Labtron Rotational Viscometer are engineered with a robust rotating spindle that interacts with the fluid. They come with multiple spindle options and variable speed settings to fit diverse testing requirements. These have simple calibration procedures and low maintenance needs. Their user-friendly controls guarantee ease of operation. Our rotational viscometer are enhanced by integrated temperature control, ensuring consistent sample conditions.
Measuring Range: 6 to 6,000,000 cP
Rotating Speed: 0.1 to 200 rpm
Measuring Error: ± 1 % full range (Newtonian liquid)
Repeatability Error: ± 0.5 %
Measurement Range: 1 to 2,000,000 mPa.s
Rotational Speed: 0.3 to 100 rpm per min
Rotors: Four rotors-No.1, No.2, No.3, No.4 (#0 is optional)
Measurement Accuracy: ± 1.0 % (of the full range)
Viscosity Range: 100 to 13M mPa·s
Rotation Speed Range: 0.3 to 100 rpm
Spindles: RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy: ± 1.0 % (of full range)
Viscosity Range: HA: 200 to 26000000 mPa.s
Rotation speed range: 0.3 to 100 rpm (stepless)
Spindles: HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy: ± 1.0 % (of full range)
Viscosity Range: HB: 800 to 104000000 mPa.s
Rotation speed range: 0.3 to 100 rpm (stepless)
Spindles: HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy: ± 1.0 % (of full range)
Viscosity Range: LV: 1 to 6000000 mPa.s
Rotation speed range: 0.1 to 250 rpm
Spindles: (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy: ± 1.0% (of full range)
Viscosity Range: RV: 100 to 40000000 mPa.s
Rotation speed range: 0.1 to 250 rpm
Spindles: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy: ± 1.0% (of full range)
Measurement Range: 200 to 80,000,000 mPa.s
Rotational Speed: 0.1 to 250 rpm per min
Rotors: No.2, No.3, No.4, No.5, No.6, No.7 (No.0 and No.1 is optional)
Measurement Accuracy: ± 1.0 % (of the full range)
Measurement Range: 800 to 320,000,000 mPa.s
Rotational Speed: 0.1 to 250 rpm per min
Rotors: No.2, No.3, No.4, No.5, No.6, No.7 (No.0 and No.1 is optional)
Measurement Accuracy: ± 1.0 % (of the full range)
Viscosity Range: 3 to 1600000 M (Mpa. S)
Rotation Speed Range: 0.3 / 0.6 / 1.5 / 3 / 6 / 10 / 12 / 15 / 20 / 25 / 30 / 40 / 50 / 60 / 70 / 80 / 90 / 100 Total 18 rpm
Spindles: 18# rotor:3 to 10 K 7 ml25# rotor:480 to 1.6 M 9 ml31# rotor:30 to 100 10.5 ml34# rotor:60 to 200 K 11 ml
Rotor: 18#,25#,31#,34# (standard configuration)
Rotational Speed Range: 0.3 to 100 rpm
Measurement Error: ± 1 %
Repetitive Error: ± 0.5 %
Standard Rotor: Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
Rotational Speed Range: 0.3 to 100 rpm
Measurement Error: ± 1 %
Repetitive Error: ± 0.5 %
Standard Rotor: Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
Measuring Range: 0.1 to 100,000 Mpa. S
Measuring Error: ±1% (Newtonian Liquid)
Rotating Speed: 6 / 12 / 30 / 60 (r/min)
Rotor: 1-4 rotors, (0 rotor for low viscosity)
Measuring Range: 0.1 to 2,000,000 Mpa. S
Measuring Error: ±1% (Newtonian liquid)
Rotating Speed: 0.3 / 0.6 / 1.5 / 3 / 6 / 12 / 30 / 60 (r/min)
Rotor: Rotors 1-4; 0 rotor required for viscosity below 10 Mpa. S
Measurement Range: 10 to 100,000 mPa.s
Measurement Accuracy: ± 1.0 % (Newtonian fluids)
Rotors: No.1, No.2, No.3, No.4 (Optional No.0)
Rotate Speed: 6 / 12 / 30 / 60 / (r/min)
Measurement Range: 10 to 2,000,000 (10⁶) mPa.s
Measurement Accuracy: ± 1.0 % (Newtonian fluids)
Rotors: No.1, No.2, No.3, No.4 (optional No.0)
Rotate Speed: 0.3 / 0.6 / 1.5 / 3 / 6 / 12 / 30 / 60 r/min
Measurement Range: 5 to 330k mPa.s 50 to 3.3M mPa.s 100 to 6.6M mPa.s400 to 26.4M mPa.s
Rotors: SC4-21#, 27#, 28#, 29# (14, 15, 116, 18, 25, 31, 34 is optional)
Rotational Speed: 0.3 to 100 rpm per min
Measurement Accuracy: ± 1.0 % (of the full range)
Measurement Range: 5 to 1,000,000 mPa.s 25 to 10,000,000 mPa.s 50 to 20,000,000 mPa.s200 to 80,000,000 mPa.s
Rotational Speed: 0.1 to 200 rpm per min
Rotors: SC4-21#, 27#, 28#, 29# (14, 15, 116, 18, 25, 31, 34 is optional)
Measurement Accuracy: ± 1.0 % (of the full range)
Measuring Range mPa.s: 50000 to 330000 50 to 3.3M100 to 6.6M 600 to 26.4M
Temperature Control Range: 1°C to 150°C
Rotor Speed (RPM): 0.3 to100
Numbers of Rotors: Four kinds of standard configuration: SC4-21, 27, 28,29.
Measuring range: 1 to 100000 Mpa. S
Measuring Error: ±1% (Newtonian liquid)
Rotating speed: 3 / 6 / 12 / 30 / 60 (r/min)
Rotor: 1-4 rotors (lower than 10 Mpa. S needs 0 rotor)
Measuring Range: 1 to 100000 Mpa. S
Measuring Error: ±0.5% (Newtonian liquid)
Rotating Speed: 3 / 6 / 12 / 30 / 60 (r/min)
Rotor: 1 to 4 number rotors require a 0 number rotor for viscosity lower than 10 Mpa. S
Measuring range: 1 to 200000 mPa.s
Rotating speed: 0.3/0.6/1.5/3.6/12/30/60 (r/min)
Rotor: 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid): ±1%
Measuring range: 1 to 600000 mPa.s
Rotating speed: 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor: 1 to 4 number rotors
Measuring Error (Newtonian liquid): ±1%
Measurement range: 25 mPa.s to 1×10000000 mPa.s
Rotors: Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed: (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range: 45 to 200°C
Measurement range: 100 mPa.s to 200000 mPa.s
Rotors: Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed: 5, 10, 20, 50 r/min
Temperature control range: Room temperature to 200°C
Measurement range: 100 mPa.s to 2000000 mPa.s
Rotors: Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed: 5, 10, 20, 50 r/min
Temperature control range: 45 to 200°C
Viscosity Range: 40.2 KU to 141.0 KU32 g to 1099 g27 to 5250 CP
Rotation speed range: 200±0.1 rpm
Accuracy: ± 3 %
Repeatability: ±1.5 %
Measurement range: 25 mPa.s to 1 × 107 mPa.s
Rotors: Rotor no. 21, 27, 28, 29 (total 4 pieces of spindles)
Rotation speed: 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100 and 200 rpm
Temperature control range: 45 to 200°C
Measuring Range: 100 to 2 × 10⁵ mPa.s
Rotor Size: 27 No. rotor (21, 28, 29 rotor is optional)
Rotor Speed: 5 r/ min, 10 r/ min, 20 r / min, 50 r/ min
Rotational Speed: 10 to 200 rpm
Cooling Bath Capacity: 8L
Temperature Range: Ambient to 50℃
Temperature Accuracy: ±0.1℃
Ambient Temperature: 5℃ to 40℃
Measurement Range: 10 to100,000 mPa.s (cP)
Rotor: No. 1, No. 2, No. 3, No. 4 (Four Rotors)
Rotor Speed: 6 r/min, 12 r/min, 30 r/min, 60 r/min
Measure: Newtonian fluids
Measurement Range: Medium Viscosity Sample: 50 to 10M (mPa. s/cP) Low Viscosity Sample: 5 to 1M (mPa. s/Cp)
Rotors: SC4-21#, 27#, 28#, 29# four spindles Optional: SC4- 14, 15, 16, 18, 25, 31, 34
Rotation Speed: 0.1 to 200 RPM
Measurement Accuracy: ± 1.0 %
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom