Request A Quote
Jacketed Glass Reactor LJGR-B15

Jacketed Glass Reactor LJGR-B15

Jacketed Glass Reactor LJGR-B15 features a 30 L vessel that supports high-volume synthesis and thermal processing across research workflows. The dual-layer jacket maintains consistent internal temperatures by circulating heating or cooling fluids. Its solid charging port allows quick addition of material batches without interrupting ongoing reactions. Our reactor is used in pharmaceutical extraction, pilot-scale distillation, and petroleum compound development.

Request Quote
Glass Vessel Volume 30 L Cylindrical
Dropping Funnel Volume 2000 mL
Dropping Funnel Interface 40/38
Glass Vessel Flange Φ 215 mm
Glass Vessel Opening OD Φ 265 mm
Glass Material 3.3 Borosilicate
Bottom Valve ID Φ 21 mm
Jacket Interface 35 mm
Jacket Interface Pressure Limit Less than or equal to 0.03 Mpa
Circulation Hose Connection Port Rc3/4
Glass Vessel Lid Openings 6
Center Opening of Lid 50 mm
Side Opening of Lid 34/35, 35 mm, 40/38, S51, S51
Seal Ring on Vessel Lid Φ264×Φ220×3
Drain Port Ground Clearence 360 mm
Stirring Speed 50 to 500 rpm
Support Parts for Stirrer PTFE
Condenser Interface 40/38
Condenser Area 0.234 m2
Solid Charging Port 80 mm
Liquid Collection Tray Optional
Receiving Bottle Optional
Power Consumption 180 W
Dimensions (W×D×H) 825×720×2090 mm
  • Quick release fastening joints

  • Stable multi-point grounding base

  • Extended neck coupling ports

  • Spill-controlled transfer zone

  • Vertical condenser mounting slot

Jacketed Glass Reactor LJGR-B15 supports thermal regulation for synthesis, distillation, and crystallization processes. This ensures stable reaction conditions for compound extraction, solvent recovery, and temperature-sensitive applications.

Models of Jacketed Glass Reactor

Jacketed Glass Reactor supports controlled mixing with adjustable stirring speed, ensuring consistent reaction dynamics in varied experiments. They maintain thermal stability using a jacketed layer for fluid circulation without exposing the medium. Their borosilicate glass build withstands thermal stress and chemical exposure over time. These systems include a display panel for monitoring key parameters during operation. Our glass reactor is suited for synthesis, distillation, extraction, crystallization, and pharmaceutical development.

Jacketed Glass Reactor LJGR-A40

Jacketed Glass Reactor LJGR-A40

  • Glass Vessel Volume : 100 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 340 mm
  • Jacketed Volume : 25000 ml
  • Dropping Funnel : 50 ml
Jacketed Glass Reactor LJGR-A10

Jacketed Glass Reactor LJGR-A10

  • Glass Vessel Volume : 1 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 150 mm
  • Jacketed Volume : 200 ml
  • Display : Stirring Speed, Timer, Temperature
Jacketed Glass Reactor LJGR-A46

Jacketed Glass Reactor LJGR-A46

  • Glass Vessel Volume : 1 L Cylindrical
  • Dropping Funnel Volume : 200 ml
  • Dropping Funnel Interface : 24/29
  • Glass Vessel Flange : Φ 105 mm
Jacketed Glass Reactor LJGR-A50
Jacketed Glass Reactor LJGR-A50
  • Glass Vessel Volume : 5 L (Cylindrical)
  • Jacket Volume : 1.5 L
  • Glass Vessel Flange : Φ 170 mm
  • Glass Vessel Opening OD : Φ 215 mm
Jacketed Glass Reactor LJGR-A32
Jacketed Glass Reactor LJGR-A32
  • Glass Vessel Volume : 50 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 265 mm
  • Jacketed Volume : 7000 ml
  • Dropping Funnel : 1000 ml
Jacketed Glass Reactor LJGR-A35

Jacketed Glass Reactor LJGR-A35

  • Glass Vessel Volume : 200 L Cylindrical
  • Receiving Bottle : 10 L
  • Glass Vessel Lid Diameter : Φ 340 mm
  • Jacketed Volume : 40000 ml
Jacketed Glass Reactor LJGR-A16

Jacketed Glass Reactor LJGR-A16

  • Glass Vessel Volume : 3 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 205 mm
  • Jacketed Volume : 600 ml
  • Dropping Funnel : 500 ml
Jacketed Glass Reactor LJGR-A14

Jacketed Glass Reactor LJGR-A14

  • Glass Vessel Volume : 1 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 150 mm
  • Jacketed Volume : 200 ml
  • Dropping Funnel : 250 ml

Jacketed Glass Reactor LJGR-B15 FAQ's
  • Our Jacketed Glass Reactor LJGR-B15 operates effectively with or without the collection tray, as it’s not structurally dependent on it. Customers who don't require drip recovery during transfers can choose to omit it entirely. The base design ensures stability and cleanliness even without the tray attached. This flexibility helps in minimizing space or cleaning requirements for certain protocols. Its drain port remains fully functional regardless of tray inclusion. For users who prioritize compact setups or specific waste disposal methods, the omission presents no compromise. That way, labs can scale features based on actual workflow rather than default configurations.

  • The Jacketed Glass Reactor LJGR-B15 includes insulated hose connections to reduce thermal shock, but customers often ask if full vessel insulation is necessary. While the built-in design slows down ambient heat gain, very low temperature applications may benefit from added external wraps. This is especially useful when sub-zero circulators are running for extended durations. However, the reactor can function without extra insulation in moderate cooling processes. The borosilicate body handles thermal contraction well without cracking risks. Whether or not to insulate externally depends on cooling intensity and lab temperature. Our design provides the choice without forcing additional equipment purchases.

  • The Jacketed Glass Reactor LJGR-B15 is often chosen by customers who prefer minimal disassembly during cleaning cycles. Its open-top structure and multiple access ports allow users to rinse and clean the interior efficiently without removing the vessel from the frame. For many compounds, a basic flush with compatible solvents is enough to clear residues. The reactor also supports the use of internal cleaning brushes if required. This is particularly helpful in multi-run labs that cannot afford extended downtimes. Customers appreciate that cleanup doesn't require tool-assisted disassembly. It saves time and prevents misalignment or stress on glass fittings.

  • The Jacketed Glass Reactor LJGR-B15 includes buffered hose interfaces that absorb stress when attaching or detaching circulation lines. Still, buyers sometimes worry about hairline cracks from repeated use. Our design includes insulated connection ports that reduce direct mechanical pressure on the glass jacket. The hose fittings are positioned to guide movement away from fragile points. This lowers the risk of sideward torque during setup or disconnection. Operators do not need to support the jacket manually while attaching hoses. That structural support is built in. Over time, this design choice significantly reduces accidental fractures from daily handling.

  • Labtron’s Jacketed Glass Reactor LJGR-B15 is frequently used in reactions involving viscous or particle-laden fluids, and customers often ask whether the stirring system remains stable under load. The unit’s motor and stirring support can handle moderate resistance without slippage or jamming. Its coupling prevents direct stress on the vessel’s central shaft. This means even gel-forming reactions or heavy slurry preparations don’t disturb uniform mixing. The stirring mechanism is engineered to hold torque without sudden shifts in direction. This reduces mechanical wear and protects the batch contents from inconsistent agitation. For demanding mixtures, this consistent control is essential.

  • The Jacketed Glass Reactor LJGR-B15 is often installed in shared research labs, and customers frequently ask whether it's suitable for multi-user handling. Its build supports daily setup and reconfiguration by different users without degrading key components. The controls, ports, and vessel orientation are clearly marked to avoid confusion or misuse. Cleaning between users is simple, with easy drain access and open-top visibility. The structure also minimizes accidental tampering, which is crucial in academic and rotational research spaces. Our design helps labs maintain a safe, modular workflow. That reliability makes it a solid choice for rotating team environments.

Post your question?

Our experts are here to help!

Jacketed Glass Reactor:
Jacketed Glass Reactor LJGR-A40, Jacketed Glass Reactor LJGR-A10, Jacketed Glass Reactor LJGR-A46, Jacketed Glass Reactor LJGR-A50, Jacketed Glass Reactor LJGR-A32, Jacketed Glass Reactor LJGR-A35, Jacketed Glass Reactor LJGR-A16, Jacketed Glass Reactor LJGR-A14, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.