Haze Meter LHM-C11 features a 2° viewing angle for precise measurement aligned with standard observer conditions for accurate visual assessment. It includes advanced filter technology, improving accuracy by minimizing stray light and enhancing signal clarity. The device has a high-speed measurement mode, providing rapid gloss readings with quick response times. Our haze meter offers high haze repeatability for reliable measurement with minimal variations.

Haze Meter LHM-C11_ Side View
Haze Meter LHM-C11_ Side View
Haze Meter LHM-C11 _Front View
Haze Meter LHM_C11 Video
Request Quote
Viewing Angle 2°
Sphere Size Φ154 mm
Illumination Source 400 to 700 nm Combined Light Source
Inductor PD Array Detector CIE (λ) 2 Degree Visual Response
Transmittance Range 0 to 100%
Measurement Aperture Φ20mm / Φ15mm / Φ 8mm / Φ4mm
Sample Size Thickness < 170
Other Indices Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T(ASTM)
Illuminants D 65, A, C
Measurement Time 1.5 s
Haze Resolution 0.01 unit
Haze Repeatability Φ20 mm, within 0.1
Inter –Instrument Error Φ20 mm, within 0.4
Data Storage Standard: 1000 Pcs, Sample: 20000 Pcs
Operating Temperature 0°C to 40°C
Storage Temperature -20°C to -50°C
Power Consumption 24 V DC, 3A Power Adapter
Dimensions (L× W× H) 290× 211 × 511 mm
Weight 7.6 kg
  • Multichannel Light Measurement

  • Integrated Sample Holder

  • Extended Wavelength Accuracy

  • Automatic Calibration Mode

  • Built-in Rechargeable Battery

Haze Meter LHM-C11 evaluates the optical clarity of materials by measuring the amount of light scattered. It plays a key role in the coating and packaging industries in determining the haze of packaging material and evaluating the coating on glass surfaces.

Accessories Name

Quantity

0 % Calibration Box

1

Aperture

1

 

Haze Meter LHM-C11 | Sphere Size: Φ154 | Illumination Source : 400 to 700 nm
Haze Meter LHM-C10 | Multichannel Light Measurement | Integrated Sample Holder


Models of Haze Meter

Labtron Haze Meters offer unmatched accuracy and effectiveness for assessing transparency in a variety of items. They have intuitive software, touch screens that are easy to operate, and streamlined procedures. Their diverse light sources provide versatility, and their open measuring surfaces may handle a range of sample sizes. These include extensive color analysis and adaptable fixtures to improve quality control. Our haze meters are crucial for accurate transmittance and clarity testing because of their enormous storage capacity.

Haze Meter LHM-C14

Haze Meter LHM-C14

  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm, Combined Light Source
  • Inductor : PD Array Detector CIE (λ) 2 Degree Visual Response
Haze Meter LHM-C12

Haze Meter LHM-C12

  • Measurement Aperture : Φ20mm / Φ15mm / Φ 8mm / Φ4mm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm, Combined Light Source
Haze And Transmittance Meter LHM-B10

Haze And Transmittance Meter LHM-B10

  • Haze Rate Measuring Range : 0 to 30.00%
  • Haze Rate Minimum Value : 0.01%
  • Haze Rate Measurement Accuracy : 0.1% when H is up to 0.5% and 0.3% when H is greater than 0.5%
  • Haze Rate Measurement Repeatability : 0.5% when H is up to 0.5% and 0.1% when H is greater than 0.5%
Color & Haze meter LHM-A11
Color & Haze meter LHM-A11
  • Light source : CIE-A,CIE-C,CIE-D65Chromaticity Value:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84
  • Standards : ASTM D1003/D1044,ISO13468/ISO14782 & CIE No.15,ISO 7724/1,ASTM E1164
  • Parameters : HAZE, Transmittance(T),Spectral TransmittanceWhiteness Index (ASTM E313-00,ASTM E313-73,CIE/ISO AATCC,Hunter, Taube Berger Stensby)Yellowness Index (ASTM D1925,ASTM E313-00,ASTM E313-73)Tint(ASTM E313-00), Metamerism Index, MilmAPHA, Pt-Co, Gardner, Color Difference(ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00)
  • Spectral response : CIE Luminosity function y
Haze Meter LHM-D11
Haze Meter LHM-D11
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Sphere Size : Φ154 mm
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : 256 Pixel Dual Array CMOS Image Sensor
Haze Meter LHM-A10

Haze Meter LHM-A10

  • Light Source : Haze / Transmittance: CIE-A, CIE-C, CIE-D65 Chromaticity Index: A, C, D50, D55, D65, D75, F1–F12, CMF, U30, DLF, NBF, TL83, TL84
  • Standards : ASTM D1003/D1044, ISO 13468 / ISO 14782, JIS K 7105 / K 7361 / K 7136, GB/T 2410-08, CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil 7, JIS Z8722 Condition C
  • Parameters Measured : Haze (HAZE), Transmittance (T), Spectral Transmittance CIE Lab, LCh, CIE Luv, XYZ, Yxy, Hunter Lab, Munsell, MI, CMYK Whiteness (ASTM E313-00/73, CIE/ISO, etc.) Yellow Index (ASTM D1925, E313-00/73) Tint (ASTM E313-00), Heterochromatic Index Milm APHA, Pt-Co, Gardner Color Difference: ΔEab, ΔECH, ΔEuv, ΔEcmc(2:1)/ (1:1), ΔE94, ΔE00
  • Measuring Range : 0 to 100% (Haze, Transmittance)
Haze Meter LHM-D12

Haze Meter LHM-D12

  • Transmittance Range : 0 to 100 %
  • Sphere Size : Φ154 mm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
Haze Meter LHM-D10

Haze Meter LHM-D10

  • Wavelength Range : 400 to 700 nm
  • Optical Geometry : Transmittance: 0/D (Parallel Light Illumination, Diffuse Viewing)
  • Illumination Source : 400 to 700 nm Combined Light Source
  • Inductor : 256 Pixel Dual Array CMOS Image Sensor
Haze Meter LHM-C11 FAQ's
  • Labtron haze meters are sensitive to even minor surface contamination, such as dust, fingerprints, or residue, which can scatter light and increase haze values. This sensitivity allows operators to identify whether a surface is clean and properly prepared before packaging or further processing. In production environments, unexpected spikes in haze can quickly indicate contamination events. Labtron’s precision optics and repeatable measurements help pinpoint surface-related issues. Regular use ensures product consistency by highlighting deviations in surface quality. By comparing pre and post-cleaning samples, users can validate cleaning procedures. This enhances both product appearance and functional quality.

  • Labtron haze meters are designed to accommodate a wide range of transparent and translucent materials, including plastic films, rigid sheets, coated glass, and optical-grade polymers. The device works best with flat samples, but optional fixtures are available for slightly curved or flexible items. Samples typically range from 0.1 mm to several millimeter in thickness. Labtron models also include features to compensate for minor dimensional variations. For multilayer or laminated materials, the meter captures the cumulative haze effect across all layers. The versatility of labtron's haze meters makes them suitable for diverse industries, from packaging to medical devices.

  • Labtron supplies premium haze meters. They are instrumental in the production of optical films used in electronics, displays, and solar panels. These applications require extremely low haze and high clarity to maintain brightness and image fidelity. Labtron meters provide precise quantification of haze at low levels, often below 1%, which is critical for high-end optical applications. The meters help manufacturers monitor changes due to coatings, lamination, or environmental exposure. With Labtron’s high-resolution detection, even minimal scattering caused by micro-defects or impurities can be detected. This ensures consistent quality and optimal performance of advanced optical films. Labtron’s data helps guide process optimization and material selection.

  • Labtron haze meters are commonly used to test food packaging films, containers, and wraps where product visibility is a selling point. Regulatory bodies often require transparency verification for visual inspection and consumer acceptance. Labtron haze meters help ensure packaging does not appear cloudy or discolored due to raw material inconsistencies or contamination. They support evaluations during material development, production, and storage testing. Labtron models can test multilayer films that include barrier or UV-protection layers. The non-destructive testing method ensures materials remain usable after analysis. This helps manufacturers meet food safety and visual quality standards effectively.

  • Labtron haze meters are sensitive to material degradation over time due to UV exposure, humidity, and thermal cycling. As materials age, they may develop internal defects or surface changes that scatter light, increasing haze values. Labtron provides consistent baseline and time-lapse readings to monitor such effects during accelerated aging tests. This makes it a valuable tool for product lifespan evaluation and durability studies. The data can inform material improvements or predict product performance under real-world conditions. Labtron haze meters are used in industries such as construction, automotive, and solar, where exposure-related clarity loss is critical. Reliable detection supports warranty and compliance documentation.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.