| Capacity | 300 L |
| Chamber Volume | Φ600 × 1240 mm |
| Chamber Thickness | 3.0 mm |
| Temperature Range | 50 °C to 134 °C |
| Working Environment | 5 °C to 45°C |
| Relative Humidity | 10% to 85% |
| Rated Working Pressure | 0.217 MPa |
| Sterilization Time Range | 0 to 99 h |
| Power Supply | 380 V |
| Rated Power | 9000 W |
| Packing Size | 1640 × 930 × 1900 mm |
| Dimension | 1550 × 820 × 1740 mm |
| Gross Weight | 335 Kg |
Compact Design with Large Capacity
Overheat and Overpressure Protection
Real-Time Cycle Status Display
Water Recycling System
Temperature and Pressure Interface Check
Our Horizontal Laboratory Autoclave LHA-C11 is widely used for sterilizing equipment, instruments, and materials across laboratories, hospitals, biotechnology units, veterinary clinics, agricultural research, food testing, cosmetic industries, dental labs, and public health departments.
Download catalog for
Horizontal Laboratory Autoclave LHA-C11 Catalog
Available Range :
Horizontal Laboratory Autoclave LHA-K10 : 100 L Horizontal Laboratory Autoclave LHA-F17 : 10000L Horizontal Laboratory Autoclave LHA-J10 : 100L Horizontal Laboratory Autoclave LHA-D18 : 120 L Horizontal Laboratory Autoclave LHA-D14 : 1200 L Horizontal Laboratory Autoclave LHA-D20 : 150 L Horizontal Laboratory Autoclave LHA-D15 : 1500 L Horizontal Laboratory Autoclave LHA-D21 : 1500L Horizontal Laboratory Autoclave LHA-B15 : 150L Horizontal Laboratory Autoclave LHA-I14 : 180 L Horizontal Laboratory Autoclave LHA-B11 : 200 L Horizontal Laboratory Autoclave LHA-D16 : 2000 L Horizontal Laboratory Autoclave LHA-I16 : 2000L Horizontal Laboratory Autoclave LHA-B18 : 200L Horizontal Laboratory Autoclave LHA-D10 : 250 L Horizontal Laboratory Autoclave LHA-B12 : 280 L Horizontal Laboratory Autoclave LHA-A10 : 300 L Horizontal Laboratory Autoclave LHA-B19 : 300L Horizontal Laboratory Autoclave LHA-D11 : 360 L Horizontal Laboratory Autoclave LHA-B13 : 400 L Horizontal Laboratory Autoclave LHA-A11 : 500 L Horizontal Laboratory Autoclave LHA-B20 : 500L Horizontal Laboratory Autoclave LHA-I10 : 60 L Horizontal Laboratory Autoclave LHA-D12 : 600 L Horizontal Laboratory Autoclave LHA-I11 : 80 L Horizontal Laboratory Autoclave LHA-D13 : 800 L Horizontal Laboratory Autoclave LHA-I20 : 90 L
Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.








A Horizontal Autoclave LHA-C11 ensures uniform sterilization by using advanced steam circulation systems that distribute steam evenly across the chamber. The design often incorporates fans or baffles to prevent steam pockets and cold spots, ensuring all items receive consistent heat exposure. Temperature and pressure sensors continuously monitor conditions at multiple points, providing real-time feedback to the control system. The autoclave adjusts steam flow and cycle time based on load type and volume, optimizing sterilization efficacy. This uniformity is critical for sterilizing complex or bulky loads without compromising safety or effectiveness. By maintaining precise control, the autoclave guarantees reliable sterilization results every cycle.
Selecting the correct sterilization cycle depends on the type of load, material sensitivity, and sterilization requirements. For example, solid instruments may require higher temperatures and longer exposure times than heat-sensitive plastics or liquids. The cycle must also consider the load’s density and volume, as larger or denser items need more steam penetration and time to sterilize effectively. Horizontal autoclaves often offer preset or customizable cycles to accommodate diverse needs, including gravity displacement, pre-vacuum, and liquid sterilization modes. Operators should also factor in cooling time and drying phases when applicable to ensure the sterilized items are safe to handle immediately after the cycle. Proper cycle selection helps prevent damage to delicate materials while ensuring complete microbial elimination. Consulting manufacturer guidelines and sterilization standards is essential for optimal cycle choice.
Regular maintenance is vital to keep a Horizontal Autoclave LHA-C11 functioning efficiently and prolong its service life. Daily tasks include cleaning the chamber interior to remove residue and ensuring the door seal is free from debris for proper closure. Periodic inspections of pressure valves, steam traps, and drain lines help prevent blockages that could impair operation. Calibration of temperature and pressure sensors should be done according to manufacturer recommendations to maintain sterilization accuracy. Lubricating moving parts, such as door hinges and locking mechanisms, reduces wear and tear. Additionally, water quality used in the autoclave should be monitored to avoid mineral buildup and corrosion inside the chamber. Scheduling professional servicing and software updates ensures all systems perform optimally and comply with safety standards.
Horizontal Autoclave LHA-C11 are designed with flexible chamber sizes and adjustable racks or trays to accommodate diverse load configurations. The front-loading design allows easy placement of large or bulky items, while modular shelving can be rearranged or removed for odd-shaped equipment. Many models include multiple sterilization programs tailored to different load types, such as solids, liquids, or porous materials, optimizing cycle parameters accordingly. Sensors inside the chamber assess the load’s thermal mass and adjust steam exposure time for thorough sterilization without overprocessing. This adaptability reduces turnaround times and increases throughput by allowing mixed loads in a single cycle.
The automatic water intake and refill system simplifies operation by maintaining the correct water level without manual intervention. It ensures the steam generator always has sufficient water to produce saturated steam for sterilization cycles, preventing interruptions or incomplete sterilization. This automation reduces the risk of operator error and enhances process reliability. The system also monitors water quality and volume, often alerting users to refill or maintenance needs. By managing water input efficiently, it helps conserve water and energy, supporting sustainable laboratory practices. Furthermore, automatic refilling minimizes downtime between cycles, increasing overall throughput. This feature is especially beneficial in high-volume settings where consistent performance and uptime are critical.