| Capacity | 150 L |
| Sterilization Temperature | 134 °C |
| Sterilization Pressure | 0.22 MPa |
| Timer Range | 0 - 60 minutes |
| Heat Average | ≤ ± 1 ℃ |
| Chamber Dimensions ( Φ × D ) | 440 × 1000 mm |
| Product Dimension ( L × W × H ) | 1400 × 600 × 1300 mm |
| Net Weight | 240 kg |
| Gross Weight | 320kg |
| Power Supply | 9 kW / AC 380 V 50 Hz |
Horizontal autoclave with cylindrical shape is suitable for medical, laboratory, microbiological, clinical use and to sterile the waste before discarding.
Download catalog for
Horizontal Laboratory Autoclave LHA-B10 Catalog
Available Range :
Horizontal Laboratory Autoclave LHA-K10 : 100 L Horizontal Laboratory Autoclave LHA-F17 : 10000L Horizontal Laboratory Autoclave LHA-J10 : 100L Horizontal Laboratory Autoclave LHA-D18 : 120 L Horizontal Laboratory Autoclave LHA-D14 : 1200 L Horizontal Laboratory Autoclave LHA-D20 : 150 L Horizontal Laboratory Autoclave LHA-D15 : 1500 L Horizontal Laboratory Autoclave LHA-D21 : 1500L Horizontal Laboratory Autoclave LHA-B15 : 150L Horizontal Laboratory Autoclave LHA-I14 : 180 L Horizontal Laboratory Autoclave LHA-B11 : 200 L Horizontal Laboratory Autoclave LHA-D16 : 2000 L Horizontal Laboratory Autoclave LHA-I16 : 2000L Horizontal Laboratory Autoclave LHA-B18 : 200L Horizontal Laboratory Autoclave LHA-D10 : 250 L Horizontal Laboratory Autoclave LHA-B12 : 280 L Horizontal Laboratory Autoclave LHA-A10 : 300 L Horizontal Laboratory Autoclave LHA-B19 : 300L Horizontal Laboratory Autoclave LHA-D11 : 360 L Horizontal Laboratory Autoclave LHA-B13 : 400 L Horizontal Laboratory Autoclave LHA-A11 : 500 L Horizontal Laboratory Autoclave LHA-B20 : 500L Horizontal Laboratory Autoclave LHA-I10 : 60 L Horizontal Laboratory Autoclave LHA-D12 : 600 L Horizontal Laboratory Autoclave LHA-I11 : 80 L Horizontal Laboratory Autoclave LHA-D13 : 800 L Horizontal Laboratory Autoclave LHA-I20 : 90 LLabtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.








Regular maintenance of the Horizontal Laboratory Autoclave LHA-B10 includes cleaning the chamber to prevent residue buildup. The water reservoir should be checked and refilled regularly for optimal performance. Door seals must be inspected to ensure an airtight closure and prevent leaks. Filters and drainage systems should be cleaned to maintain smooth operation. Routine upkeep enhances performance and extends the autoclave’s lifespan.
Labtron’s Horizontal Laboratory Autoclave is equipped with an automatic water-level detection system. If the water level is too low, an alarm alerts the user, preventing dry heating damage. The system automatically shuts off to avoid overheating and ensure safe operation. This feature protects internal components, extending the autoclave’s lifespan. Users can simply refill the water before restarting the cycle, ensuring smooth operation.
There is no need for constant supervision when using the Horizontal Laboratory Autoclave LHA-B10, as the system operates automatically once sterilization settings are configured. Real-time monitoring on the digital LCD keeps users informed about temperature, pressure, and cycle progress. Automated alarms provide instant alerts for any issues, ensuring a smooth and safe process. This hands-free operation minimizes workload and ensures consistent sterilization results without manual intervention. Pre-set programs optimize cycles for various loads, ensuring efficient and reliable sterilization.
The Horizontal Laboratory Autoclave is designed with safety features that prevent pausing or opening a cycle until pressure and temperature are safely reduced. This ensures the sterilization process is not interrupted, maintaining effectiveness. In case of a fault or emergency, the autoclave can automatically abort the cycle to prevent damage. Manual interruption is not recommended unless done strictly following Labtron’s guidelines. Attempting to stop the cycle without precautions may risk incomplete sterilization. These built-in controls ensure both user and equipment safety.
Yes, the Horizontal Laboratory Autoclave LHA-B10 is designed with energy efficiency in mind. Its advanced insulation reduces heat loss, lowering power consumption. Automatic shutdown after cycle completion prevents unnecessary energy use. The optimized heating system ensures power is used only when needed. Real-time monitoring prevents overheating, reducing energy waste while maintaining sterilization performance.
Achieving consistent and effective sterilization is made easy with the high-pressure steam system of Labtron’s Horizontal Laboratory Autoclave LHA-B10. A microprocessor-controlled mechanism ensures precise temperature and pressure regulation for optimal results. Built-in safety features, including automatic shutoff, door interlock, and low-water alarms, provide added protection. The sturdy construction is designed for long-term performance in laboratory settings. An automated drying function eliminates residual moisture, preventing microbial contamination.