Request A Quote
Horizontal Laboratory Autoclave LHA-C10

Horizontal Laboratory Autoclave LHA-C10

Horizontal Laboratory Autoclave LHA-C10 operates within a temperature range of 50°C to 134°C. Its horizontal design with a front-opening door makes loading easier and more convenient. The three-tier basket system allows efficient use of chamber space for sterilizing varied loads. This design ensures effective sterilization of even heat-resistant materials. Our autoclave is ideal for sterilizing lab glassware, instruments, culture media, and biological waste in research, pharmaceutical, clinical, and industrial settings.

Horizontal Laboratory Autoclave LHA-C10
Horizontal Laboratory Autoclave LHA-C10
Horizontal Laboratory Autoclave LHA-C10
Horizontal Laboratory Autoclave LHA-C10
Horizontal Laboratory Autoclave LHA-C10
Request Quote
Capacity 200 L
Chamber Volume Φ500 × 1120 mm
Chamber Thickness 3.0 mm
Temperature Range 50 °C to 134 °C
Working Environment 5 °C to 45°C
Relative Humidity 10% to 85%
Rated Working Pressure 0.217 MPa
Sterilization Time Range 0 to 99 h
Power Supply 380 V
Rated Power 9000 W
Packing Size 1640 × 830 × 1800 mm
Dimension 1550 × 720 × 1640 mm
Gross Weight 300 Kg
  • Ergonomic Horizontal Design

  • Precise Digital Controls

  • Spacious Sterilization Chamber

  • Low Power Consumption

  • Robust Stainless-Steel Build

Our Horizontal Laboratory Autoclave LHA-C10 is widely used in hospitals, veterinary and dental clinics, food and beverage industries, research institutions, and agricultural labs to ensure contamination-free tools, equipment, and materials.

Horizontal Laboratory Autoclave LHA-C10 | Sterilization Time Range: 0 to 99 h | Temperature Range: 50 °C to 134 °C
Horizontal Laboratory Autoclave LHA-C10 | Ergonomic Horizontal Design | Precise Digital Controls

Models of Horizontal Autoclave

Labtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.

Horizontal Laboratory Autoclave LHA-D15

Horizontal Laboratory Autoclave LHA-D15

  • Capacity : 1500 L
  • Sterilization Temperature : 139 °C
  • Sterilization Pressure : 0.22MPa
  • Steam Pressure and the Consumption : 0.4 - 0.6 MPa / 50 kg
Horizontal Laboratory Autoclave LHA-D31

Horizontal Laboratory Autoclave LHA-D31

  • Chamber Capacity : 400 Liters
  • Door Type : Double Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-I15

Horizontal Laboratory Autoclave LHA-I15

  • Capacity : 120 L
  • Working Temperature Range : 105 ℃ to 139 ℃
  • Sterilization Temperature : 150 ℃
  • Sterilization Pressure : -0.1/0.3Mpa
Horizontal Laboratory Autoclave LHA-F15
Horizontal Laboratory Autoclave LHA-F15
  • Capacity : 1500 L
  • Sterilization Temperature : 139 °C
  • Sterilization Pressure : 0.25MPa
  • Steam Pressure and the Consumption : 0.4 - 0.6 MPa / 55 kg
Horizontal Laboratory Autoclave LHA-K14
Horizontal Laboratory Autoclave LHA-K14
  • Capacity : 200 L
  • Design Pressure : -0.1 / 0.25 MPa
  • Max Working Pressure : 0.23 MPa
  • Design Temperature : 139°C
Horizontal Laboratory Autoclave LHA-D34

Horizontal Laboratory Autoclave LHA-D34

  • Chamber Capacity : 600 Liters
  • Door Type : Single Door
  • Control System : PLC + HMI + Built-in Printer
  • Display : 7.0-inch Color Touchscreen
Horizontal Laboratory Autoclave LHA-D10

Horizontal Laboratory Autoclave LHA-D10

  • Capacity : 250 L
  • Sterilization Temperature : 139 °C
  • Sterilization Pressure : 0.22MPa
  • Steam Pressure and the Consumption : 0.4 - 0.6 MPa / 15 kg
Horizontal Laboratory Autoclave LHA-K10

Horizontal Laboratory Autoclave LHA-K10

  • Capacity : 100 L
  • Design Pressure : -0.1 / 0.25 MPa
  • Max Working Pressure : 0.23 MPa
  • Design Temperature : 139°C
Horizontal Laboratory Autoclave LHA-C10 FAQ's
  • Yes, the Horizontal Autoclave LHA-C10 supports customizable and programmable sterilization cycles. Operators can set specific temperature, pressure, and time parameters depending on the materials being sterilized. This flexibility ensures optimal performance for diverse applications, from delicate instruments to dense biological waste. Preset programs can also be stored for frequently repeated processes. The programmable function helps maintain consistency and reliability across multiple sterilization runs. It enhances efficiency and precision in high-demand environments.

  • The Horizontal Autoclave LHA-C10is designed with user convenience in mind. Its front-opening horizontal door allows easy loading and unloading, even with heavy or bulky items. The digital control panel offers intuitive navigation for selecting and customizing sterilization cycles. Real-time indicators display cycle progress, temperature, and pressure. It requires minimal training to operate, making it suitable for both experienced and new users. Maintenance access points are also conveniently located for quick service.

  • The Horizontal Autoclave LHA-C10features a horizontal front-loading design for easy access and loading. It comes with a large 200-liter chamber and a three-tier basket system to accommodate various load types. Its stainless-steel construction ensures durability and corrosion resistance. The digital control panel allows users to program sterilization cycles accurately. Built-in safety systems monitor temperature and pressure during operation. This ensures both effective sterilization and operator safety.

  • Yes, the Horizontal Autoclave LHA-C10 can safely sterilize liquids such as culture media or buffer solutions. It includes settings specifically designed to account for the longer heating and cooling times needed for liquids. The temperature is gradually increased and decreased to avoid boiling or sample loss. Pressure and temperature sensors ensure the correct conditions are maintained throughout the cycle. It is important to use heat-resistant and sealed containers for liquid sterilization. This ensures both safety and effectiveness.

  • Absolutely, the Horizontal Autoclave LHA-C10 is built for durability and high-volume, continuous sterilization tasks. Its robust construction and powerful heating system allow it to perform reliably in demanding industrial and research settings. The large chamber supports multiple cycles per day without overheating or mechanical strain. Cooling and steam release systems are engineered for repeated use. Proper maintenance ensures consistent results over long periods. This makes it ideal for facilities with high sterilization throughput.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.