| Chamber Capacity | 200 Liters |
| Door Type | Double Door |
| Control System | PLC + HMI + Built-in Printer |
| Display | 7.0-inch Color Touchscreen |
| Design Pressure | –0.1 / 0.5 MPa |
| Working Pressure Range | 0 to 0.25 MPa |
| Safety Valve Opening Pressure | 0.28 MPa |
| Design Temperature | 150°C |
| Working Temperature Range | 105°C to 139°C |
| Temperature Control Accuracy | ≤ ± 0.2°C |
| Temperature Display Accuracy | 0.1°C |
| Temperature Equilibrium | ≤ ± 0.5°C |
| Sterilization Time Range | 0 to 999 min |
| Drying Time Range | 0 to 999 min |
| Vacuum Rate | –97 kPa |
| Vacuum System | Liquid Ring Vacuum Pump (Pre & Post) |
| Steam Consumption per Cycle | 14 kg |
| Water Consumption per Cycle | 110 kg |
| Power Consumption | 22 kW |
| Chamber Size (W × D × H) | 550 × 550 × 750 mm |
| Outer Dimensions (W × D × H) | 1290 × 1850 × 1200 mm |
| Net Weight | 650 kg |
Our Horizontal Laboratory Autoclave LHA-D25 effectively sterilizes a wide range of materials including unwrapped or wrapped instruments, glassware, rubber products, liquids, porous loads, and hollow instruments.
Download catalog for
Horizontal Laboratory Autoclave LHA-D25 Catalog
Available Range :
Horizontal Laboratory Autoclave LHA-D23 : 150 Liters Horizontal Laboratory Autoclave LHA-D24 : 200 Liters Horizontal Laboratory Autoclave LHA-D26 : 250 Liters Horizontal Laboratory Autoclave LHA-D28 : 360 Liters Horizontal Laboratory Autoclave LHA-D30 : 400 Liters Horizontal Laboratory Autoclave LHA-D32 : 450 Liters Horizontal Laboratory Autoclave LHA-D34 : 600 Liters Horizontal Laboratory Autoclave LHA-D36 : 800 Liters
Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.








The Horizontal Laboratory Autoclave LHA-D25 is engineered to handle intensive sterilization workloads efficiently. Its 200-liter chamber capacity allows large batch processing, while its robust double-door design minimizes the risk of cross-contamination—making it ideal for environments like hospitals, pharmaceutical labs, and research institutions. With a design temperature of 150°C and a working range of 105°C to 139°C, it ensures effective sterilization. The PLC + HMI system and 7.0-inch touchscreen provide intuitive control and real-time monitoring. Additionally, its liquid ring vacuum pump supports both pre and post-vacuum cycles, ensuring thorough steam penetration and drying for complex loads.
The intelligent PLC + HMI control system in the LHA-D25 provides a seamless interface for managing sterilization parameters. The 7.0-inch color touchscreen allows operators to easily program and monitor sterilization cycles, adjust temperature, pressure, and time settings, and track real-time performance data. The built-in printer supports documentation, which is essential for maintaining sterilization logs in medical, research, and industrial settings. The system also includes safety interlocks and error alerts to ensure safe and uninterrupted operation.
Safety is a top priority in the design of the Horizontal Laboratory Autoclave LHA-D25. It comes with built-in safety mechanisms, including a safety valve that opens at 0.28 MPa to relieve excess pressure. The temperature control accuracy of ±0.2°C and a display accuracy of 0.1°C ensure precise monitoring. The temperature equilibrium is maintained at less than equal to ± 0.5°C, preventing temperature spikes. Additionally, the double-door system is engineered to prevent accidental opening during cycles, reducing contamination and injury risks.
The LHA-D25 features a liquid ring vacuum pump capable of executing both pre-vacuum and post-vacuum functions. The vacuum rate reaches –97 kPa, allowing the autoclave to remove air effectively before steam injection, which is essential for sterilizing hollow and porous items. Post-vacuum cycles facilitate enhanced drying, making the equipment especially suitable for wrapped instruments and materials where moisture retention must be minimized.
Thanks to its high-capacity chamber, advanced sterilization control, and robust safety features, the Horizontal Laboratory Autoclave LHA-D25 is perfect for use in research laboratories, pharmaceutical manufacturing units, clinical hospitals, universities, and food or chemical testing facilities. It is ideal for sterilizing instruments, labware, rubber, glass, liquids, porous materials, and more. The double-door design makes it especially suitable for controlled environments such as cleanrooms or central sterile services departments (CSSD).
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608