distillation flask : 125 ml
  • Ambient temperature : Room temperature to 35°C
  • Relative humidity : ≤ 85 %
  • Thermometer : (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Atmospheric Distillation Tester LDT-A22

Atmospheric Distillation Tester LDT-A22

  • Condenser capacity : 5L
  • Distillation range : Room temperature to 400 ℃
  • Condensation method : Compressor refrigeration
  • Distillation heating power : 0 to 1200 W (continuous adjustable)
Atmospheric Distillation Tester LDT-A20

Atmospheric Distillation Tester LDT-A20

  • Temperature Range : AT to 400℃
  • Left Bath Temperature Range : 0 to 60℃, Accuracy: ±0.5℃
  • Right Bath Temperature Range : 0 to 60℃, Accuracy: ±0.5℃
  • Receiving Chamber Temperature Range : 0℃ to AT (Auto control)
Distillation Tester LDT-A10
Distillation Tester LDT-A10
  • Graduated flasks : 10 ml and 100 ml
  • Scale division of graduated flask : 10 ml is 0.1 ml and 100 ml is 1 ml
  • Ambient temperature : (-10) °C ~ 35 °C
  • Relative humidity : ≤ 85 %
Automatic Distillation Apparatus LDT-A21
Automatic Distillation Apparatus LDT-A21
  • Heating Power : 2 KW
  • Refrigeration Power : 0.5 KW
  • Standard : ASTM D86
  • Display : 10.4-inch large color touchscreen
Automated Atmospheric Distillation Tester LDT-A19

Automated Atmospheric Distillation Tester LDT-A19

  • Test Range : 0 to 400 °C
  • Accuracy : ±0.1 °C
  • Receiving Chamber : 0 to 60 °C (0 °C achievable when AT < 15 °C)
  • Condenser Bath : Peltier cooling
Benzene Distillation Tester (Low Temperature) LDT-A11

Benzene Distillation Tester (Low Temperature) LDT-A11

  • Ambient temperature : -10°C to 35°C
  • Relative humidity : ≤ 85 %
  • Thermometer : Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
  • Scale division : 0.1 ℃
Distillation Tester LDT-A17

Distillation Tester LDT-A17

  • Distillation Flask : 125 ml
  • Graduated Flasks : 100 ml
  • Ambient Temperature : ≤ 30 °C
  • Relative Humidity : ≤ 85 %

Distillation Tester LDT-A16 FAQ's
  • The Distillation Tester LDT-A16 is designed to analyze a wide range of petroleum products, such as gasoline, diesel, jet fuels, naphtha, and light crude oil fractions. We ensure the unit complies with ASTM D86 standards, making it ideal for precise distillation range testing. However, it is not recommended for samples with high viscosity or those requiring vacuum distillation. Our equipment performs best with volatile or moderately viscous samples that fall within ambient-pressure testing criteria.

  • Labtron Distillation Tester LDT-A16 typically completes a standard ASTM D86 test within 45 minutes to 1 hour, depending on the complexity of the sample. The dual-unit design enables simultaneous testing, which significantly enhances productivity in busy labs. Our advanced heating and cooling systems help maintain consistent cycle times while ensuring accuracy. Minimal additional time is required for setup and pre-heating.

  • The Distillation Tester LDT-A16 is considered fixed bench-top laboratory equipment due to its integrated refrigeration system and dual distillation setup. The design prioritizes stability and performance over portability, making it better suited for permanent lab installations. Our recommendation is to move the unit only when necessary and with proper lifting assistance or lab carts. Transporting it with care prevents damage to sensitive internal components.

  • Our Distillation Tester LDT-A16's refrigeration system is critical for maintaining the correct condenser temperature, which directly affects boiling point accuracy. We recommend immediately shutting down the system if cooling performance drops and inspecting it for compressor or refrigerant issues. Our support team or an authorized technician should be contacted for repairs. Routine maintenance of the condenser unit can help avoid unexpected failures.

  • Labtron Distillation Tester LDT-A16 may show irregular boiling if the heat setting or ramp rate is not properly adjusted. The unit should always be operated in accordance with ASTM D86 temperature guidelines to ensure consistent and accurate results. Our system provides precise heat control, so the power level must be carefully managed to avoid skewed data. Overheating or underheating can negatively affect both result quality and equipment longevity.

Post your question?

Our experts are here to help!

Distillation Tester:
Distillation Tester Front Type LDT-A14, Atmospheric Distillation Tester LDT-A22, Atmospheric Distillation Tester LDT-A20, Distillation Tester LDT-A10, Automatic Distillation Apparatus LDT-A21, Automated Atmospheric Distillation Tester LDT-A19, Benzene Distillation Tester (Low Temperature) LDT-A11, Distillation Tester LDT-A17, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608