Folding endurance tester TP-M10 is used to measure the folding endurance of paper, cardboard and other paper like sheet, material. The folding clamp can be positioned automatically. The microprocessor controlled technology, complete functions, stable performance, easy to use parameters are the advantages of this instrument.

Request Quote
Measuring scope 0 to 99999 s
Folding angle 135° ± 2°
Tensile scope 4.9 to 14.7 N
Folding head suture size 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Folding radius 0.38 ± 0.02 mm
Dimension (L×W×H) 320×320×450 mm
Net weight 35 kg
Power supply AC220 V ± 10 % , 50 Hz
  • Touch screen display
  • Automatic measurements, statistic values
  • Automatic return to zero once the test gets completed
  • Can print the test results
  • Data storage function
  • Electromechanical integration of modern design
  • Easy operations, safe & reliable results

Folding endurance tester has applications in paper industry, cardboard, packaging industry.

Compare Models

Model Measurement range Measuring scope Folding angle Tensile scope Folding head suture size Folding radius Resolution Accuracy Variability Speed Vacuum system volume (ml) Contact pressure Vacuum scope Air volume (50.66 kPa down to 48.00 kPa) Maximum distance Compression speed Clamp pressure Diameter of upper clamp Diameter of lower clamp Pneumatic pressure Film resistance Dimension (L×W×H) Net weight Power supply
TP-A10 - - - - - - - Chromaticity co-ordinate 0.0001 - - - - - - - - - - - - - - 23 kg 220 V ± 10 %, 50 Hz
TP-A11 - - - - - - - - - - - - - - - - - - - - - - 20 kg 220 V ± 10 %, 50 Hz
TP-B10 - - - - - - - - - - - - - - - - - - - - - - 15 kg 220 V ± 10 %, 50 Hz
TP-B11 - - - - - - - ± 1 % - - - - - - - - - - - - - - 65 kg 220 V ± 10 %, 50 Hz
TP-B12 - - - - - - - ± 1 % - - - - - - - - - - - - - - 40 kg 220 V ± 10 %, 50 Hz
TP-B20 - - - - - - - ± 1 % - - - - - - - - - - - - - - 55 kg 220 V ± 10 %, 50 Hz
TP-C10 0 to 100° SR - - - - - - - - - - - - - - - - - - - - - - -
TP-C20 0 to 200 mm - - - - - - - - - - - - - - - - - - - - - - -
TP-C21 - - - - - - - - - - - - - - - - - - - - - - - -
TP-C30 - - - - - - - - - - - - - - - - - - - - - - - -
TP-D10 0.01 to 10 N - - - - - - - - - - - - - - - - - - - - - - -
TP-E10 - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-E20 - - - - - - - 0.01 or 0.001 mm - - - - - - - - - - - - - - - -
TP-E21 - - - - - - - 0.01 mm - - - - - - - - - - - - - - - -
TP-F10 - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-G10 - - - - - - - - - - - - - - - - - - - - - - - -
TP-H10 - - - - - - - ± 1% - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-I10 - - - - - - - - - - - - - - - 10 mm/ min - - - - - - - AC220 V ± 10 % , 50 Hz
TP-I11 - - - - - - - - - - - - - - - 10 mm/ min - - - - - - - AC220 V ± 10 % , 50 Hz
TP-J10 - - - - - - - - - - - - - - - - - - - - - - - -
TP-J11 - - - - - - - - - - - - - - - - - - - - - - - -
TP-J12 - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-J20 - - - - - - 0.1 mN - - - - - - - - - - - - - - - - -
TP-J21 - - - - - - 0.1 mN - - - - - - - - - - - - - - - - -
TP-K10 0 to 5600 kPa - - - - - - ± 0.5 % F.S. - - - - - - - 170 ± 15 ml/min ≥ 690 kPa 31.5 ± 0.05 mm 31.5 ± 0.05 mm 0.45 to 0.6 MPa For bulge height = 10 mm, The pressure = 170 to 220 kPa
For bulge height = 18 mm, The pressure = 250 to 350 kPa
480×420×600 mm 65 kg AC220 V ± 10 % , 50 Hz
TP-K11 50 to 1600 kPa-paper and 50 to 5600 kPa-paper - - - - - 0.01 kPa ≤± 0.5 % - - - - - - - 95 ± 5 ml/min 400 kPa to 1200 kPa(adjustable) 30.5 ± 0.1 mm 33.1 ± 0.1 mm 0.3 to 0.5 MPa (9±0.2)mm/(30±5)kPa 428×318×412 mm 50 kg AC220 V ± 10 % , 50 Hz
TP-L10 5 to 500 N, 50 to 3000 N - - - - - 1 N ± 1 % ≤ 1 % 12.5 ± 2.5 mm/min - - - - 78 mm - - - - - - 450×400×500 mm 75 kg AC220 V ± 10 % , 50 Hz
TP-L20 - ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s) - - - - - ±0.1 s within 300 s - - Bigger volume: 380 ± 1
Smaller volume: 38 ± 1
100 ± 2 kPa I) 50.66 to 48.00
II) 50.66 to 48.00
III) 50.66 to 29.33
Automatic: No limit
Big vacuum volume: 10.00 ± 0.20 ml
Small vacuum volume: 1.00 ± 0.05 ml
- - - - - - - 325×390×430 mm 30 kg AC220 V ± 10 % , 50 Hz
TP-M10 - 0 to 99999 s 135° ± 2° 4.9 to 14.7 N 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm 0.38 ± 0.02 mm - - - - - - - - - - - - - - - 320×320×450 mm 35 kg AC220 V ± 10 % , 50 Hz
TP-E30 - - - - - - - - - - - - - - - - - - - - - - - -