| Glass Vessel Volume | 50 L Cylindrical |
| Glass Vessel Lid Diameter | Φ 265 mm |
| Jacketed Volume | 16000 ml |
| Dropping Funnel | 2000 ml |
| Temperature Range | -80℃ to 250℃ |
| Temperature Measurement Accuracy | +/-1℃ |
| Stirring Speed | 0 to 450 rpm |
| Vacuum Degree | 0.0098 Mpa |
| Power Consumption | 120 W |
| Power Supply | 220V/50Hz |
| Condenser Dimension (D×H) | 100×700 mm |
| Dimensions (W×D×H) | 870×560×2270 mm |
| Weight | 67 kg |
Jacketed Glass Reactor LJGR-A25 controls reaction temperature with its dual-layer jacket system, ensuring steady conditions for synthesis, distillation, and concentration. It supports research labs, chemical engineering, and pilot-scale production in various industries.
Download catalog for
Jacketed Glass Reactor LJGR-A25 Catalog
Available Range :
Jacketed Glass Reactor LJGR-A10 : 1 L Cylindrical Jacketed Glass Reactor LJGR-B21 : 10 L Jacketed Glass Reactor LJGR-A22 : 10 L Cylindrical Jacketed Glass Reactor LJGR-B24 : 100 L Jacketed Glass Reactor LJGR-A26 : 100 L Cylindrical Jacketed Glass Reactor LJGR-B26 : 100L Jacketed Glass Reactor LJGR-A27 : 150 L Cylindrical Jacketed Glass Reactor LJGR-A11 : 2 L Cylindrical Jacketed Glass Reactor LJGR-B22 : 20 L Jacketed Glass Reactor LJGR-A23 : 20 L Cylindrical Jacketed Glass Reactor LJGR-B25 : 200 L Jacketed Glass Reactor LJGR-A28 : 200 L Cylindrical Jacketed Glass Reactor LJGR-A12 : 3 L Cylindrical Jacketed Glass Reactor LJGR-A24 : 30 L Cylindrical Jacketed Glass Reactor LJGR-B20 : 5 L Jacketed Glass Reactor LJGR-A50 : 5 L (Cylindrical) Jacketed Glass Reactor LJGR-A17 : 5 L Cylindrical Jacketed Glass Reactor LJGR-A13 : 5 L, Cylindrical Jacketed Glass Reactor LJGR-B23 : 50 L Jacketed Glass Reactor LJGR-A25 : 50 L CylindricalJacketed Glass Reactor supports controlled mixing with adjustable stirring speed, ensuring consistent reaction dynamics in varied experiments. They maintain thermal stability using a jacketed layer for fluid circulation without exposing the medium. Their borosilicate glass build withstands thermal stress and chemical exposure over time. These systems include a display panel for monitoring key parameters during operation. Our glass reactor is suited for synthesis, distillation, extraction, crystallization, and pharmaceutical development.








Our Jacketed Glass Reactor features a dual-layered vessel that allows a controlled fluid to circulate through the outer jacket, creating a stable thermal environment. This setup enables efficient heat exchange, making it adaptable to both heating and cooling demands. The circulating liquid evenly distributes temperature around the reaction chamber, preventing hotspots that could compromise experiment integrity. This method supports sensitive processes requiring gradual temperature shifts and ensures consistent reaction conditions. The jacketed design also protects the inner vessel from thermal shock by moderating rapid temperature changes. This capability expands its use across diverse laboratory applications where temperature precision is vital. The system’s adaptability ensures researchers can work within a broad thermal range safely and effectively.
The vacuum capability in this jacketed glass reactor is supported by a robust double-sealing mechanism combining PTFE and fluororubber materials, ensuring airtight containment. This design prevents atmospheric gases from entering, which could interfere with reaction purity and cause contamination. Maintaining a stable vacuum environment is crucial for processes like distillation and solvent removal, where reduced pressure lowers boiling points and protects sensitive compounds. The reactor’s structure also resists degradation from repeated vacuum cycles, maintaining long-term performance. This dependable vacuum seal enhances process control by allowing precise pressure adjustments throughout experiments. Researchers benefit from a consistent low-pressure environment that supports sensitive chemical and pharmaceutical applications. The vacuum system’s strength contributes directly to the reactor’s versatility in handling a wide range of laboratory tasks.
Labtron’s jacketed glass reactor uses high-quality borosilicate glass known for its ability to withstand thermal fluctuations and resist chemical corrosion. This material choice means the reactor can endure aggressive solvents and prolonged heating without compromising structural integrity. The cylindrical shape distributes stress evenly, reducing the risk of breakage during operation. Combined with the secure lid and sealing system, the vessel maintains its stability even under vacuum or pressurized conditions. The reactor’s design also simplifies inspection and cleaning, helping maintain safe usage over time. This durability reduces the need for frequent replacements, making it a cost-effective solution for repeated experimental cycles. Users can trust the reactor to hold up in demanding environments such as chemical synthesis and bio-pharmaceutical development. The robustness of the materials and design ensures longevity in the laboratory.
The external loop buffer provides a secure and stable interface between the reactor’s jacket and the circulating fluid lines. This fixed connection prevents stress or strain on the glass joints that could result from vibration or movement during operation. It ensures that fluid flow remains uninterrupted and consistent, which is essential for maintaining the desired temperature in the jacket. By minimizing mechanical wear on the connections, the buffer extends the lifespan of the reactor’s sealing system. This feature also facilitates easier setup and disassembly, improving overall workflow efficiency. The stable connection helps prevent leaks and accidental disconnections that might compromise experiments or safety. This design consideration improves the reactor’s reliability during prolonged usage in demanding research settings. The external loop buffer is a critical component that supports continuous and safe operation.
The jacketed glass reactor’s wide lid provides ample access to the vessel’s interior, simplifying material addition, sampling, and cleaning processes. This ease of access reduces preparation time between experiments and supports efficient workflow in busy laboratory environments. The lid’s design also accommodates various attachments such as condensers, sensors, and dropping funnels, enhancing the reactor’s versatility. Secure sealing mechanisms on the lid ensure airtight conditions are maintained, even during vacuum or pressure operations. This feature minimizes the risk of contamination and evaporation losses, protecting experiment integrity. The wide opening also allows for better visual monitoring during reactions, aiding in process control and adjustments. Together, these advantages make the reactor user-friendly and adaptable to a broad range of laboratory tasks. The lid’s thoughtful design contributes significantly to operational convenience.
The stirring system integrated into the jacketed glass reactor enables controlled agitation of the reaction mixture, promoting uniform distribution of heat and reactants. Adjustable stirring speeds accommodate a variety of viscosities, from thin liquids to thicker suspensions, ensuring efficient mixing. This uniform agitation prevents sedimentation and local concentration gradients, which can otherwise lead to inconsistent reaction results. The stirring mechanism operates smoothly to avoid introducing vibrations or stresses that could damage the glass vessel. It supports continuous operation over long periods, making it suitable for reactions that require extended processing times. Effective stirring enhances reaction kinetics by improving contact between reactants and facilitating heat transfer. This contributes to reproducibility and scalability, important factors in both research and pilot production settings. The stirring capability is therefore integral to achieving reliable and consistent experiment results.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom