Tabletop Autoclave LTTA-H15 has a size of Ø200 × 355 mm for sterilizing small to medium-sized instruments. It features an audible cycle completion alert for convenience. The instant steam generation technology accelerates the sterilization process. Its premium inner chamber finish supports long-lasting performance and easy maintenance. Our tabletop autoclave has programmable sterilization settings that provide flexible control.

Tabletop Autoclave LTTA-H15
Tabletop Autoclave LTTA-H15
Tabletop Autoclave LTTA-H15
Tabletop Autoclave LTTA-H15
Tabletop Autoclave LTTA-H15
Request Quote
Capacity 12 L
Chamber Size Ø200 × 355 mm
Working Sterilization Temperature 134℃
Working Sterilization Pressure 0.22 Mpa
Design Pressure 0.25 Mpa (2.5 bar)
Design Temperature 139℃
Working Pressure 0.22 Mpa (2.2 bar)
Voltage 110 V/220 V,60 Hz/50 Hz
Power Consumption 2 kW
Outer Dimension (L × W × H) 445 × 580 × 400 mm
Packing Dimension (L × W × H) 650 × 500 × 450 mm
Gross Weight 48 kg
Net Weight 44 kg
  • Intelligent Locking Mechanism

  • External Device Compatibility Port

  • Convenient Water Tank Access

  • Overheat Prevention System

  • Cycle Completion Sound Alert

Tabletop Autoclave LTTA-H15 is a compact sterilization unit that uses pressurized steam to disinfect medical and laboratory tools efficiently. It is widely used in clinics, dental offices, and research labs for quick and reliable sterilization of small instruments and glassware.

Models of Table Top Autoclave

Labtron Table Top Autoclave offer compact sterilizer of 18 L to 50 L that fits easily on workstation. Their effective sterilization is achieved through steam under pressure of 0.22 Mpa. They feature over-temperature monitoring and multiple evaporator controls for enhanced safety. Their quick cycle times significantly enhance workflow efficiency, reducing downtime between procedures. Our Table Top Autoclave is ideal for modest scale sterilization in medical, dental and research labs.

Tabletop Autoclave LTTA-A13

Tabletop Autoclave LTTA-A13

  • Capacity : 50 L
  • Maximum Working Pressure : 0.23 MPa
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
Tabletop Autoclave LTTA-A12

Tabletop Autoclave LTTA-A12

  • Capacity : 35 L
  • Maximum Working Pressure : 0.23 MPa
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
Tabletop Autoclave LTTA-J11

Tabletop Autoclave LTTA-J11

  • Capacity : 24L
  • Maximum Working Pressure : 0.22 MPa
  • Maximum Working Temperature : 134°C
  • Temperature Adjust Range : 105 to 134°C
Tabletop Autoclave LTTA-G21
Tabletop Autoclave LTTA-G21
  • Capacity : 35 L
  • Working temperature : 134 ºC
  • Adjustment of temperature : 105 to 134 ºC
  • Working pressure : 0.22 Mpa
Tabletop Autoclave LTTA-F20
Tabletop Autoclave LTTA-F20
  • Chamber Volume : 23 L
  • Chamber Size : Ø250 × 452 mm
  • Working Temperature : 134℃
  • Working Pressure : 0.22 MPa
Tabletop Autoclave LTTA-H16

Tabletop Autoclave LTTA-H16

  • Capacity : 18 L
  • Chamber Size : Ø250 × 370 mm
  • Working Sterilization Temperature : 134℃
  • Working Sterilization Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-H10

Tabletop Autoclave LTTA-H10

  • Capacity : 8 L
  • Chamber Size : Ø170 × 320 mm
  • Working Sterilization Temperature : 134℃
  • Working Sterilization Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-H12

Tabletop Autoclave LTTA-H12

  • Capacity : 18 L
  • Chamber Size : Ø250 × 370 mm
  • Working Sterilization Temperature : 134℃
  • Working Sterilization Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-H15 FAQ's
  • Labtron tabletop autoclaves offer a variety of cycle times depending on the type of load, selected temperature, and drying time. A standard sterilization cycle at 121°C might take 20–30 minutes, while a cycle at 134°C (commonly used for surgical tools) can be completed in 15–25 minutes. When including pre-vacuum and drying phases, the total time may range from 45 to 90 minutes, depending on load size and moisture content. Labtron units display real-time progress and countdown timers on a digital control panel, allowing users to monitor the process. Some advanced models also feature express or rapid cycles for unwrapped instruments or emergency situations, completing the cycle in under 30 minutes while still maintaining sterilization effectiveness.

  • Labtron offers both Class B and Class N tabletop autoclaves, each designed for different sterilization needs. Class B autoclaves use a pre-vacuum process to remove air from the chamber before introducing steam, making them ideal for hollow instruments, wrapped items, textiles, and other porous materials. They are compliant with EN 13060 standards and are suitable for medical, dental, and surgical applications requiring strict sterilization protocols. Class N autoclaves, on the other hand, use gravity displacement and are best for unwrapped solid instruments and simpler applications. Labtron helps users choose the right class based on load types, sterilization frequency, and regulatory requirements, ensuring users have an autoclave that aligns with their specific practice or facility needs.

  • Labtron tabletop autoclaves are compact, portable, and designed to be easily relocated, making them ideal for mobile clinics, field laboratories, disaster relief units, and remote research stations. These units feature rugged construction, integrated water reservoirs, and automated control systems, reducing the need for constant operator intervention. They only require a stable power source and a safe, flat surface to operate. Some models even come with carry handles and shock-resistant enclosures, allowing them to withstand the rigors of transportation. Labtron's design emphasis on reliability and ease of use ensures that healthcare professionals and researchers can maintain sterile environments even in challenging or off-grid locations.

  • Labtron tabletop autoclaves are advanced sterilization devices that differ significantly from basic pressure cookers or non-regulated sterilizers in both functionality and safety standards. Unlike domestic or improvised sterilizers, Labtron autoclaves feature programmable electronic control systems that allow precise adjustments of cycle time, temperature, and pressure based on load type. They are built to comply with international sterilization guidelines such as EN 13060, ISO 13485, and CE standards, making them suitable for professional healthcare and laboratory applications. Additionally, Labtron tabletop autoclaves come with integrated safety features like automatic pressure locks, error alarms, cycle documentation, and fail-safes that prevent operation if conditions are not optimal.Labtron units can generate sterilization logs, cycle history, and printed records, which are critical for quality assurance, auditing, and regulatory compliance.

  • Labtron tabletop autoclaves are equipped with digital logging systems that help users track and record each sterilization cycle, which is critical for regulatory compliance and internal quality audits. Many models include USB ports, SD card slots, or built-in printers that generate detailed cycle reports containing time, temperature, pressure data, and cycle validation status. These reports can be saved, printed, or uploaded to hospital/lab information systems for review. Some advanced units also support barcode scanning and batch tracking, ensuring each sterilization load is fully documented and traceable. This feature is especially valuable in clinical and research environments where instrument sterilization logs must be maintained for patient safety and institutional audits.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.