Request A Quote
Haze Meter LHM-E10

Haze Meter LHM-E10

Haze Meter LHM-E10 features a dual light source with an accuracy of 0.1%. It analyzes test results, customizes haze judgments, and exports multiple test reports to Excel. The Haze Meter complies with various standards, including ISO, ASTM, and JIS. It is built with a high-accuracy mixed white LED light source that requires no replacement. Our Haze Meter is widely used in optical lens testing, glass resin scattering analysis, and surface inspection of films and plastics.

Request Quote
Test Items Total transmittance T.T/ parallel transmittance P.T/ scattering transmittance, light rate DF/ haze (HAZE)
Light Source Mixed white LED (no need to replace)
Spot Diameter 14 mm
Light Source Accuracy 0.1%
Dual Light Source Test and compensate 2 sets of light sources
Integrating Sphere Diameter 150 mm
Integrating Sphere Material PTFE (Polytetrafluoroethylene)
Sample Placement Vertical or horizontal placement based on sample
TT Repeatability Less than 0.03%
Working Temperature 15 to 40°C
Working Humidity Humidity below 80%
Software System Windows 7/8/10
Connection Method USB
Foot Control Optional
Voltage And Power Requirement AC110 to 240V, 20VA (10VA standby)
Dimension 344 × 294 × 474 mm
  • High test accuracy
  • USB connectivity
  • PTFE integrating sphere
  • Compact design

Our Haze Meter LHM-E10  is widely used in industries where light scattering, transmittance, and haze need to be accurately measured. It is particularly suitable for applications such as optical lens wear testing, glass resin scattering analysis, and film plastic surface inspection.

Download catalog for
Haze Meter LHM-E10 Catalog

Haze Meter LHM-E10 | Test Items	Total transmittance T.T | Light Source	Mixed white LED |  Spot Diameter	14 mm
Haze Meter LHM-E10 |High test accuracy | USB connectivity | PTFE integrating sphere | Compact design

Models of Haze Meter

Labtron Haze Meters offer unmatched accuracy and effectiveness for assessing transparency in a variety of items. They have intuitive software, touch screens that are easy to operate, and streamlined procedures. Their diverse light sources provide versatility, and their open measuring surfaces may handle a range of sample sizes. These include extensive color analysis and adaptable fixtures to improve quality control. Our haze meters are crucial for accurate transmittance and clarity testing because of their enormous storage capacity.

Haze Meter LHM-C10

Haze Meter LHM-C10

  • Wavelength Range : 400 to 700nm
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : 256 Pixel Dual Array CMOS Image Sensor
Haze And Transmittance Meter LHM-B10

Haze And Transmittance Meter LHM-B10

  • Haze Rate Measuring Range : 0 to 30.00%
  • Haze Rate Minimum Value : 0.01%
  • Haze Rate Measurement Accuracy : 0.1% when H is up to 0.5% and 0.3% when H is greater than 0.5%
  • Haze Rate Measurement Repeatability : 0.5% when H is up to 0.5% and 0.1% when H is greater than 0.5%
Haze Meter LHM-A10

Haze Meter LHM-A10

  • Light Source : Haze / Transmittance: CIE-A, CIE-C, CIE-D65 Chromaticity Index: A, C, D50, D55, D65, D75, F1–F12, CMF, U30, DLF, NBF, TL83, TL84
  • Standards : ASTM D1003/D1044, ISO 13468 / ISO 14782, JIS K 7105 / K 7361 / K 7136, GB/T 2410-08, CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil 7, JIS Z8722 Condition C
  • Parameters Measured : Haze (HAZE), Transmittance (T), Spectral Transmittance CIE Lab, LCh, CIE Luv, XYZ, Yxy, Hunter Lab, Munsell, MI, CMYK Whiteness (ASTM E313-00/73, CIE/ISO, etc.) Yellow Index (ASTM D1925, E313-00/73) Tint (ASTM E313-00), Heterochromatic Index Milm APHA, Pt-Co, Gardner Color Difference: ΔEab, ΔECH, ΔEuv, ΔEcmc(2:1)/ (1:1), ΔE94, ΔE00
  • Measuring Range : 0 to 100% (Haze, Transmittance)
Haze Meter LHM-D10
Haze Meter LHM-D10
  • Wavelength Range : 400 to 700 nm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : 256 Pixel Dual Array CMOS Image Sensor
Haze Meter LHM-C11
Haze Meter LHM-C11
  • Viewing Angle : 2°
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : PD Array Detector CIE (λ) 2 Degree Visual Response
Haze Meter LHM-C14

Haze Meter LHM-C14

  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm, Combined Light Source
  • Inductor : PD Array Detector CIE (λ) 2 Degree Visual Response
Haze Meter LHM-D12

Haze Meter LHM-D12

  • Transmittance Range : 0 to 100 %
  • Sphere Size : Φ154 mm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
Haze Meter LHM-C13

Haze Meter LHM-C13

  • Sphere Size : Φ154 mm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : PD Array Detector CIE (λ) 2 Degree Visual Response