Haze Meter LHM-A10 uses CIE-A, CIE-C, and CIE-D65 light sources to measure haze and transmittance. It supports a broad chromaticity index range, including A, C, D50–D75, F1–F12, and more. This complies with international ASTM and ISO standards, ensuring accurate and reliable results. It features an open sample bin, making it easy to test various sample sizes, and includes multiple measuring fixtures to suit different applications. Our haze meter is perfect for measuring colour, haze, spectral transmittance, and total transmittance in transparent and translucent materials such as plastic, film, glass, LCD panels, and touch screens.

Haze Meter LHM-A10( FRONT VIEW)
Haze Meter LHM-A10 ( SIDE VIEW)
Haze Meter LHM-A10 ( SIDE VIEW)
Haze Meter LHM-A10 (TOP VIEW)
Request Quote
Light Source Haze / Transmittance: CIE-A, CIE-C, CIE-D65 Chromaticity Index: A, C, D50, D55, D65, D75, F1–F12, CMF, U30, DLF, NBF, TL83, TL84
Standards ASTM D1003/D1044, ISO 13468 / ISO 14782, JIS K 7105 / K 7361 / K 7136, GB/T 2410-08, CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil 7, JIS Z8722 Condition C
Parameters Measured Haze (HAZE), Transmittance (T), Spectral Transmittance CIE Lab, LCh, CIE Luv, XYZ, Yxy, Hunter Lab, Munsell, MI, CMYK Whiteness (ASTM E313-00/73, CIE/ISO, etc.) Yellow Index (ASTM D1925, E313-00/73) Tint (ASTM E313-00), Heterochromatic Index Milm APHA, Pt-Co, Gardner Color Difference: ΔEab, ΔECH, ΔEuv, ΔEcmc(2:1)/ (1:1), ΔE94, ΔE00
Measuring Range 0 to 100% (Haze, Transmittance)
Spectral Response CIE Spectrum Function Y/V(λ)
Wavelength Range 400 to 700 nm
Wavelength Interval 10 nm
Geometry 0/d
Illumination Area / Aperture 16.5 mm / 21 mm
Resolution 0.01 unit
Repeatability Haze < 10%: ≤0.05%, Haze ≥ 10%: ≤0.1% Transmittance: ≤0.1%
Sample Size Thickness ≤ 145 mm
Display 7-inch Touch Screen
Data Storage 20,000 values
Interface USB
Working Conditions 5 to 45°C, ≤80% RH (at 35°C), no condensation
Storage Temperature -20 to 45°C, ≤80% RH (at 35°C), no condensation
Power Supply 110V / 220V / 240V
Dimension 598 × 247 × 366 mm
Packaging Dimension 700 × 330 × 550 mm
Net Weight 12 Kg
Gross Weight 20 Kg

· 7-inch intuitive touch screen

· Easy-to-use interface

· Includes standard PC software

· Open sample area 

Haze Meter LHM-A10 is commonly used in plastics, film, medical devices, cosmetics, and textile industries.

No.

Accessories Name

Quantity (Pcs)

1

Luggage Box

1

2

Film Fixture

1

3

Glass Cell Fixture

1

4

Sheet Material Fixture

1

5

Glass Cell/Sheet Material Fixture

1

6

Test Aperture

1

Haze Meter LHM-A10 | Measuring Range: 0 to 100% (Haze, Transmittance) | Spectral Response: CIE Spectrum Function Y/V(λ)
Haze Meter LHM-A10 | 7-inch intuitive touch screen | Easy-to-use interface

Models of Haze Meter

Labtron Haze Meters offer unmatched accuracy and effectiveness for assessing transparency in a variety of items. They have intuitive software, touch screens that are easy to operate, and streamlined procedures. Their diverse light sources provide versatility, and their open measuring surfaces may handle a range of sample sizes. These include extensive color analysis and adaptable fixtures to improve quality control. Our haze meters are crucial for accurate transmittance and clarity testing because of their enormous storage capacity.

Haze Meter LHM-C14

Haze Meter LHM-C14

  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm, Combined Light Source
  • Inductor : PD Array Detector CIE (λ) 2 Degree Visual Response
Haze And Transmittance Meter LHM-B10

Haze And Transmittance Meter LHM-B10

  • Haze Rate Measuring Range : 0 to 30.00%
  • Haze Rate Minimum Value : 0.01%
  • Haze Rate Measurement Accuracy : 0.1% when H is up to 0.5% and 0.3% when H is greater than 0.5%
  • Haze Rate Measurement Repeatability : 0.5% when H is up to 0.5% and 0.1% when H is greater than 0.5%
Haze Meter LHM-C12

Haze Meter LHM-C12

  • Measurement Aperture : Φ20mm / Φ15mm / Φ 8mm / Φ4mm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm, Combined Light Source
Haze Meter LHM-C13
Haze Meter LHM-C13
  • Sphere Size : Φ154 mm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : PD Array Detector CIE (λ) 2 Degree Visual Response
Haze Meter LHM-D11
Haze Meter LHM-D11
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : 256 Pixel Dual Array CMOS Image Sensor
Haze Meter LHM-D10

Haze Meter LHM-D10

  • Wavelength Range : 400 to 700 nm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : 256 Pixel Dual Array CMOS Image Sensor
Haze Meter LHM-E10

Haze Meter LHM-E10

  • Test Items : Total transmittance T.T/ parallel transmittance P.T/ scattering transmittance, light rate DF/ haze (HAZE)
  • Light Source : Mixed white LED (no need to replace)
  • Spot Diameter : 14 mm
  • Light Source Accuracy : 0.1%
Haze Meter LHM-D12

Haze Meter LHM-D12

  • Transmittance Range : 0 to 100 %
  • Sphere Size : Φ154 mm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
Haze Meter LHM-A10 FAQ's
  • A haze meter is an instrument used to measure the level of haze and light transmittance in transparent and translucent materials. This is crucial in industries like plastics, films, glass, and display technologies, where the clarity of materials affects both appearance and functionality. Labtron’s haze meters help manufacturers ensure that products meet optical clarity standards. By measuring parameters like haze percentage and total transmittance, these meters provide reliable data for quality control and product development. Whether it’s a touch screen, a medical device, or packaging film, knowing how light passes through the material can make a big difference in performance and visual appeal.

  • Labtron haze meters, including the LHM-A10, are designed to comply with international standards such as ASTM D1003, ISO 13468, and JIS K 7105, among others. These standards are recognized globally and set guidelines for accurate and repeatable measurements. By following these, Labtron ensures that its haze meters produce results that are both precise and comparable to results from other certified labs or equipment. Compliance also means users can trust the data when making decisions related to material quality, product approvals, or regulatory documentation.

  • Labtron haze meters come with features that make them easy to operate, even for users with minimal training. Most models are equipped with a 7-inch touch screen and an intuitive user interface, which simplifies navigation through different settings and test procedures. The open sample bin design allows users to test a wide range of sample shapes and sizes without needing extensive preparation. Labtron also provides standard PC software for data analysis and storage, and many haze meters can store up to 20,000 test values, making it easier to manage large batches of measurements.

  • Labtron haze meters are designed for a wide range of industries. In the plastics and film industry, they help assess the clarity of packaging materials. In the glass and LCD panel sectors, haze meters measure optical performance and light diffusion. Medical device manufacturers use them to verify the transparency of plastic components, while the cosmetics and textile industries rely on them to control product consistency. The Labtron LHM-A10, for example, can measure not just haze but also color indices, whiteness, yellow index, and other optical properties—making it a versatile tool across different quality assurance applications.

  • Labtron haze meters may employ integrating spheres in some models to collect scattered light more uniformly and accurately. The integrating sphere captures all scattered light at multiple angles, creating a diffuse and complete representation of haze rather than a narrow-angle sample. This is especially useful when dealing with materials that scatter in multiple directions or have textured surfaces. Labtron uses highly reflective inner coatings in these spheres to minimize absorption and maximize uniformity. Integrating spheres allow measurements that align with ISO and ASTM standards requiring full-angle haze capture. This design is critical for high-fidelity haze assessments.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.