Tabletop Autoclave LTTA-I11 has a capacity of 60L, providing ample space for sterilizing a variety of instruments and materials in a single cycle. It operates within a temperature range of 105°C to 138°C, allowing effective sterilization. The autoclave has a horizontal cylindrical design with three layers chamber, jacket, and insulation. A built-in high-quality vacuum pump ensures complete air removal for optimal steam sterilization. The chamber and door of our tabletop autoclave made of durable AISI 304 stainless steel, while the steam generator and pipes use stainless steel 304 for strength and hygiene.

Table Top Autoclave LTTA-I11
Table Top Autoclave LTTA-I11
Table Top Autoclave LTTA-I11
Request Quote
Capacity 60L
Working Temperature 105 to 138°C
Working Pressure 0 to 0.25 Mpa
Design Pressure -0.1 / 0.3 Mpa
Chamber Size Ø386 × 520 mm
Sterilization Programs Preset cycle: Textile, Solid, Liquid, Rubber, Instrument, Glassware
User-defined cycle: 5 cycles
Test cycle: B-D test, Vacuum test
Sterilization Time 0 to 99 min
Drying Time 0 to 99 min
Vacuum Rate -0.09 Mpa
Temperature Accuracy ±0.1°C
Heat Average Less than equal to 1°C
Vacuum System Yes, pre-vacuum and post-vacuum
Control Microprocessor
Display 3.2-inch LCD screen
Steam Generator Built-in, stainless steel 304
Chamber Material Stainless steel AISI 304
Water Tank Built-in
Door Safety interlock door
Drying Function Vacuum drying
Printer Built-in printer
Loading Sterilization tray and rack
Voltage 220V ±10%, 50/60Hz
Power 6.6 KW
Product Dimensions 980 × 730 × 680 mm
Packaging Dimensions 1080 × 830 × 880 mm
Net Weight 160 Kg
Gross Weight 200 Kg
  • Fully automatic microcomputer control

  • 3.2-inch LCD screen

  • Automatic safety interlock

  • Water level sensor

  • Fault detection system

  • Built-in open water tank

  • Hydrophobic system

  • Built-in printer

  • Safety protection device

  • Audible and visual alarms

Tabletop Autoclave LTTA-I11 is used across labs, CSSDs, research, pharma, and food industries to sterilize heat- and pressure-resistant items like instruments, dressings, rubber, liquids, and porous or hollow tools.

Table Top Autoclave LTTA-I11 | Volume: 60L| Working Temperature: 105 to 138°C
Table Top Autoclave LTTA-I11 | Water level sensor | Fault detection system

Models of Table Top Autoclave

Labtron Table Top Autoclave offer compact sterilizer of 18 L to 50 L that fits easily on workstation. Their effective sterilization is achieved through steam under pressure of 0.22 Mpa. They feature over-temperature monitoring and multiple evaporator controls for enhanced safety. Their quick cycle times significantly enhance workflow efficiency, reducing downtime between procedures. Our Table Top Autoclave is ideal for modest scale sterilization in medical, dental and research labs.

Tabletop Autoclave LTTA-H13

Tabletop Autoclave LTTA-H13

  • Capacity : 23 L
  • Chamber Size : Ø250 × 452 mm
  • Working Sterilization Temperature : 134℃
  • Working Sterilization Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-B12

Tabletop Autoclave LTTA-B12

  • Capacity : 35 L
  • Maximum Working Pressure : 0.23 MPa
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
Tabletop Autoclave LTTA-E14

Tabletop Autoclave LTTA-E14

  • Capacity : 50 L
  • Sterilization Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
  • Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-G10
Tabletop Autoclave LTTA-G10
  • Capacity : 18L
  • Chamber Size : Ø250×370
  • Temperature Range : 121°C and 134°C
  • Sterilization Temperature : 134℃
Tabletop Autoclave LTTA-G21
Tabletop Autoclave LTTA-G21
  • Capacity : 35 L
  • Working temperature : 134 ºC
  • Adjustment of temperature : 105 to 134 ºC
  • Working pressure : 0.22 Mpa
Table Top Autoclave LTTA-L10

Table Top Autoclave LTTA-L10

  • Capacity : 18L
  • Display : LED Screen
  • Control System : Microprocessor Controlled
  • Display Type : Digital Display
Tabletop Autoclave LTTA-F20

Tabletop Autoclave LTTA-F20

  • Capacity : 18L
  • Chamber Size : Ø250 × 370 mm
  • Rated Working Temperature : 134℃
  • Temp. Accuracy : ±1℃
Tabletop Autoclave LTTA-H14

Tabletop Autoclave LTTA-H14

  • Capacity : 8 L
  • Chamber Size : Ø170 × 320 mm
  • Working Sterilization Temperature : 134℃
  • Working Sterilization Pressure : 0.22 Mpa

Tabletop Autoclave LTTA-I11 FAQ's
  • The vacuum system plays a key role in effective sterilization. In many Labtron autoclaves, a high-quality vacuum pump is used to remove air from the chamber before the steam is introduced. This pre-vacuum process ensures there are no air pockets that could block the steam from reaching every surface of the items inside. Some models also perform post-vacuum drying, which helps remove residual moisture and speeds up the drying process. This makes the sterilization more thorough and efficient, especially for wrapped or porous loads.

  • Labtron tabletop autoclaves are built with multiple safety features to ensure safe operation. These include an automatic safety interlock system that prevents the door from opening when the chamber is pressurized. They also have sensors to monitor water levels and detect faults in the system. Audible and visual alarms alert the user if something goes wrong during the cycle. Additionally, the autoclaves are designed with built-in protections against overheating or pressure build-up, giving users peace of mind while operating the equipment.

  • Microprocessor control allows for precise management of the sterilization cycle. It ensures that the correct temperature, pressure, and timing are maintained throughout the process. This helps achieve consistent and reliable sterilization results every time. Labtron autoclaves with microprocessor control also allow users to select from preset programs or create their own sterilization cycles based on specific needs. Combined with features like an LCD display, it makes operation easy, user-friendly, and more efficient.

  • A tabletop autoclave is a compact sterilization device designed to fit on a lab bench or table. It works by using high-pressure steam to kill bacteria, viruses, fungi, and spores on instruments and materials. The steam is produced inside the unit and fills the chamber where items are placed. Most modern tabletop autoclaves include vacuum systems to remove air before sterilization, ensuring the steam penetrates every surface. After sterilization, a drying cycle removes moisture, making the items ready for safe use or storage.

  • Labtron tabletop autoclaves are designed to sterilize a wide range of heat- and pressure-resistant materials. These include surgical instruments, glassware, dressings, rubber items, and even liquids. They are also suitable for sterilizing porous and hollow items such as pipette tips, dental tools, and wrapped instruments. However, it’s important to ensure that materials are compatible with steam sterilization and follow the manufacturer’s recommendations to avoid damage.

Post your question?

Our experts are here to help!

Table Top Autoclave:
Tabletop Autoclave LTTA-H13, Tabletop Autoclave LTTA-B12, Tabletop Autoclave LTTA-E14, Tabletop Autoclave LTTA-G10, Tabletop Autoclave LTTA-G21, Table Top Autoclave LTTA-L10, Tabletop Autoclave LTTA-F20, Tabletop Autoclave LTTA-H14, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.