Benchtop Conductivity Meter LBCM-A12

Benchtop Conductivity Meter LBCM-A12

Benchtop Conductivity Meter LBCM-A12 can measure the conductivity of water in a range of 0.000 µS/cm to 3000 mS/cm. Its intelligent operation system provides features for user, calibration, method, and data management. Temperature compensation options include none, linear, and pure water. The multi-reading function allows auto-read, timed-read, and continuous-read options. Our conductivity meter offers both automatic and manual temperature compensation ensuring accurate results.
Request Quote
Conductivity Range 0.000 µS/cm to 3000 mS/cm
Conductivity Resolution 0.001 µS/cm minimum
Conductivity Accuracy ±0.5% FS
Conductivity Reference Temperature 5, 10, 15, 18, 20, 25 ºC
Conductivity Calibration Points Up to 5
Conductivity Standard Recognition 146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm
Resistivity Range 5.00 Ω·cm to 100.00 MΩ·cm
Resistivity Resolution 0.01 Ω·cm
Resistivity Accuracy ±0.5% FS
TDS Range 0.000 mg/L to 1000 g/L
TDS Resolution 0.001ppm minimum
TDS Accuracy ±0.5%FS
Salinity Type NaCl%
Salinity Range (0.00 to 8.00) %
Salinity Resolution 0.0001
Salinity Accuracy ±0.1%
Temperature Range -5 to 130 ºC
Temperature Unit ºC
Temperature Resolution 0.1 ºC
Temperature Accuracy ±0.1 ºC
Measurement Reading Mode Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts Reading, Stable, Locked
Temp. Compensation ATC, MTC
Data Storage 1000 Groups
GLP Features Yes
Log Management Yes
Temp. Probe 6-pin Mini-DIN
Conductivity Probe 8-pin Mini-DIN
Outputs USB, RS 232
Connection USB 2.0 flash memory device, printer, PC
Backlight Display yes
Auto Shutdown 1 to 60 min, off
IP Rating IP54
Date and Time Yes
Power Supply AC Adapter, 100-240V AC input,DC24V output
Dimensions 280 × 280 × 130 mm
Weight 2.5 Kg
  • Stores up to 1000 sets of data for each parameter
  • Data analysis feature to review, compare, and recalculate results
  • Supports communication via USB or RS-232
  • The reset function restores all settings
  • IP54-rated for water resistance
  • 7.0-inch-high contrast color LCD touchscreen
  • 1 to 5 points calibration with standard recognition
Our conductivity meter is employed for high-end water quality management and automatic control of systems such as medical multi-effect distilled water, boiler feedwater, condensate water, and heat exchange systems operating in high-temperature environments.
Conductivity Electrode
Temperature Probe GM65-240270
AC/DC Power Adapter
Electrode Stand
Touch Pen
Dust Cover
Mini USB Communication Cable
European Standard Power Cord
Ground Wire
Instruction Manual
Operation Guide

Models of Benchtop Conductivity Meter

Labtron Benchtop Conductivity Meter is specialized to measure ion concentration with conductivity of 0 to 3000 mS/cm in liquid samples. Their probes are highly sensitive and provide reliable assessment. They feature automatic temperature compensation to ensure accurate results regardless of fluctuation. Their self-diagnostic system monitors the functionality of meter and alert users to any issues. Our Benchtop Conductivity Meter is versatile for chemical analysis, pharmaceutical and agriculture ensuring water quality testing.

Benchtop Conductivity Meter LBCM-B10

Benchtop Conductivity Meter LBCM-B10

  • Conductivity measurement range : 0.0000 to 400.0 mS/cm
  • TDS measurement range : 0.0000 ppm to 200.0 ppt
  • Salinity measurement range : 0.0 to 260.0 g/L
  • Conductivity accuracy : ±0.5% FS
Benchtop conductivity meter LBCM-A11

Benchtop conductivity meter LBCM-A11

  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.
  • Conductivity resolution : 0.01, 0.1, 1
  • Conductivity calibration solutions : 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14

  • Conductivity Mode : Conductivity measurement range0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cmConductivity accuracy±1% F.S.Conductivity resolution0.001, 0.01, 0.1, 1Conductivity calibration points1 to 3 pointsConductivity calibration solutions10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
  • TDS Mode : TDS measurement Range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS Accuracy± 1 % F.S.TDS Factor0.01 to 1.00 (default 0.5)TDS Calibration points3 points
  • Temperature Mode : Temperature range0 to 105°C, 32 to 221°FTemperature accuracy±1°CTemperature resolution0.1°C, 0.1°FTemperature calibration points1 pointTemperature Compensation Range and ModeManual or Automatic, 0 to 100°C , 32 to 212°FTemperature coefficient0.0 to 10.0 % per °C
  • Cell constant : K=0.1, 1, 10
Benchtop Conductivity Meter LBCM-A13
Benchtop Conductivity Meter LBCM-A13
  • Conductivity measurement range : 0.000 μS/cm to 3000mS/cm
  • Resistivity measurement range : 5.00 Ω·cm to 100.0 MΩ·cm
  • TDS measurement range : 0.000 mg/L to 1000g/L
  • Salinity measurement range : 0.00 to 8.00 %
Benchtop Conductivity Meter LBCM-C10
Benchtop Conductivity Meter LBCM-C10
  • Conductivity Measuring Range : (0.00 to 20.00)μS/cm, (20.0 to 200.0)μS/cm(200 to 2000)μS/cm, (2.00 to 20.00)mS/cm(20.0 to 200.0)mS/cm(200 to 2000)mS/cm (K=10)TDS: 0 to 100 g/LSalinity: 0 to 100 pptResistivity: 0 to 100 MΩ·cm
  • Conductivity Resolution : 0.01/0.1/1μS/cm; 0.01/0.1/1mS/cm
  • Conductivity Accuracy : Electrode: ± 0.5% F S, Meter: ± 0.80% F S
  • Conductivity Temperature Compensation : 0 to 100℃, auto

Benchtop Conductivity Meter:
Benchtop Conductivity Meter LBCM-B10, Benchtop conductivity meter LBCM-A11, Benchtop Conductivity Meter LBCM-A14, Benchtop Conductivity Meter LBCM-A13, Benchtop Conductivity Meter LBCM-C10, and more.

Quick Links : About Us, Contact Us, User Manuals, Career, Terms of Use, Policies, Sitemap, Gallery.

Need a Product

send details for best price quotation

Click
For

Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.