Horizontal Laboratory Autoclave LHA-D26 features a spacious 250-liter chamber with a durable single-door design. It is designed to operate within a pressure range of 0 to 0.25 MPa and a temperature range of 105°C to 139°C.  Its liquid ring vacuum pump system provides efficient pre- and post-vacuum phases for enhanced sterilization of porous and hollow items. With a steam consumption and water consumption per cycle, this autoclave balances performance with resource efficiency.

Horizontal Laboratory Autoclave LHA-D26
Horizontal Laboratory Autoclave LHA-D26
Horizontal Laboratory Autoclave LHA-D26
Request Quote
Chamber Capacity 250 Liters
Door Type Single Door
Control System PLC + HMI + Built-in Printer
Display 7.0-inch Color Touchscreen
Design Pressure – 0.1 / 0.5 MPa
Working Pressure Range 0 to 0.25 MPa
Safety Valve Opening Pressure 0.28 MPa
Design Temperature 150°C
Working Temperature Range 105°C to 139°C
Temperature Control Accuracy Up to ± 0.2°C
Temperature Display Accuracy 0.1°C
Temperature Equilibrium Up to ± 0.5°C
Sterilization Time Range 0 to 999 min
Drying Time Range 0 to 999 min
Vacuum Rate – 97 kPa
Vacuum System Liquid Ring Vacuum Pump (Pre & Post)
Steam Consumption per Cycle 16 kg
Water Consumption per Cycle 120 kg
Power Consumption 22 kW
Chamber Size (W × D × H) 550 × 550 × 850 mm
Outer Dimensions (W × D × H) 1290 × 1850 × 1200 mm
Packing Dimension 1450 × 2050 × 1390 mm
Net Weight 750 kg
Gross Weight 950 kg
  • Large Chamber Capacity
  • Advanced Control System
  • User-Friendly Interface
  • High Sterilization Precision
  • Wide Operating Ranges
  • Efficient Vacuum System
  • Flexible Timing Options
  • Robust Safety Measures
  • Efficient Resource Use
  • Durable Design
  • Compact Footprint

Our Horizontal Laboratory Autoclave LHA-D26 is suitable for sterilizing a variety of materials including unwrapped or wrapped instruments, surgical tools, glassware, rubber items, liquids, culture media, porous loads, and hollow instruments.

Air Compressor

Horizontal Laboratory Autoclave LHA-D26 | Temperature Control Accuracy: Up to ± 0.2°C | Working Pressure Range: 0 to 0.25 MPa
Horizontal Laboratory Autoclave LHA-D26 | Flexible Timing Options | Advanced Control System

Models of Horizontal Autoclave

Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.

Horizontal Laboratory Autoclave LHA-J10

Horizontal Laboratory Autoclave LHA-J10

  • Capacity : 100L
  • Sterilization Temperature : 134℃
  • Working Pressure : 0 to 0.22Mpa
  • Timer Range : 0 to 99 min
Horizontal Laboratory Autoclave LHA-D29

Horizontal Laboratory Autoclave LHA-D29

  • Chamber Capacity : 360 Liters
  • Door Type : Double Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-I13

Horizontal Laboratory Autoclave LHA-I13

  • Capacity : 150 L
  • Designed Temperature : 150℃
  • Maximum Working Temperature : 139℃
  • Inner Chamber Pressure : -0.1 to 0.3 MPa
Horizontal Laboratory Autoclave LHA-A10
Horizontal Laboratory Autoclave LHA-A10
  • Capacity : 300 L
  • Sterilization Temperature : 105 to 138 ℃
  • Maximum Temperature : 138 ℃
  • Temperature uniformity : ≤ ± 0.5 ℃
Horizontal Laboratory Autoclave LHA-H13
Horizontal Laboratory Autoclave LHA-H13
  • Capacity : 300 L
  • Working Pressure : 0 to 0.22 MPa
  • Working Temperature : 134 °C
  • Temperature Range : 0 to 134 °C
Horizontal Laboratory Autoclave LHA-B14

Horizontal Laboratory Autoclave LHA-B14

  • Capacity : 500 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Timer Range : 0 - 60 minutes
Horizontal Laboratory Autoclave LHA-I20

Horizontal Laboratory Autoclave LHA-I20

  • Capacity : 90 L
  • Sterilization Temperature : 134 °C
  • Working Pressure : 0.22 MPa
  • Timer Range : 0 to 99 min
Horizontal Laboratory Autoclave LHA-D18

Horizontal Laboratory Autoclave LHA-D18

  • Capacity : 120 L
  • Working temperature : 105 °C to 134 °C
  • Sterilization temperature : 139 °C
  • Sterilization pressure : 0.245 MPa
Horizontal Laboratory Autoclave LHA-D26 FAQ's
  • The Horizontal Laboratory Autoclave LHA-D26 is designed with a spacious 250-liter chamber, making it suitable for handling a wide range of sterilization loads. It can sterilize unwrapped and wrapped instruments, surgical tools, glassware, rubber items, liquids, culture media, porous materials, and hollow instruments. Its large volume and versatile sterilization capability make it ideal for use in laboratories, hospitals, research institutions, and pharmaceutical environments.

  • The LHA-D26 operates efficiently within a working temperature range of 105°C to 139°C, with a design temperature of up to 150°C. Its working pressure range is 0 to 0.25 MPa, while the design pressure spans from –0.1 MPa to 0.5 MPa. These wide ranges enable the autoclave to accommodate various sterilization requirements across different load types and conditions.

  • The Horizontal Laboratory Autoclave LHA-D26 features an advanced PLC (Programmable Logic Controller) and HMI (Human Machine Interface) control system for precise monitoring and automation. The autoclave is equipped with a 7.0-inch color touchscreen display that allows users to control sterilization parameters easily, monitor cycle status in real time, and print sterilization records with the built-in printer.

  • Horizontal Laboratory Autoclave LHA-D26 is equipped with a liquid ring vacuum pump that supports both pre-vacuum and post-vacuum cycles. The vacuum rate reaches –97 kPa, ensuring efficient air removal before steam injection and effective drying after sterilization. This feature enhances sterilization quality, especially for porous loads and hollow instruments, by improving steam penetration and ensuring complete drying.

  • The LHA-D26 is engineered for resource efficiency without compromising performance. Each sterilization cycle consumes approximately 16 kg of steam and 120 kg of water, while the power consumption is 22 kW. These values reflect a balanced design that prioritizes both high sterilization output and optimized utility usage, helping facilities manage operational costs effectively.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.