Type II Water Purification System LTWP -B14 is a 80 L capacited revolutionary, modular design which helps in elimination of large amount of salts and other minerals from water using 2 stages of RO. It provides Type II level water with consistency and reliability with a TOC level of < 20 ppb. Remove approximately 98% of inorganic ions and 99% of all dissolved organic substances. Equipped with easy replaceable filters. It’s designed to deliver compliant purified water with clear quality parameters and care free maintenance
Request QuoteOutput of Pure water | ≥ 50 L / hr. |
Process | Double Pass RO system |
Water Type | Type II |
Water Tank capacity | 80 L |
Configuration | Floor Standing |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 10-16 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 20 ppb |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 550 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 40 kg |
Model | Output of Pure water | Process | Water Type | Water Tank capacity | Configuration | Output of Ultrapure water | Resistivity at 25 °C | Conductivity at 25 °C | TOC | Absorbance ( 254 nm ) | Reactive Silica ( SiO2 ) | Heavy metal | Electrical requirements | Power | Dimensions ( L x W x H ) | Weight |
LTWP-B10 | ≥ 10 L / hr. | Double Pass RO system | Type II | 30 L | Benchtop | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 5 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 150 W | 340 x 550 x 530 mm | 40 kg |
LTWP-B11 | ≥ 20 L / hr. | Double Pass RO system | Type II | 30 L | Benchtop | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 5 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 200 W | 340 x 550 x 530 mm | 40 kg |
LTWP-B12 | ≥ 30 L / hr. | Double Pass RO system | Type II | 30 L | Benchtop | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 5 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 450 W | 340 x 550 x 530 mm | 40 kg |
LTWP-B13 | ≥ 40 L / hr. | Double Pass RO system | Type II | 80 L | Floor Standing | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 5 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 450 W | 340 x 550 x 530 mm | 40 kg |
LTWP-B14 | ≥ 50 L / hr. | Double Pass RO system | Type II | 80 L | Floor Standing | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 5 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 550 W | 340 x 550 x 530 mm | 40 kg |
LTWP-A10 | ≥ 10 L / hr. | Single Pass RO system | Type II | 30 L | Benchtop | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 10 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 100 W | 340 x 550 x 530 mm | 35 kg |
LTWP-A11 | ≥ 20 L / hr. | Single Pass RO system | Type II | 30 L | Benchtop | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 10 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 150 W | 340 x 550 x 530 mm | 35 kg |
LTWP-A12 | ≥ 30 L / hr. | Single Pass RO system | Type II | 30 L | Benchtop | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 10 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 200 W | 340 x 550 x 530 mm | 35 kg |
LTWP-A13 | ≥ 40 L / hr. | Single Pass RO system | Type II | 80 L | Floor Standing | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 10 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 200 W | 340 x 550 x 530 mm | 35 kg |
LTWP-A14 | ≥ 50 L / hr. | Single Pass RO system | Type II | 80 L | Floor Standing | ≥ 1- 1.5 L / min | 10-16 M Ω. cm | ≤ 10 µs / cm | < 20 ppb | ≤ 0.001 | < 0.01 ppm | < 0.01 ppm | 220 V / 50 Hz | ≥ 350 W | 340 x 550 x 530 mm | 35 kg |