| Chamber Capacity | 360 Liters |
| Door Type | Double Door |
| Control System | PLC + HMI + Built-in Printer |
| Display | 7.0-inch Color Touchscreen |
| Design Pressure | –0.1 / 0.5 MPa |
| Working Pressure Range | 0 to 0.25 MPa |
| Safety Valve Opening Pressure | 0.28 MPa |
| Design Temperature | 150°C |
| Working Temperature Range | 105°C to 139°C |
| Temperature Control Accuracy | ≤ ± 0.2°C |
| Temperature Display Accuracy | 0.1°C |
| Temperature Equilibrium | ≤ ± 0.5°C |
| Sterilization Time Range | 0 to 999 min |
| Drying Time Range | 0 to 999 min |
| Vacuum Rate | –97 kPa |
| Vacuum System | Liquid Ring Vacuum Pump (Pre & Post) |
| Steam Consumption per Cycle | 20 kg |
| Water Consumption per Cycle | 160 kg |
| Power Consumption | 32 kW |
| Chamber Size (W × D × H) | 610 × 610 × 1000 mm |
| Outer Dimensions (W × D × H) | 1290 × 1850 × 1350 mm |
| Net Weight | 870 kg |
Our Horizontal Laboratory Autoclave LHA-D29 is suitable for sterilizing items that are resistant to high temperatures and pressures, including both unwrapped and wrapped instruments, surgical dressings, rubber materials, liquids, implantable instruments, porous items, and hollow instruments.
Download catalog for
Horizontal Laboratory Autoclave LHA-D29 Catalog
Available Range :
Horizontal Laboratory Autoclave LHA-D23 : 150 Liters Horizontal Laboratory Autoclave LHA-D24 : 200 Liters Horizontal Laboratory Autoclave LHA-D26 : 250 Liters Horizontal Laboratory Autoclave LHA-D28 : 360 Liters Horizontal Laboratory Autoclave LHA-D30 : 400 Liters Horizontal Laboratory Autoclave LHA-D32 : 450 Liters Horizontal Laboratory Autoclave LHA-D34 : 600 Liters Horizontal Laboratory Autoclave LHA-D36 : 800 Liters
Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.








The Horizontal Laboratory Autoclave LHA-D29 is engineered for demanding sterilization tasks, offering a spacious 360-liter chamber capacity and a robust double-door design, which enhances contamination control in sterile environments. Its PLC + HMI system, combined with a 7.0-inch color touchscreen and built-in printer, allows real-time monitoring and precise documentation of every sterilization cycle. The adjustable sterilization and drying time ensures flexibility for various types of load items, while its pre- and post-vacuum cycles improve penetration in porous and hollow materials. These features make it highly efficient and suitable for medical, research, and pharmaceutical laboratories.
The double-door design of the Horizontal Laboratory Autoclave LHA-D29 plays a crucial role in minimizing cross-contamination risks by separating loading and unloading zones, commonly used in cleanroom environments. This configuration ensures that sterilized items do not come into contact with non-sterile surfaces, thus maintaining sterile integrity. It is especially vital in healthcare and pharmaceutical settings where infection control and clean workflows are essential.
The LHA-D29 is equipped with an advanced PLC + HMI control system that offers intuitive operation through its 7.0-inch color touchscreen interface. The built-in printer records all sterilization data, which supports audit trails and compliance with regulatory requirements. Users can easily adjust parameters like temperature, sterilization time, and drying time. The intelligent system ensures stable operation, automated cycles, and consistent performance, reducing manual errors and enhancing productivity.
Yes, the Horizontal Laboratory Autoclave LHA-D29 is specifically designed to accommodate a wide range of sterilization loads including wrapped and unwrapped surgical instruments, medical dressings, rubber goods, liquids, implantable instruments, porous materials, and hollow instruments. Its pre- and post-vacuum capability, high temperature tolerance (105°C to 139°C), and flexible time settings (up to 999 minutes for sterilization and drying) make it suitable for sterilizing complex and varied items.
Safety and precision are top priorities in the LHA-D29. It includes a safety valve that opens at 0.28 MPa, ensuring safe pressure release under abnormal conditions. The autoclave also maintains temperature control accuracy within ± 0.2°C and temperature equilibrium within ± 0.5°C, supporting consistent sterilization results. Additionally, the design temperature is set at 150°C, providing ample margin for high-heat applications without compromising structural integrity.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom