Tabletop Autoclave LTTA-H10

Tabletop Autoclave LTTA-H10

Tabletop Autoclave LTTA-H10 has a capacity of 8 L for a small laboratory requiring efficient sterilization. The durable, sealed chamber design ensures long-lasting use and prevents external contamination. Its customizable temperature settings allow users to tailor sterilization cycles based on specific needs. The smart sterilization cycle control provides precision in temperature regulation for effective decontamination. Our tabletop autoclave has an integrated diagnostic port that enables easy system monitoring.

Tabletop Autoclave LTTA-H10
Tabletop Autoclave LTTA-H10
Request Quote
Capacity 8 L
Chamber Size Ø170 × 320 mm
Working Sterilization Temperature 134℃
Working Sterilization Pressure 0.22 Mpa
Design Pressure 0.25 Mpa (2.5 bar)
Design Temperature 139℃
Working Pressure 0.22 Mpa (2.2 bar)
Voltage 110 V/220 V,60 Hz/50 Hz
Power Consumption 1.5 kW
Outer Dimension (L × W × H) 445 × 580 × 400 mm
Packing Dimension (L × W × H) 650 × 500 × 450 mm
Gross Weight 45 kg
Net Weight 42 kg
  • Microcomputer Controlled Sterilization

  • Advanced Safety Interlock System

  • User-Friendly Touch Controls

  • Standard Test Interface Equipped

  • Top-Fill Water Tank

Tabletop Autoclave LTTA-H10 is a compact sterilization unit that uses pressurized steam to disinfect medical and laboratory tools efficiently. It is widely used in clinics, dental offices, and research labs for quick and reliable sterilization of small instruments and glassware.

Models of Table Top Autoclave

Labtron Table Top Autoclave offer compact sterilizer of 18 L to 50 L that fits easily on workstation. Their effective sterilization is achieved through steam under pressure of 0.22 Mpa. They feature over-temperature monitoring and multiple evaporator controls for enhanced safety. Their quick cycle times significantly enhance workflow efficiency, reducing downtime between procedures. Our Table Top Autoclave is ideal for modest scale sterilization in medical, dental and research labs.

Tabletop Autoclave LTTA-H13

Tabletop Autoclave LTTA-H13

  • Capacity : 23 L
  • Chamber Size : Ø250 × 452 mm
  • Working Sterilization Temperature : 134℃
  • Working Sterilization Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-A12

Tabletop Autoclave LTTA-A12

  • Capacity : 35 L
  • Maximum Working Pressure : 0.23 MPa
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
Tabletop Autoclave LTTA-A10

Tabletop Autoclave LTTA-A10

  • Capacity : 20 L
  • Sterilization Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
  • Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-H14
Tabletop Autoclave LTTA-H14
  • Capacity : 23 L
  • Chamber Size : Φ 250 x 452 mm
  • Maximum Working Temperature : 134℃
  • Maximum Working Pressure : 0.22 MPa
Tabletop Autoclave LTTA-D10
Tabletop Autoclave LTTA-D10
  • Capacity : 20 L
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
  • Temperature Range : 105 to 134°C
Table Top Autoclave LTTA-G20

Table Top Autoclave LTTA-G20

  • Capacity : 50 L
  • Chamber Size : Φ 340 x 550 mm
  • Maximum Working Temperature : 134℃
  • Maximum Working Pressure : 0.22 MPa
Tabletop Autoclave LTTA-B12

Tabletop Autoclave LTTA-B12

  • Capacity : 35 L
  • Maximum Working Pressure : 0.23 MPa
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
Tabletop Autoclave LTTA-A13

Tabletop Autoclave LTTA-A13

  • Capacity : 50 L
  • Maximum Working Pressure : 0.23 MPa
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
Tabletop Autoclave LTTA-H10 FAQ's
  • Labtron tabletop autoclaves are primarily designed for low to medium-capacity sterilization needs, unlike vertical or horizontal autoclaves which are often used for high-volume or industrial applications. While the underlying principle of steam sterilization remains the same, tabletop models are more portable, energy-efficient, and space-saving. They are typically placed on benchtops, require less installation effort, and are ideal for routine use. They also consume less water and power, making them a more cost-effective solution for smaller laboratories or clinics that don’t require bulk sterilization.

  • Labtron tabletop autoclaves are equipped with pre-vacuum and drying phases, allowing them to effectively sterilize wrapped or packaged instruments, which is essential for maintaining sterility until the items are used. These features help remove air pockets from both the chamber and the packaging, ensuring even steam penetration. The drying cycle uses residual chamber heat and vacuum to eliminate moisture, which prevents the re-growth of microorganisms. This makes them suitable for dental tools, surgical instruments, reusable lab kits, and any item that needs to be stored sterile for later use.

  • Labtron designs its tabletop autoclaves to be highly user-friendly, even for non-technical staff. They feature touchscreen digital displays or button-operated panels, with pre-programmed cycles for different types of loads (e.g., solids, liquids, wrapped instruments). Most models include automated functions like water filling, steam generation, pressure release, and drying, which minimize manual intervention and reduce error. Users are guided through each step of the sterilization process with visual and audio cues, and error messages are clearly displayed for troubleshooting. This ease of operation increases efficiency and helps maintain consistent sterilization standards across all users.

  • Labtron tabletop autoclaves are engineered for low-maintenance operation, but regular care is crucial to ensure consistent performance and long service life. Routine maintenance includes checking the water reservoir, cleaning the chamber, inspecting door gaskets, descaling the heating elements, and ensuring the drainage system is clear. The control system usually provides service reminders or alerts for maintenance intervals. Labtron also provides a detailed user manual and preventive maintenance schedule, making upkeep simple even for first-time users.

  • Labtron designs its tabletop autoclaves to be highly efficient in both water and power consumption. Modern models use microprocessor-based systems to optimize steam generation and regulate energy usage, reducing operational costs over time. The autoclaves are also equipped with automatic water usage control and shut-off features, preventing wastage and ensuring safe operation. These efficiency features make them ideal for facilities looking to reduce their ecological footprint without compromising sterilization quality.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.