Horizontal Laboratory Autoclave LHA-D11

Horizontal Laboratory Autoclave LHA-D11

Horizontal Laboratory Autoclave LHA-D11 offers a 360 L capacity for optimal sterilization. It features a fully automated production line with robot-assisted welding and automatic polishing. The patented sealing structure includes a welded sealing groove, integral door panel, and Parylene-coated hollow sealing ring. Its main body is made of stainless steel with a rectangular cross-section and annular reinforcement jacket. Our autoclave is ideal for biopharmaceutical, medical, and laboratory settings, efficiently sterilizing instruments and sterile clothing.

Request Quote
Capacity 360 L
Design Temperature 150 ℃
Temperature Uniformity ±1 ℃
Max. Working Temperature 139 ℃
Negative Pressure Pulsation Vacuum Amplitude -80 to 0 kPa, Times 3 to 9
Max. Working Pressure 0.28 MPa
Cross-Pressure Pulsation Amplitude -80 to 80 kPa, Times 1 to 9
Inner Chamber Design Pressure -0.1 / 0.3 MPa
Temperature Display Accuracy 0.1 ℃
Jacket Design Pressure 0.3 MPa
Pressure Display Accuracy 0.1 kPa
Built-in Steam Generator (if present) 1.0 MPa
Sterilization Temperature Control Accuracy ±0.2 ℃
Opening Pressure of Inner Chamber Safety Valve 0.28 MPa
Positive Pressure Pulsation 0 to 9
Opening Pressure of Jacket Safety Valve 0.28 MPa
Ultimate Vacuum -96 kPa
Steam Consumption 20 kg/C
Water Consumption 140 kg/C
Power 3-phase 380V, 50Hz, 2KW + 30KW
Chamber Dimensions (W×H×D) 610 × 610 × 1000 mm
Boundary Dimensions (L×W×H) 1450 × 1350 × 1950 mm
Weight 820 kg
  • Single-Door Interlock Design
  • Long-Lasting Silicone Seal
  • Reinforced Structural Jacket
  • Automatic Process Control
  • Integrated Traceability Interface

Our Horizontal Laboratory Autoclave LHA-D11 is ideal for biopharmaceuticals, medical, and laboratory settings, sterilizing instruments, sterile clothing, tubular instruments, rubber, liquids, medical waste, and other items requiring high sterilization efficiency and precise drying.

  • 1 Loading Cart + 1 Transfer Trolley
  • External Air Compressor

Models of Horizontal Autoclave

Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.

Horizontal Laboratory Autoclave LHA-B10

Horizontal Laboratory Autoclave LHA-B10

  • Capacity : 150 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Timer Range : 0 - 60 minutes
Horizontal Laboratory Autoclave LHA-I13

Horizontal Laboratory Autoclave LHA-I13

  • Capacity : 150 L
  • Designed Temperature : 150℃
  • Maximum Working Temperature : 139℃
  • Inner Chamber Pressure : -0.1 to 0.3 MPa
Horizontal Laboratory Autoclave LHA-D35

Horizontal Laboratory Autoclave LHA-D35

  • Chamber Capacity : 600 Liters
  • Door Type : Double Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-B17
Horizontal Laboratory Autoclave LHA-B17
  • Capacity : 150L
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
Horizontal Laboratory Autoclave LHA-D29
Horizontal Laboratory Autoclave LHA-D29
  • Chamber Capacity : 360 Liters
  • Door Type : Double Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-D16

Horizontal Laboratory Autoclave LHA-D16

  • Capacity : 2000 L
  • Sterilization Temperature : 139 °C
  • Sterilization Pressure : 0.22MPa
  • Steam Pressure and the Consumption : 0.4 - 0.6 MPa / 55 kg
Horizontal Laboratory Autoclave LHA-H12

Horizontal Laboratory Autoclave LHA-H12

  • Capacity : 280 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Timer Range : 0 - 99 minutes
Horizontal Laboratory Autoclave LHA-G11

Horizontal Laboratory Autoclave LHA-G11

  • Capacity : 200 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Timer Range : 0 - 60 minutes

Horizontal Laboratory Autoclave LHA-D11 FAQ's
  • Yes. For laboratories performing up to 3 sterilization cycles per day (~1440 L/day), compact DM water systems suitable for the Horizontal Laboratory Autoclave LHA-D11 can be recommended.

  • No. These are optional accessories that can be purchased separately for the Horizontal Laboratory Autoclave LHA-D11: • Loading cart • Transport trolley

  • No. Trays are included with the Horizontal Laboratory Autoclave LHA-D11, but baskets are not supplied.

  • A sterilization cycle in the Horizontal Laboratory Autoclave LHA-D11 takes approximately 45–60 minutes. This includes the heating, sterilization, and cooling phases.

  • • Steam Generator: Can use soft water, purified water, deionized, or distilled water. • Condenser & Vacuum Pump: Normal tap water is acceptable. Flow rate only affects the filling time and does not affect sterilization performance of the Horizontal Laboratory Autoclave LHA-D11.

  • IQ (Installation Qualification), OQ (Operational Qualification), and FAT (Factory Acceptance Test) documentation are available for the Horizontal Laboratory Autoclave LHA-D11. Charges for these documents are provided on request.

  • The inner chamber of the Horizontal Laboratory Autoclave LHA-D11 can be modified to 1000 × 600 × 900 mm (L × W × H). If the height is increased, the outer dimensions will also increase. Updated technical drawings will be provided within 5–7 working days after confirmation.

  • No. Increasing the chamber height to 900 mm does not change the price of the Horizontal Laboratory Autoclave LHA-D11.

  • The door height from the floor is around 800 mm. The door opening size is approximately 500 × 500 mm (W × H). The exact size may vary slightly depending on the final chamber dimensions of the Horizontal Laboratory Autoclave LHA-D11.

  • • Steam Generator: Requires demineralized, distilled, or purified water with conductivity between 1–10 µS/cm. Water pressure should be 0.15–0.3 MPa. • Condenser & Vacuum Pump: Normal tap water is acceptable, and water quality requirements are not strict.

  • Ultra-pure Milli-Q water (?0.1 µS/cm) is not recommended, as it may corrode internal components and affect steam generation. Purified Milli-Q water (1–10 µS/cm) is suitable for use in the Horizontal Laboratory Autoclave LHA-D11.

  • The recommended water flow rate is 5–8 L/min. For a 60-minute sterilization cycle, the Horizontal Laboratory Autoclave LHA-D11 consumes approximately 300–480 liters of water, depending on the operating mode and load size.

Post your question?

Our experts are here to help!

Horizontal Autoclave:
Horizontal Laboratory Autoclave LHA-B10, Horizontal Laboratory Autoclave LHA-I13, Horizontal Laboratory Autoclave LHA-D35, Horizontal Laboratory Autoclave LHA-B17, Horizontal Laboratory Autoclave LHA-D29, Horizontal Laboratory Autoclave LHA-D16, Horizontal Laboratory Autoclave LHA-H12, Horizontal Laboratory Autoclave LHA-G11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.