| Capacity | 408 L |
| Temperature Range | - 70 ℃ to + 150 ℃ (Optional + 180 ℃) |
| Temperature Uniformity | ± 2.0 °C |
| Temperature Fluctuation | ± 0.5 ℃ |
| Temperature Deviation | ± 2.0 ℃ |
| Temperature Resolution | + 0.1 ℃ |
| Heating Rate | - 70 ℃ to + 100 ℃ |
| Cooling Rate | + 20 ℃ to – 70 ℃ |
| Humidity Range | 20 % to 98 % R.H |
| Humidity Uniformity | ± 3 % R.H |
| Humidity Fluctuation | ± 2.0 % R.H |
| Humidity Deviation | ±3.0 % / 5.0 % R.H |
| Humidity Resolution | + 0.1 % |
| Ambient Temperature | 5 °C to 35 °C |
| Humidifier Type | Stainless-steel electric heating humidifier |
| Compressor | Copeland or Tecumseh or Sanyo compressor |
| Controller | 7-inch touch screen controller |
| Centrifugal Blower | Multi-wings centrifugal blowers with aluminum alloy blades |
| Display Type | 7-inch LED touch screen |
| Communication Interface | USB, RS-485, and WLAN (Optional) |
| Evaporator | High efficiency multi-stage fin type evaporator |
| Refrigeration System | Single stage refrigeration system with R404A refrigerant |
| Drainage Port | φ10 Plug and Play soft silicone pipe drain water out of the chamber |
| Noise | ≦ 75 (dB) |
| Exterior Chamber Material | High-quality carbon steel with painting |
| Interior Chamber Material | SUS304 matte stainless-steel plate |
| Insulation Material | Rigid polyurethane foam insulation, flame retardant grade B2 |
| Power Consumption | 6 KW |
| Power supply | AC 380V ±10% 50Hz / AC 220V ±10% 50Hz |
| Internal Dimensions | 700 × 750 × 800 mm |
| External Dimensions | 900 × 1715 × 1790 mm |
| Package Dimensions | 1140 × 2240 × 2150 mm |
| Net Weight | 872 Kg |
| Gross Weight | 972 Kg |
Door Handle Accessibility
Control Desk Features
Malfunction Recording Software
Humidity Ramp Control
Date Export Options
Our chamber is widely used in aerospace, electronics, pharmaceuticals, and automobile industries, as well as for environmental stress screening, quality assurance, material testing, and performance evaluation under extreme conditions.
Standard Accessories:
Accessories | Quantity | Unit |
Window light | 1 | Set |
Mobile casters (with foot cups) | 4 | Pieces |
50mm lead holes (with silicone plugs) | 2 | Units |
Sample racks | 2 | Layers |
Lighting set | 1 | Set |
Power cord | 5 | Meters |
Shelves
Download catalog for
Temperature And Humidity Test Chamber LTHC-H23 Catalog
Available Range :
Temperature and Humidity Test Chamber LTHC-B10 : 100 L Temperature and Humidity Test Chamber LTHC-B14 : 1000 L Temperature And Humidity Test Chamber LTHC-E11 : 105 L Temperature and Humidity Test Chamber LTHC-D11 : 1130L Temperature And Humidity Test Chamber LTHC-A14 : 120L Temperature and Humidity Test Chamber LTHC-C20 : 150 L Temperature and Humidity Test Chamber LTHC-B25 : 1500 L Temperature and Humidity Test Chamber LTHC-B11 : 225 L Temperature And Humidity Test Chamber LTHC-A15 : 225L Temperature and Humidity Test Chamber LTHC-A12 : 250 L Temperature And Humidity Test Chamber LTHC-J10 : 27L Temperature and Humidity Test Chamber LTHC-D10 : 300L Temperature and Humidity Test Chamber LTHC-B30 : 3150 L Temperature And Humidity Test Chamber LTHC-E13 : 408 L Temperature And Humidity Test Chamber LTHC-A10 : 50 L Temperature and Humidity Test Chamber LTHC-B12 : 500 L Temperature And Humidity Test Chamber LTHC-A16 : 504L Temperature and Humidity Test Chamber LTHC-C30 : 550L Temperature And Humidity Test Chamber LTHC-A13 : 64 L Temperature And Humidity Test Chamber LTHC-A11 : 80 L Temperature and Humidity Test Chamber LTHC-B13 : 800 L Temperature And Humidity Chamber LTHC-G10 : Total of 500L Temperature And Humidity Chamber LTHC-G11 : Total of 800L
Labtron offers temperature and humidity test chambers with capacities ranging from 50 to 1130 L. They have a humidity controller and thermal-insulating material resistant to high temperatures. They feature an LCD touch screen with a corrosion-resistant interior chamber and a double-layered glass observation window. They include an independent R&D software and a compressor overload switch. Our temperature and humidity tester has built-in safety self-protection and overheating prevention.




.webp)

.webp)

Yes, multiple samples can be tested simultaneously; however, proper spacing between items is crucial to ensure free airflow and consistent exposure. Overloading or stacking samples may lead to uneven temperature and humidity distribution. Adjustable stainless-steel shelves are typically included to help organize multiple test items efficiently. Each sample should be placed to avoid blocking sensors, vents, or other items. When testing different materials, ensure they are compatible and do not interfere with one another. Following best loading practices ensures valid, repeatable, and reliable test results.
The Temperature and Humidity Test Chamber LTHC-H23 typically operates at noise levels between 60 and 75 dB. Most of the sound comes from the refrigeration system, circulation fan, and internal mechanical components. While not extremely loud, the noise may be noticeable in quiet laboratory environments. Some models are engineered with sound-insulated panels or vibration-dampening features to reduce noise. Noise levels may increase slightly during rapid heating or cooling phases. It is advisable to place the chamber in a semi-isolated space if minimal noise is desired. Manufacturers generally specify the noise rating in the product's technical datasheet.
Over-temperature protection is a critical safety feature that prevents the chamber from exceeding its maximum temperature limits. It automatically shuts off the heating system or activates an alarm if readings go beyond safe thresholds. This helps protect both the test samples and internal components from thermal damage. Over-temperature protection is especially important during unattended or long-duration testing. It is typically managed by electronic controllers or mechanical thermostats. Some advanced models include dual-layer protection systems for added reliability. This function ensures operational safety, performance stability, and user confidence.
The Temperature and Humidity Test Chamber LTHC-H23 can last between 8 and 15 years or more. Its lifespan depends on usage frequency, environmental conditions, and proper maintenance. Critical components such as compressors, humidifiers, and controllers may require periodic servicing or replacement. Chambers from reputable manufacturers generally offer longer service life and superior build quality. Adhering to the manufacturer’s maintenance guidelines helps extend durability and ensure consistent performance. Routine calibration, inspection, and cleaning are essential for optimal operation. Investing in a high-quality chamber reduces long-term maintenance and operational costs.
Yes, the Temperature and Humidity Test Chamber LTHC-H23 is designed to integrate with external devices and systems. It typically includes ports like RS232, RS485, USB, or Ethernet for communication with data loggers, computers, or control units. Integration allows real-time monitoring, test automation, and synchronization with other equipment. For instance, a vibration table or external power supply can be linked for combined mechanical and environmental testing. Manufacturer-provided software platforms often support centralized device control and test scheduling. Some models also enable remote access via cloud services or mobile apps. This integration improves testing flexibility, efficiency, and traceability.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608