Horizontal Laboratory Autoclave LHA-B14 is a microprocessor controlled automatic autoclave.It has a capacity of 500 L and a maximum working temperature of 134 °C. Equipped with safety features like automatic shutoff preventing overload of current, auto protection against raised temperature and pressure making a reliable and user friendly device.
Capacity | 500 L |
Sterilization Temperature | 134 °C |
Sterilization Pressure | 0.22 MPa |
Timer Range | 0 - 60 minutes |
Heat Average | ≤ ± 1 ℃ |
Chamber Dimensions ( Φ × D ) | 700 × 1300 mm |
Product Dimension ( L × W × H ) | 1800 × 900 × 1820 mm |
Net Weight | 470 kg |
Gross Weight | 580 kg |
Power Supply | 18 kW / AC 380 V 50 Hz |
Horizontal autoclave with cylindrical shape is suitable for medical, laboratory, microbiological, clinical use and to sterile the waste before discarding.
Download catalog for
Horizontal Laboratory Autoclave LHA-B14 Catalog
Available Range :
Horizontal Autoclave LHA-J10 : 100L Horizontal autoclave LHA-D18 : 120 L Horizontal Laboratory Autoclave LHA-D14 : 1200 L Horizontal Autoclave LHA-D20 : 150 L Horizontal Laboratory Autoclave LHA-D15 : 1500 L Horizontal Autoclave LHA-D21 : 1500L Horizontal Autoclave LHA-B15 : 150L Horizontal Autoclave LHA-I14 : 180 L Horizontal Laboratory Autoclave LHA-B11 : 200 L Horizontal Laboratory Autoclave LHA-D16 : 2000 L Horizontal Autoclave LHA-I16 : 2000L Horizontal Laboratory Autoclave LHA-D10 : 250 L Horizontal Laboratory Autoclave LHA-B12 : 280 L Horizontal Laboratory Autoclave LHA-A10 : 300 L Horizontal Laboratory Autoclave LHA-D11 : 360 L Horizontal Laboratory Autoclave LHA-B13 : 400 L Horizontal Laboratory Autoclave LHA-A11 : 500 L Horizontal Autoclave LHA-I10 : 60 L Horizontal Laboratory Autoclave LHA-D12 : 600 L Horizontal Autoclave LHA-I11 : 80 L Horizontal Laboratory Autoclave LHA-D13 : 800 L Horizontal Autoclave LHA-I20 : 90 Lmodels of Horizontal Autoclave
Yes, the Horizontal Laboratory Autoclave LHA-B14 comes with a highly efficient drainage system designed to remove residual water and steam post-sterilization. This prevents any water buildup inside the chamber, maintaining a clean and dry interior. The drainage system is also easy to access for regular cleaning and maintenance, ensuring smooth operation over time. Proper drainage is crucial for extending the lifespan of the autoclave and preventing microbial growth. By keeping the chamber dry after each cycle, it also reduces corrosion risks and helps maintain consistent sterilization quality.
Our Horizontal Laboratory Autoclave is specifically engineered for repeated and intensive daily use in busy laboratory settings. Its sturdy construction ensures that components can withstand frequent sterilization cycles without compromising performance. The autoclave is equipped with advanced heating and steam generation systems that ensure rapid and consistent operation throughout the day. High-grade materials used in the chamber and seals contribute to the durability of the unit. It’s a great choice for labs where sterilization demands are high, offering both reliability and long-term service.
Labtron’s Horizontal Laboratory Autoclave features a secure mechanical and pressure-dependent door-locking system to ensure user safety. The locking mechanism engages automatically during operation and prevents the door from opening until internal pressure has dropped to a safe level. This system avoids accidental exposure to high-temperature steam, reducing the risk of burns. The lock is designed for a tight seal that prevents leaks during sterilization. Additionally, safety interlocks and pressure gauges allow operators to monitor status, adding another layer of operational safety.
Yes, Labtron’s Horizontal Laboratory Autoclave allows users to fully adjust sterilization parameters, including temperature, pressure, and time. This feature makes it suitable for sterilizing a wide range of materials like glassware, metal tools, and culture media without causing damage. The flexible programming lets operators optimize cycles according to specific load types, improving both efficiency and safety. Adjustable settings make it adaptable to changing laboratory needs and various sterilization protocols. These custom options ensure thorough sterilization even for sensitive or specialty items.
Even steam circulation ensures that the Horizontal Laboratory Autoclave LHA-B14 achieves uniform heat distribution inside the chamber. High-pressure steam reaches every surface, ensuring no cold spots remain, which is crucial for complete sterilization. The chamber is designed to optimize steam flow so that densely packed instruments are sterilized evenly. Consistent heating eliminates variability between cycles, giving labs reliable and predictable results. This makes it especially effective for sterilizing complex or multi-part instruments that require deep penetration of steam.
The horizontal Laboratory Autoclave requires strict adherence to safety guidelines to ensure safe and effective operation. Always wait for internal pressure to fully release before attempting to open the door to avoid accidents. Never overload the chamber as this can affect steam circulation and sterilization quality. Check water levels before each cycle to ensure proper steam generation. Perform routine maintenance and inspection of seals and valves to prevent operational failures. Following these precautions will help extend the life of the autoclave and maintain user safety.