Horizontal Laboratory Autoclave LHA-D30 offers a 400-liter chamber capacity for high-performance sterilization in laboratory settings. Designed to withstand a temperature range of 105°C to 139°C, it ensures precise sterilization. Its sterilization and drying times are programmable, providing flexibility across diverse load types. It is ideal for large-scale sterilization demands in modern laboratories and sterile processing departments.

Horizontal Laboratory Autoclave LHA-D30
Horizontal Laboratory Autoclave LHA-D30
Horizontal Laboratory Autoclave LHA-D30
Request Quote
Chamber Capacity 400 Liters
Door Type Single Door
Control System PLC + HMI + Built-in Printer
Display 7.0-inch Color Touchscreen
Design Pressure –0.1 / 0.5 MPa
Working Pressure Range 0 to 0.25 MPa
Safety Valve Opening Pressure 0.28 MPa
Design Temperature 150°C
Working Temperature Range 105°C to 139°C
Temperature Control Accuracy ≤ ± 0.2°C
Temperature Display Accuracy 0.1°C
Temperature Equilibrium ≤ ± 0.5°C
Sterilization Time Range 0 to 999 min
Drying Time Range 0 to 999 min
Vacuum Rate –97 kPa
Vacuum System Liquid Ring Vacuum Pump (Pre & Post)
Steam Consumption per Cycle 21 kg
Water Consumption per Cycle 170 kg
Power Consumption 32 kW
Chamber Size (W × D × H) 652 × 690 × 850 mm
Outer Dimensions (W × D × H) 1350 × 1950 × 1200 mm
Net Weight 920 kg
  • Large Chamber Capacity
  • User-Friendly Interface
  • Robust Construction
  • Wide Temperature & Pressure Range
  • High Temperature Accuracy
  • Advanced Vacuum System
  • Flexible Operation Time
  • Built-In Safety Features
  • Efficient Resource Usage
  • High Power Performance
  • Compact Footprint

Our Horizontal Laboratory Autoclave LHA-D30 is widely used in Central Sterile Supply Departments (CSSD), laboratories, scientific research institutions, the pharmaceutical industry, and the food industry.

Horizontal Laboratory Autoclave LHA-D30 | Temperature Control Accuracy: ≤ ± 0.2°C | Working Pressure Range: 0 to 0.25 MPa
Horizontal Laboratory Autoclave LHA-D30 | Flexible Operation Time | Built-In Safety Features

Models of Horizontal Autoclave

Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.

Horizontal Laboratory Autoclave LHA-A11

Horizontal Laboratory Autoclave LHA-A11

  • Capacity : 500 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Timer Range : 0 - 99 minutes
Horizontal Laboratory Autoclave LHA-D28

Horizontal Laboratory Autoclave LHA-D28

  • Chamber Capacity : 360 Liters
  • Door Type : Single Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-D36

Horizontal Laboratory Autoclave LHA-D36

  • Chamber Capacity : 800 Liters
  • Door Type : Single Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-F14
Horizontal Laboratory Autoclave LHA-F14
  • Capacity : 1200 L
  • Sterilization Temperature : 139 °C
  • Sterilization Pressure : 0.25MPa
  • Steam Pressure and the Consumption : 0.4 - 0.6 MPa / 40 kg
Horizontal Laboratory Autoclave LHA-D32
Horizontal Laboratory Autoclave LHA-D32
  • Chamber Capacity : 450 Liters
  • Door Type : Single Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-D35

Horizontal Laboratory Autoclave LHA-D35

  • Chamber Capacity : 600 Liters
  • Door Type : Double Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-B18

Horizontal Laboratory Autoclave LHA-B18

  • Capacity : 200L
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
Horizontal Laboratory Autoclave LHA-K16

Horizontal Laboratory Autoclave LHA-K16

  • Capacity : 300 L
  • Design Pressure : -0.1 / 0.25 MPa
  • Max Working Pressure : 0.23 MPa
  • Design Temperature : 139°C
Horizontal Laboratory Autoclave LHA-D30 FAQ's
  • The Horizontal Laboratory Autoclave LHA-D30 comes with a spacious 400-liter chamber, making it highly suitable for high-volume sterilization in laboratories, CSSDs, pharmaceutical, and food industries. This large capacity allows for the sterilization of multiple loads or large instruments in a single cycle, significantly improving workflow efficiency in high-demand environments such as hospitals or research institutions.

  • The LHA-D30 autoclave is equipped with a PLC + HMI control system, featuring a 7.0-inch color touchscreen display. This advanced interface enables users to easily program, monitor, and adjust sterilization cycles. The inclusion of a built-in printer provides real-time cycle data and records for validation and audit purposes, ensuring operational transparency and regulatory compliance.

  • The LHA-D30 is engineered for high temperature accuracy, with a temperature control accuracy of ±0.2°C, display accuracy of 0.1°C, and temperature equilibrium within ±0.5°C. Its working temperature range of 105°C to 139°C and pressure tolerance of –0.1 to 0.5 MPa allow for tailored sterilization of sensitive and varied instruments. The safety valve opens at 0.28 MPa, preventing overpressure situations, ensuring a safe working environment.

  • The Horizontal Laboratory Autoclave LHA-D30 incorporates a liquid ring vacuum pump that supports both pre- and post-vacuum cycles. This –97 kPa vacuum rate enables deep air removal from porous loads, ensuring uniform steam penetration and effective sterilization of complex instruments like wrapped surgical tools, hollow instruments, and porous items.

  • To accommodate various load types and sterilization requirements, the LHA-D30 offers a highly flexible operation: • Sterilization time range: 0 to 999 minutes • Drying time range: 0 to 999 minutes This programmability makes it ideal for laboratories and institutions that handle a wide range of instruments with differing sterilization needs.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.