Request A Quote
Horizontal Laboratory Autoclave LHA-D29

Horizontal Laboratory Autoclave LHA-D29

Horizontal Laboratory Autoclave LHA-D29 offers a spacious 360L chamber and a robust double-door design to ensure maximum contamination control. It incorporates a 7.0-inch color touchscreen and built-in printer for real-time monitoring, and record-keeping. With adjustable sterilization and drying time, it allows flexibility for diverse load types. It ensures durability, safety, and a compact design, ideal for modern labs and sterile processing settings.

Horizontal Laboratory Autoclave LHA-D29
Horizontal Laboratory Autoclave LHA-D29
Horizontal Laboratory Autoclave LHA-D29
Request Quote
Chamber Capacity 360 Liters
Door Type Double Door
Control System PLC + HMI + Built-in Printer
Display 7.0-inch Color Touchscreen
Design Pressure –0.1 / 0.5 MPa
Working Pressure Range 0 to 0.25 MPa
Safety Valve Opening Pressure 0.28 MPa
Design Temperature 150°C
Working Temperature Range 105°C to 139°C
Temperature Control Accuracy ≤ ± 0.2°C
Temperature Display Accuracy 0.1°C
Temperature Equilibrium ≤ ± 0.5°C
Sterilization Time Range 0 to 999 min
Drying Time Range 0 to 999 min
Vacuum Rate –97 kPa
Vacuum System Liquid Ring Vacuum Pump (Pre & Post)
Steam Consumption per Cycle 20 kg
Water Consumption per Cycle 160 kg
Power Consumption 32 kW
Chamber Size (W × D × H) 610 × 610 × 1000 mm
Outer Dimensions (W × D × H) 1290 × 1850 × 1350 mm
Net Weight 870 kg
  • Large Chamber Capacity
  • Double-Door Design 
  • PLC + HMI System 
  • Built-In Printer
  • Wide Working Temperature and Pressure Range
  • High Temperature and Pressure Accuracy
  • Pre- And Post-Vacuum Cycles 
  • Adjustable Sterilization and Drying Time
  • Efficient Steam and Water Consumption
  • High Power Performance 
  • Lab-Friendly Design

Our Horizontal Laboratory Autoclave LHA-D29 is suitable for sterilizing items that are resistant to high temperatures and pressures, including both unwrapped and wrapped instruments, surgical dressings, rubber materials, liquids, implantable instruments, porous items, and hollow instruments.

Horizontal Laboratory Autoclave LHA-D29 | Design Temperature: 150°C | Working Pressure Range: 0 to 0.25 MPa
Horizontal Laboratory Autoclave LHA-D29 | Built-In Printer | PLC + HMI System

Models of Horizontal Autoclave

Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.

Horizontal Laboratory Autoclave LHA-G12

Horizontal Laboratory Autoclave LHA-G12

  • Capacity : 280 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Timer Range : 0-60 minutes
Horizontal Laboratory Autoclave LHA-B20

Horizontal Laboratory Autoclave LHA-B20

  • Capacity : 500L
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
Horizontal Laboratory Autoclave LHA-D22

Horizontal Laboratory Autoclave LHA-D22

  • Capacity : 150L
  • Design Temperature : 150℃
  • Working Temperature Range : 105℃ to 138℃
  • Working Pressure Range : 0 to 0.25 MPa
Horizontal Laboratory Autoclave LHA-E10
Horizontal Laboratory Autoclave LHA-E10
  • Capacity : 150 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Timer Range : 0 - 99 minutes
Horizontal Laboratory Autoclave LHA-D30
Horizontal Laboratory Autoclave LHA-D30
  • Chamber Capacity : 400 Liters
  • Door Type : Single Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-B19

Horizontal Laboratory Autoclave LHA-B19

  • Capacity : 300L
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
Horizontal Laboratory Autoclave LHA-A10

Horizontal Laboratory Autoclave LHA-A10

  • Capacity : 300 L
  • Sterilization Temperature : 105 to 138 ℃
  • Maximum Temperature : 138 ℃
  • Temperature uniformity : ≤ ± 0.5 ℃
Horizontal Laboratory Autoclave LHA-D28

Horizontal Laboratory Autoclave LHA-D28

  • Chamber Capacity : 360 Liters
  • Door Type : Single Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-D29 FAQ's
  • The Horizontal Laboratory Autoclave LHA-D29 is engineered for demanding sterilization tasks, offering a spacious 360-liter chamber capacity and a robust double-door design, which enhances contamination control in sterile environments. Its PLC + HMI system, combined with a 7.0-inch color touchscreen and built-in printer, allows real-time monitoring and precise documentation of every sterilization cycle. The adjustable sterilization and drying time ensures flexibility for various types of load items, while its pre- and post-vacuum cycles improve penetration in porous and hollow materials. These features make it highly efficient and suitable for medical, research, and pharmaceutical laboratories.

  • The double-door design of the Horizontal Laboratory Autoclave LHA-D29 plays a crucial role in minimizing cross-contamination risks by separating loading and unloading zones, commonly used in cleanroom environments. This configuration ensures that sterilized items do not come into contact with non-sterile surfaces, thus maintaining sterile integrity. It is especially vital in healthcare and pharmaceutical settings where infection control and clean workflows are essential.

  • The LHA-D29 is equipped with an advanced PLC + HMI control system that offers intuitive operation through its 7.0-inch color touchscreen interface. The built-in printer records all sterilization data, which supports audit trails and compliance with regulatory requirements. Users can easily adjust parameters like temperature, sterilization time, and drying time. The intelligent system ensures stable operation, automated cycles, and consistent performance, reducing manual errors and enhancing productivity.

  • Yes, the Horizontal Laboratory Autoclave LHA-D29 is specifically designed to accommodate a wide range of sterilization loads including wrapped and unwrapped surgical instruments, medical dressings, rubber goods, liquids, implantable instruments, porous materials, and hollow instruments. Its pre- and post-vacuum capability, high temperature tolerance (105°C to 139°C), and flexible time settings (up to 999 minutes for sterilization and drying) make it suitable for sterilizing complex and varied items.

  • Safety and precision are top priorities in the LHA-D29. It includes a safety valve that opens at 0.28 MPa, ensuring safe pressure release under abnormal conditions. The autoclave also maintains temperature control accuracy within ± 0.2°C and temperature equilibrium within ± 0.5°C, supporting consistent sterilization results. Additionally, the design temperature is set at 150°C, providing ample margin for high-heat applications without compromising structural integrity.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.