Request A Quote
Benchtop Conductivity Meter LBCM-B10

Benchtop Conductivity Meter LBCM-B10

Benchtop Conductivity Meter LBCM-B10 features a conductivity measurement range of water from 0.0000 to 400.0 mS/cm. It also measures TDS from 0.0000 ppm to 200.0 ppt with high accuracy. The device includes an easy-to-read data interface with excellent anti-interference performance for reliable measurements. With an IP65 protection level, the meter is built for durability in various environments. Perfect for laboratories and water treatment facilities where accurate water quality testing and analysis are essential.

Benchtop Conductivity Meter LBCM-B10
Benchtop Conductivity Meter LBCM-B10
Benchtop Conductivity Meter LBCM-B10
Benchtop Conductivity Meter LBCM-B10
Benchtop Conductivity Meter LBCM-B10
Request Quote
Conductivity measurement range 0.0000 to 400.0 mS/cm
TDS measurement range 0.0000 ppm to 200.0 ppt
Salinity measurement range 0.0 to 260.0 g/L
Conductivity accuracy ±0.5% FS
TDS accuracy ±0.5% FS
Salinity accuracy ±0.5% FS
Protection level IP65
Power supply DC 12V
Dimension 220 × 120 × 70 mm
Net weight 0.8 kg
  • Advanced sensor technology

  • Automatic range adjustment

  • Durable, waterproof design

  • High-brightness backlighting

  • Data locking capability

  • Easy calibration process

Our Benchtop Conductivity Meter LBCM-B10 is perfect for testing water quality in labs and educational settings, offering accurate conductivity, TDS, and salinity measurements for research.

Models of Benchtop Conductivity Meter

Labtron Benchtop Conductivity Meter is specialized to measure ion concentration with conductivity of 0 to 3000 mS/cm in liquid samples. Their probes are highly sensitive and provide reliable assessment. They feature automatic temperature compensation to ensure accurate results regardless of fluctuation. Their self-diagnostic system monitors the functionality of meter and alert users to any issues. Our Benchtop Conductivity Meter is versatile for chemical analysis, pharmaceutical and agriculture ensuring water quality testing.

Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14

  • Conductivity Mode : Conductivity measurement range0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cmConductivity accuracy±1% F.S.Conductivity resolution0.001, 0.01, 0.1, 1Conductivity calibration points1 to 3 pointsConductivity calibration solutions10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
  • TDS Mode : TDS measurement Range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS Accuracy± 1 % F.S.TDS Factor0.01 to 1.00 (default 0.5)TDS Calibration points3 points
  • Temperature Mode : Temperature range0 to 105°C, 32 to 221°FTemperature accuracy±1°CTemperature resolution0.1°C, 0.1°FTemperature calibration points1 pointTemperature Compensation Range and ModeManual or Automatic, 0 to 100°C , 32 to 212°FTemperature coefficient0.0 to 10.0 % per °C
  • Cell constant : K=0.1, 1, 10
Benchtop Conductivity Meter LBCM-D10

Benchtop Conductivity Meter LBCM-D10

  • Conductivity Range : 0.00 µ S / cm to 200.0 S / cm
  • Resolution : 0.01µ S / cm minimum
  • Accuracy : ± 1.0 % F, S
  • Temperature Range : -5.0.0° C to 110.0℃
Benchtop Conductivity Meter LBCM-A12

Benchtop Conductivity Meter LBCM-A12

  • Conductivity Range : 0.000 µS/cm to 3000 mS/cm
  • Conductivity Resolution : 0.001 µS/cm minimum
  • Conductivity Accuracy : ±0.5% FS
  • Conductivity Reference Temperature : 5, 10, 15, 18, 20, 25 ºC
Benchtop conductivity meter LBCM-A11
Benchtop conductivity meter LBCM-A11
  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.
  • Conductivity resolution : 0.01, 0.1, 1
  • Conductivity calibration solutions : 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Benchtop Conductivity Meter LBCM-C10
Benchtop Conductivity Meter LBCM-C10
  • Conductivity Measuring Range : (0.00 to 20.00)μS/cm, (20.0 to 200.0)μS/cm(200 to 2000)μS/cm, (2.00 to 20.00)mS/cm(20.0 to 200.0)mS/cm(200 to 2000)mS/cm (K=10)TDS: 0 to 100 g/LSalinity: 0 to 100 pptResistivity: 0 to 100 MΩ·cm
  • Conductivity Resolution : 0.01/0.1/1μS/cm; 0.01/0.1/1mS/cm
  • Conductivity Accuracy : Electrode: ± 0.5% F S, Meter: ± 0.80% F S
  • Conductivity Temperature Compensation : 0 to 100℃, auto
Benchtop Conductivity Meter LBCM-A13

Benchtop Conductivity Meter LBCM-A13

  • Conductivity measurement range : 0.000 μS/cm to 3000mS/cm
  • Resistivity measurement range : 5.00 Ω·cm to 100.0 MΩ·cm
  • TDS measurement range : 0.000 mg/L to 1000g/L
  • Salinity measurement range : 0.00 to 8.00 %

Benchtop Conductivity Meter:
Benchtop Conductivity Meter LBCM-A14, Benchtop Conductivity Meter LBCM-D10, Benchtop Conductivity Meter LBCM-A12, Benchtop conductivity meter LBCM-A11, Benchtop Conductivity Meter LBCM-C10, Benchtop Conductivity Meter LBCM-A13, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom