Horizontal Laboratory Autoclave LHA-B10

Horizontal Laboratory Autoclave LHA-B10

Horizontal Laboratory Autoclave LHA-B10 is a microprocessor-controlled automatic autoclave.It has a capacity of 150 L and a maximum working temperature of 134 °C. Equipped with safety features like automatic shutoff, preventing overload of current, auto protection against raised temperature and pressure making a reliable and user friendly device.

Horizontal Laboratory Autoclave LHA-B10
Horizontal Laboratory Autoclave LHA-B10
Horizontal Laboratory Autoclave LHA-B10
Horizontal Laboratory Autoclave LHA-B10
Request Quote
Capacity 150 L
Sterilization Temperature 134 °C
Sterilization Pressure 0.22 MPa
Timer Range 0 - 60 minutes
Heat Average ≤ ± 1 ℃
Chamber Dimensions ( Φ × D ) 440 × 1000 mm
Product Dimension ( L × W × H ) 1400 × 600 × 1300 mm
Net Weight 240 kg
Gross Weight 320kg
Power Supply 9 kW / AC 380 V 50 Hz
  • Microprocessor control with fully automatic cycles
  • Digital LCD display to monitor working status and parameters
  • Working pressure : 0.22 MPa
  • Working temperature : 134 ℃
  • Automated drying function
  • Door lock feature : Door cannot be opened till the pressure inside the chamber doesn’t fall to 0.027 MPa
  • Safe door lock system ensuring safety / protection during sterilization
  • Automatic power cut off with alarm with low water levels indication

Horizontal autoclave with cylindrical shape is suitable for medical, laboratory, microbiological, clinical use and to sterile the waste before discarding.

Models of Horizontal Autoclave

Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.

Horizontal Laboratory Autoclave LHA-B17

Horizontal Laboratory Autoclave LHA-B17

  • Capacity : 150L
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
Horizontal Laboratory Autoclave LHA-H10

Horizontal Laboratory Autoclave LHA-H10

  • Capacity : 150 L
  • Working Pressure : 0 to 0.22 MPa
  • Working Temperature : 134 °C
  • Temperature Range : 0 to 134 °C
Horizontal Laboratory Autoclave LHA-E12

Horizontal Laboratory Autoclave LHA-E12

  • Capacity : 280 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Timer Range : 0 - 99 minutes
Horizontal Laboratory Autoclave LHA-H12
Horizontal Laboratory Autoclave LHA-H12
  • Capacity : 280 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Timer Range : 0 - 99 minutes
Horizontal Laboratory Autoclave LHA-D27
Horizontal Laboratory Autoclave LHA-D27
  • Chamber Capacity : 250 Liters
  • Door Type : Double Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-E11

Horizontal Laboratory Autoclave LHA-E11

  • Capacity : 200 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Timer Range : 0 - 99 minutes
Horizontal Laboratory Autoclave LHA-D23

Horizontal Laboratory Autoclave LHA-D23

  • Chamber Capacity : 150 Liters
  • Door Type : Double Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-K15

Horizontal Laboratory Autoclave LHA-K15

  • Capacity : 200 L
  • Design Pressure : -0.1 / 0.25 MPa
  • Max Working Pressure : 0.23 MPa
  • Design Temperature : 139°C
Horizontal Laboratory Autoclave LHA-B10 FAQ's
  • Regular maintenance of the Horizontal Laboratory Autoclave LHA-B10 includes cleaning the chamber to prevent residue buildup. The water reservoir should be checked and refilled regularly for optimal performance. Door seals must be inspected to ensure an airtight closure and prevent leaks. Filters and drainage systems should be cleaned to maintain smooth operation. Routine upkeep enhances performance and extends the autoclave’s lifespan.

  • Labtron’s Horizontal Laboratory Autoclave is equipped with an automatic water-level detection system. If the water level is too low, an alarm alerts the user, preventing dry heating damage. The system automatically shuts off to avoid overheating and ensure safe operation. This feature protects internal components, extending the autoclave’s lifespan. Users can simply refill the water before restarting the cycle, ensuring smooth operation.

  • There is no need for constant supervision when using the Horizontal Laboratory Autoclave LHA-B10, as the system operates automatically once sterilization settings are configured. Real-time monitoring on the digital LCD keeps users informed about temperature, pressure, and cycle progress. Automated alarms provide instant alerts for any issues, ensuring a smooth and safe process. This hands-free operation minimizes workload and ensures consistent sterilization results without manual intervention. Pre-set programs optimize cycles for various loads, ensuring efficient and reliable sterilization.

  • The Horizontal Laboratory Autoclave is designed with safety features that prevent pausing or opening a cycle until pressure and temperature are safely reduced. This ensures the sterilization process is not interrupted, maintaining effectiveness. In case of a fault or emergency, the autoclave can automatically abort the cycle to prevent damage. Manual interruption is not recommended unless done strictly following Labtron’s guidelines. Attempting to stop the cycle without precautions may risk incomplete sterilization. These built-in controls ensure both user and equipment safety.

  • Yes, the Horizontal Laboratory Autoclave LHA-B10 is designed with energy efficiency in mind. Its advanced insulation reduces heat loss, lowering power consumption. Automatic shutdown after cycle completion prevents unnecessary energy use. The optimized heating system ensures power is used only when needed. Real-time monitoring prevents overheating, reducing energy waste while maintaining sterilization performance.

  • Achieving consistent and effective sterilization is made easy with the high-pressure steam system of Labtron’s Horizontal Laboratory Autoclave LHA-B10. A microprocessor-controlled mechanism ensures precise temperature and pressure regulation for optimal results. Built-in safety features, including automatic shutoff, door interlock, and low-water alarms, provide added protection. The sturdy construction is designed for long-term performance in laboratory settings. An automated drying function eliminates residual moisture, preventing microbial contamination.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.