Jacketed Glass Reactor LJGR-A26 features a 100 L cylindrical glass vessel, supporting high-volume experiments requiring consistent thermal control. Its wide lid design simplifies reagent loading and internal maintenance. The built-in vacuum function stabilizes internal conditions for low-pressure reactions. Our Glass Reactor is ideal for synthesis, distillation, and concentration in chemical, pharmaceutical, and academic laboratories. 

Jacketed Glass Reactor LJGR-A26
Jacketed Glass Reactor LJGR-A26
Jacketed Glass Reactor LJGR-A26
Jacketed Glass Reactor LJGR-A26
Jacketed Glass Reactor LJGR-A26
Request Quote
Glass Vessel Volume 100 L Cylindrical
Glass Vessel Lid Diameter Φ 340 mm
Jacketed Volume 20000 ml
Dropping Funnel 2000 ml
Temperature Range -80℃ to 250℃
Temperature Measurement Accuracy +/-1℃
Stirring Speed 0 to 450 rpm
Vacuum Degree 0.0098 Mpa
Power Consumption 200 W
Power Supply 220V/50Hz
Condenser Dimension (D×H) 100×700 mm
Dimensions (W×D×H) 950×750×2390 mm
Weight 95 kg
  • Adjustable digital speed controller

  • Corrosion-resistant stirring shaft

  • High-clarity glass structure

  • Durable stainless steel frame

  • Integrated condenser for cooling

Jacketed Glass Reactor LJGR-A26 is designed to facilitate controlled chemical reactions, temperature-sensitive processes, and sample preparation in laboratory-scale research. The system supports mixing, thermal exchange, and vacuum operations for pharmaceutical, petrochemical, and material development tasks.

Models of Jacketed Glass Reactor

Jacketed Glass Reactor supports controlled mixing with adjustable stirring speed, ensuring consistent reaction dynamics in varied experiments. They maintain thermal stability using a jacketed layer for fluid circulation without exposing the medium. Their borosilicate glass build withstands thermal stress and chemical exposure over time. These systems include a display panel for monitoring key parameters during operation. Our glass reactor is suited for synthesis, distillation, extraction, crystallization, and pharmaceutical development.

Jacketed Glass Reactor LJGR-B17

Jacketed Glass Reactor LJGR-B17

  • Glass Vessel Volume : 50 L Cylindrical
  • Dropping Funnel Volume : 2000 mL
  • Dropping Funnel Interface : 40/38
  • Glass Vessel Flange : Φ 215 mm
Jacketed Glass Reactor LJGR-A22

Jacketed Glass Reactor LJGR-A22

  • Glass Vessel Volume : 10 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 265 mm
  • Jacketed Volume : 3000 ml
  • Dropping Funnel : 1000 ml
Jacketed Glass Reactor LJGR-B12

Jacketed Glass Reactor LJGR-B12

  • Glass Vessel Volume : 20 L Cylindrical
  • Dropping Funnel Volume : 2000 ml
  • Dropping Funnel Interface : 40/38
  • Glass Vessel Flange : Φ 215 mm
Jacketed Glass Reactor LJGR-A17
Jacketed Glass Reactor LJGR-A17
  • Glass Vessel Volume : 5 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 205 mm
  • Jacketed Volume : 800 ml
  • Dropping Funnel : 500 ml
Jacketed Glass Reactor LJGR-B24
Jacketed Glass Reactor LJGR-B24
  • Glass Vessel Volume : 100 L
  • Jacketed Volume : 18 L
  • Flanged out of the oil circulation port : Low feed high outlet
  • Reaction bottle cover : Six port
Jacketed Glass Reactor LJGR-A36

Jacketed Glass Reactor LJGR-A36

  • Glass Vessel Volume : 5 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 205 mm
  • Jacketed Volume : 800 ml
  • Dropping Funnel : 50 ml
Jacketed Glass Reactor LJGR-A44

Jacketed Glass Reactor LJGR-A44

  • Glass Vessel Volume : 50 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 265 mm
  • Jacketed Volume : 16000 ml
  • Dropping Funnel : 2000 ml
Jacketed Glass Reactor LJGR-A32

Jacketed Glass Reactor LJGR-A32

  • Glass Vessel Volume : 50 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 265 mm
  • Jacketed Volume : 7000 ml
  • Dropping Funnel : 1000 ml

Jacketed Glass Reactor LJGR-A26 FAQ's
  • Our Jacketed Glass Reactor is well-suited for extended experimental procedures where reaction consistency must be maintained over time. The thermal jacket minimizes fluctuation, helping to sustain a defined environment throughout prolonged processes. Its sturdy framework supports uninterrupted operation without compromising stability or safety. Stirring control also ensures reactants remain uniformly distributed during longer durations. Since reaction timing can vary widely in research, the setup is designed for dependable runtime handling. Many labs use this reactor for complex syntheses that cannot tolerate external interruptions. Its cooling and heating capabilities remain effective across extended sessions. This helps researchers confidently run processes without intervention.

  • The Jacketed Glass Reactor is engineered with chemical durability in mind, especially for use in corrosive reaction environments. Its construction materials were selected specifically to withstand aggressive reagents and reactive media commonly used in lab synthesis. The entire vessel and contact parts provide protection against deterioration caused by acids, solvents, and oxidizers. This makes it suitable for demanding applications in chemical engineering and bio-pharmaceutical labs. By avoiding material degradation, the reactor helps ensure purity and reliability in the outcome. Its setup is often preferred in protocols involving volatile or reactive agents. The interior surface maintains integrity during complex transformations. Our reactor supports both safety and performance in harsh chemical workflows.

  • Labtron’s Jacketed Glass Reactor offers optimal conditions for processing viscous mixtures without manual intervention. Its stirring mechanism allows even thick or semi-solid materials to be consistently agitated without sticking or settling. The build of the vessel and the motor-driven mixer are designed to work together across various material consistencies. This supports experiments involving polymerization, emulsions, or resins. The stirring system operates across a wide torque range to accommodate fluid resistance. Lab users benefit from consistent mixing and improved heat transfer, even with heavy samples. Its design reduces the chances of blockages or uneven distribution. Our unit is a dependable tool for handling non-Newtonian or dense fluids.

  • The Jacketed Glass Reactor includes a wide-top access port that allows scientists to safely insert tools, probes, or sampling devices during ongoing reactions. This is particularly useful in workflows requiring regular observation or small additions of reagents. Its layout is helpful in titration, process testing, or real-time monitoring. Users can conduct mid-process measurements or pH adjustments without halting the reaction. Handling of glassware or pipettes is made safer due to improved access space. This configuration also supports experiments that require staggered dosing schedules. By avoiding full disassembly, process continuity is preserved. Our reactor facilitates active engagement during lab procedures.

  • Our Jacketed Glass Reactor was developed with multi-use practicality in mind, particularly for labs performing several runs using different compounds. The vessel’s cylindrical design allows easy reach to interior surfaces for cleaning or inspection. Its removable fittings and wide lid make it less time-consuming to rinse or swap out components. Users avoid contamination by being able to reset the chamber quickly between tests. This is beneficial in academic, pharma, or research settings where cross-sample integrity is critical. Components that contact chemicals are designed for easy disassembly. Its smooth inner surface minimizes retention of residue. Our system ensures fast turnaround for high-throughput labs.

  • The Jacketed Glass Reactor is compatible with various lab monitoring tools and add-ons, allowing users to integrate digital sensors or controllers. Researchers needing to track variables such as temperature, pH, or stirring speed digitally can do so through external modules. The design allows placement of probes without structural modifications. This expands its utility for data-logging, automated reaction timing, or smart lab integration. Automated dosing or real-time feedback becomes easier with open access and modular ports. Labs benefit from less manual oversight and improved consistency. Our system is built with flexibility in mind for modern lab workflows.

Post your question?

Our experts are here to help!

Jacketed Glass Reactor:
Jacketed Glass Reactor LJGR-B17, Jacketed Glass Reactor LJGR-A22, Jacketed Glass Reactor LJGR-B12, Jacketed Glass Reactor LJGR-A17, Jacketed Glass Reactor LJGR-B24, Jacketed Glass Reactor LJGR-A36, Jacketed Glass Reactor LJGR-A44, Jacketed Glass Reactor LJGR-A32, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.