Request A Quote
Haze And Transmittance Meter LHM-B10

Haze And Transmittance Meter LHM-B10

Haze and Transmittance Meter LHM-B10 offers measuring range that includes a light transmittance rate of 0 to 100% and a haze rate of 0 to 30%. It operates using a collimated illumination system with a diffuse field of view. The meter incorporates a digital LED display and a BCD code serial-output print interface. Additionally it has a DC12V 50W tungsten halogen light source with a color temperature chip. Our meter is ideal for research institutions and industries requiring high-precision clarity and turbidity analysis.

Request Quote
Haze Rate Measuring Range 0 to 30.00%
Haze Rate Minimum Value 0.01%
Haze Rate Measurement Accuracy 0.1% when H is up to 0.5% and 0.3% when H is greater than 0.5%
Haze Rate Measurement Repeatability 0.5% when H is up to 0.5% and 0.1% when H is greater than 0.5%
Light Transmittance Rate Measuring Range 0 to 100.0%
Light Transmittance Rate Minimum Value 0.1%
Light Transmittance Rate Accuracy 1 %
Light Transmittance Rate Repeatability 0.5%
Preheating Time 1 min
Sample Size Inlet window: Ф 25 mm
Outlet window: Ф 21 mm
Internal Illumination Source DC12V 50W tungsten halogen light source + color temperature chip
Observation Light Source C, A, D65
Power Supply AC 220 V, 50 Hz
  • Multiple continuous testing

  • Automatic operation

  • Versatile sample size compatibility

  • Silicon photoelectric cell as receiver

  • Compact design

Our Haze and Transmittance Meter LHM-B10 is used in industries such as plastics, packaging, coatings, and inks to measure material clarity and light diffusion. It is essential for quality control, research, and development, ensuring compliance with transparency and haze standards.

Fixture × 1 set

Power cord × 1 piece

Models of Haze Meter

Labtron Haze Meters offer unmatched accuracy and effectiveness for assessing transparency in a variety of items. They have intuitive software, touch screens that are easy to operate, and streamlined procedures. Their diverse light sources provide versatility, and their open measuring surfaces may handle a range of sample sizes. These include extensive color analysis and adaptable fixtures to improve quality control. Our haze meters are crucial for accurate transmittance and clarity testing because of their enormous storage capacity.

Haze Meter LHM-D10

Haze Meter LHM-D10

  • Wavelength Range : 400 to 700 nm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : 256 Pixel Dual Array CMOS Image Sensor
Haze Meter LHM-C11

Haze Meter LHM-C11

  • Viewing Angle : 2°
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : PD Array Detector CIE (λ) 2 Degree Visual Response
Haze Meter LHM-D12

Haze Meter LHM-D12

  • Transmittance Range : 0 to 100 %
  • Sphere Size : Φ154 mm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
Haze Meter LHM-C10
Haze Meter LHM-C10
  • Wavelength Range : 400 to 700nm
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : 256 Pixel Dual Array CMOS Image Sensor
Haze Meter LHM-A10
Haze Meter LHM-A10
  • Light Source : Haze / Transmittance: CIE-A, CIE-C, CIE-D65 Chromaticity Index: A, C, D50, D55, D65, D75, F1–F12, CMF, U30, DLF, NBF, TL83, TL84
  • Standards : ASTM D1003/D1044, ISO 13468 / ISO 14782, JIS K 7105 / K 7361 / K 7136, GB/T 2410-08, CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil 7, JIS Z8722 Condition C
  • Parameters Measured : Haze (HAZE), Transmittance (T), Spectral Transmittance CIE Lab, LCh, CIE Luv, XYZ, Yxy, Hunter Lab, Munsell, MI, CMYK Whiteness (ASTM E313-00/73, CIE/ISO, etc.) Yellow Index (ASTM D1925, E313-00/73) Tint (ASTM E313-00), Heterochromatic Index Milm APHA, Pt-Co, Gardner Color Difference: ΔEab, ΔECH, ΔEuv, ΔEcmc(2:1)/ (1:1), ΔE94, ΔE00
  • Measuring Range : 0 to 100% (Haze, Transmittance)
Haze Meter LHM-D11

Haze Meter LHM-D11

  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : 256 Pixel Dual Array CMOS Image Sensor
Haze Meter LHM-E10

Haze Meter LHM-E10

  • Test Items : Total transmittance T.T/ parallel transmittance P.T/ scattering transmittance, light rate DF/ haze (HAZE)
  • Light Source : Mixed white LED (no need to replace)
  • Spot Diameter : 14 mm
  • Light Source Accuracy : 0.1%
Haze Meter LHM-C13

Haze Meter LHM-C13

  • Sphere Size : Φ154 mm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : PD Array Detector CIE (λ) 2 Degree Visual Response

Haze And Transmittance Meter LHM-B10 FAQ's
  • Labtron’s Haze and Transmittance Meter is designed to test the optical properties of various transparent and semi-transparent materials. It is commonly used for plastic films, sheets, coatings, packaging films, and inks. These materials are widely used in industries such as packaging, automotive, electronics, and research laboratories, where clarity and light diffusion are critical factors. The meter helps manufacturers ensure their products meet the required transparency and haze standards for optimal performance and aesthetics.

  • Our Haze and Transmittance Meter measures haze and transmittance using a collimated illumination system combined with an integrating sphere. It directs a light source through the sample, and a silicon photoelectric receiver detects the transmitted light. By analyzing the intensity and scattering of light, the system calculates the transmittance percentage, which represents the amount of light passing through the material, and the haze percentage, which indicates the level of light diffusion. This method ensures precise and consistent results, making it suitable for industrial and research applications.

  • This Haze and Transmittance Meter requires a preheating time of approximately one minute before it is ready for testing. This brief warm-up period ensures that the light source and electronic components reach a stable operating condition, preventing fluctuations in measurement accuracy. The quick preheating time makes the device efficient for routine quality control checks in industrial environments.

  • Yes, our Haze and Transmittance Meter features an advanced automatic operating system that simplifies the testing process. The instrument can automatically switch between haze and transmittance measurements, perform necessary corrections, and analyze data with a built-in microcomputer processing system. Additionally, it supports multiple continuous tests and calculates average values, ensuring efficient and reliable operation with minimal user intervention.

  • Labtron’s Haze and Transmittance Meter is equipped with a BCD code serial output print interface, which allows users to connect the device to external printers or data storage systems. This feature enables seamless recording of measurement results, making it easier to track quality control data over time and generate reports for analysis. The ability to print or store results helps industries maintain accurate documentation for compliance with regulatory standards.

Post your question?

Our experts are here to help!

Haze Meter:
Haze Meter LHM-D10, Haze Meter LHM-C11, Haze Meter LHM-D12, Haze Meter LHM-C10, Haze Meter LHM-A10, Haze Meter LHM-D11, Haze Meter LHM-E10, Haze Meter LHM-C13, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.