Benchtop Conductivity Meter

Labtron Benchtop Conductivity Meter is specialized to measure ion concentration with conductivity of 0 to 3000 mS/cm in liquid samples. Their probes are highly sensitive and provide reliable assessment. They feature automatic temperature compensation to ensure accurate results regardless of fluctuation. Their self-diagnostic system monitors the functionality of meter and alert users to any issues. Our Benchtop Conductivity Meter is versatile for chemical analysis, pharmaceutical and agriculture ensuring water quality testing.

Filter

Clear All

Water Testing Equipment

Conductivity measurement range

Conductivity accuracy

Conductivity resolution

Conductivity calibration solutions

Benchtop conductivity meter LBCM-A11

Benchtop conductivity meter LBCM-A11

Conductivity measurement range: 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm

Conductivity accuracy: ± 1 % F.S.

Conductivity resolution: 0.01, 0.1, 1

Conductivity calibration solutions: 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm

Benchtop Conductivity Meter LBCM-A12

Benchtop Conductivity Meter LBCM-A12

Conductivity Range: 0.000 µS/cm to 3000 mS/cm

Conductivity Resolution: 0.001 µS/cm minimum

Conductivity Accuracy: ±0.5% FS

Conductivity Reference Temperature: 5, 10, 15, 18, 20, 25 ºC

Benchtop Conductivity Meter LBCM-A13

Benchtop Conductivity Meter LBCM-A13

Conductivity measurement range: 0.000 μS/cm to 3000mS/cm

Resistivity measurement range: 5.00 Ω·cm to 100.0 MΩ·cm

TDS measurement range: 0.000 mg/L to 1000g/L

Salinity measurement range: 0.00 to 8.00 %

Benchtop Conductivity Meter LBCM-A14
Benchtop Conductivity Meter LBCM-A14

Conductivity Mode: Conductivity measurement range0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cmConductivity accuracy±1% F.S.Conductivity resolution0.001, 0.01, 0.1, 1Conductivity calibration points1 to 3 pointsConductivity calibration solutions10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm

TDS Mode: TDS measurement Range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS Accuracy± 1 % F.S.TDS Factor0.01 to 1.00 (default 0.5)TDS Calibration points3 points

Temperature Mode: Temperature range0 to 105°C, 32 to 221°FTemperature accuracy±1°CTemperature resolution0.1°C, 0.1°FTemperature calibration points1 pointTemperature Compensation Range and ModeManual or Automatic, 0 to 100°C , 32 to 212°FTemperature coefficient0.0 to 10.0 % per °C

Cell constant: K=0.1, 1, 10

Benchtop Conductivity Meter LBCM-B10
Benchtop Conductivity Meter LBCM-B10

Conductivity measurement range: 0.0000 to 400.0 mS/cm

TDS measurement range: 0.0000 ppm to 200.0 ppt

Salinity measurement range: 0.0 to 260.0 g/L

Conductivity accuracy: ±0.5% FS


Benchtop Conductivity Meter :
Benchtop conductivity meter LBCM-A11, Benchtop Conductivity Meter LBCM-A12, Benchtop Conductivity Meter LBCM-A13, Benchtop Conductivity Meter LBCM-A14, Benchtop Conductivity Meter LBCM-B10, and more.

Quick Links : About Us, Contact Us, User Manuals, Career, Terms of Use, Policies, Sitemap, Gallery.

Need a Product

send details for best price quotation

Click
For

Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.