Vertical Autoclave LVA-E21 is built with a SUS304-grade stainless steel chamber. It is a high-performance, fully automatic unit designed to meet the sterilization needs of modern laboratories and healthcare facilities. A robust heating system enables faster sterilization cycles without compromising safety. Ideal for environments that demand strict hygiene and high sterilization standards. Our autoclave ensures efficient and consistent sterilization of instruments, liquids, glassware, and other lab tools.

Vertical Autoclave LVA-E21
Request Quote
Volume of Chamber 40 L
Chamber thickness 2 mm
Working temperature 50 °C to 134 °C
Working pressure 0.217 MPa
Working environment 5 °C to 45°C
Relative humidity 10% to 85%
Time setting range 0 to 99h
Rated power 3500W
Power supply 220V, 50/60Hz
Dimension 570 × 690 × 1020 mm
Net weight 94 Kg
Gross weight 97 Kg
  • Smart Self-Diagnosis Function

  • Cycle Memory Recall

  • Pre-set Sterilization Programs

  • Built-in Water Level Sensor

  • Insulated Outer Casing

Our autoclave is used for sterilizing equipment and materials across scientific research, healthcare, pharmaceuticals, food safety, veterinary care, education, and industrial testing, ensuring contamination control and maintaining sterile conditions efficiently.

Vertical Autoclave LVA-E21 | Volume: 40 L | Chamber Thickness: 2 mmm
Vertical Autoclave LVA-E21 | Smart Self-Diagnosis Function | Cycle Memory Recall


Models of Vertical Autoclave

Labtron Vertical Autoclave provide upright design, high pressure steam sterilizer at working temperature of 134℃. Their orientation makes loading and unloading more convenient and efficient. They feature sensors and automatic shut off system enhancing safety by preventing overeating during operation. Their programmable controls enable automatic operation, managing heating, sterilization and cooling phases efficiently. Our Vertical Autoclave effectively eliminates pathogens from glassware and media, ensuring infection control in healthcare settings.

Vertical Autoclave LVA-L12

Vertical Autoclave LVA-L12

  • Capacity : 110 L
  • Number of baskets : 3
  • Sterilization temperature : 105 °C to 138 °C
  • Working environment temperature : 5 °C to 45 °C
Vertical Autoclave LVA-A14

Vertical Autoclave LVA-A14

  • Capacity : 120 L
  • Maximum Working Pressure : 0.23 MPa
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
Vertical Autoclave LVA-O13

Vertical Autoclave LVA-O13

  • Capacity : 100 L
  • Chamber Volume : Ø450 × 650 mm
  • Working Sterilization Temperature : 134℃
  • Sterilization Temperature : 116℃ to 134℃
Vertical Laboratory Autoclave LVA-G11
Vertical Laboratory Autoclave LVA-G11
  • Capacity : 50L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Chamber Dimension ( Φ × D ) : 340 × 550 mm
Vertical Autoclave LVA-E24
Vertical Autoclave LVA-E24
  • Volume of Chamber : 80 L
  • Chamber thickness : 2 mm
  • Working temperature : 50 °C to 134 °C
  • Working pressure : 0.217 MPa
Vertical Laboratory Autoclave LVA-C12

Vertical Laboratory Autoclave LVA-C12

  • Capacity : 75 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Chamber Dimension ( Φ × D ) : 400 × 600 mm
Vertical Autoclave LVA-H15

Vertical Autoclave LVA-H15

  • Chamber Capacity : 200 L
  • Working Pressure : 0 to 0.22 MPa
  • Working Temperature Range : 105 to 134℃
  • Sterilization Time : 0 to 99 min or 0 to 99 hr 59 min
Vertical Autoclave LVA-H12

Vertical Autoclave LVA-H12

  • Capacity : 75 L
  • Working Pressure : 0 to 0.22 MPa
  • Working Temperature Range : 105 to 134°C
  • Sterilization Time : 0 to 99 min or 0 to 99 hour 59 min

Vertical Autoclave LVA-E21 FAQ's
  • Yes, the Vertical Autoclave is capable of sterilizing liquids, including culture media and laboratory reagents. It includes a specialized cycle that uses slow exhaust to prevent boil-over, ensuring the integrity of the liquids. Users must use heat-resistant glassware or approved containers for liquid sterilization to avoid breakage. After the cycle, a proper cooling period should be observed before handling. This function is especially useful in microbiology and cell culture labs.

  • The Vertical Autoclave comes equipped with multiple safety mechanisms to protect both the operator and the equipment. These include an automatic pressure-locking lid, over-temperature and over-pressure protection, a pressure release valve, and an audible alarm system. The locking system prevents the lid from being opened during pressurized cycles, eliminating the risk of accidents. Additionally, the insulated outer body ensures user safety from high temperatures. Together, these features promote safe and reliable operation.

  • Yes, like all autoclaves, the Vertical Autoclave requires periodic maintenance to ensure optimal performance and longevity. Regular checks should include inspecting the gasket seal, cleaning the chamber, and verifying that the drainage and venting systems are functioning properly. It's also recommended to run biological and chemical indicator tests regularly to confirm sterilization effectiveness. Manufacturer guidelines should be followed for preventive maintenance schedules. Proper care minimizes downtime and enhances the autoclave’s efficiency.

  • Yes, the Vertical Autoclave is highly suitable for sterilizing surgical instruments, dental tools, and reusable medical equipment. It provides a reliable and consistent sterilization process, making it ideal for operating rooms, outpatient clinics, and dental practices. Its safety features, such as pressure interlocks and automatic shut-off, make it safe for clinical environments. With the use of stainless-steel construction, it also ensures hygiene and corrosion resistance. This guarantees patient safety and regulatory compliance.

  • The Vertical Autoclave is compatible with a wide range of heat-resistant materials, including borosilicate glassware, stainless steel instruments, autoclavable plastics, and culture media containers. However, items made of low-melting plastics, sealed containers, or volatile substances should not be autoclaved. For best results, materials should be arranged to allow steam circulation and prevent cold spots. It’s important to consult the material manufacturer’s guidelines to ensure compatibility with steam sterilization. Using the correct materials ensures safety, effectiveness, and longer equipment life.

Post your question?

Our experts are here to help!

Vertical Autoclave:
Vertical Autoclave LVA-L12, Vertical Autoclave LVA-A14, Vertical Autoclave LVA-O13, Vertical Laboratory Autoclave LVA-G11, Vertical Autoclave LVA-E24, Vertical Laboratory Autoclave LVA-C12, Vertical Autoclave LVA-H15, Vertical Autoclave LVA-H12, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.