Horizontal Laboratory Autoclave LHA-B14

Horizontal Laboratory Autoclave LHA-B14

Horizontal Laboratory Autoclave LHA-B14 is a microprocessor controlled automatic autoclave.It has a capacity of 500 L and a maximum working temperature of 134 °C. Equipped with safety features like automatic shutoff preventing overload of current, auto protection against raised temperature and pressure making a reliable and user friendly device.

Request Quote
Capacity 500 L
Sterilization Temperature 134 °C
Sterilization Pressure 0.22 MPa
Timer Range 0 - 60 minutes
Heat Average ≤ ± 1 ℃
Chamber Dimensions ( Φ × D ) 700 × 1300 mm
Product Dimension ( L × W × H ) 1800 × 900 × 1820 mm
Net Weight 470 kg
Gross Weight 580 kg
Power Supply 18 kW / AC 380 V 50 Hz
  • Microprocessor control with fully automatic cycles
  • Digital LCD display to monitor working status and parameters
  • Working pressure : 0.22 MPa
  • Working temperature : 134 ℃
  • Automated drying function
  • Door lock feature : Door cannot be opened till the pressure inside the chamber doesn’t fall to 0.027 MPa
  • Safe door lock system ensuring safety / protection during sterilization
  • Automatic power cut off with alarm with low water levels indication

Horizontal autoclave with cylindrical shape is suitable for medical, laboratory, microbiological, clinical use and to sterile the waste before discarding.

models of Horizontal Autoclave

Related Sub-Category


Horizontal Laboratory Autoclave LHA-B14 FAQ's
  • Yes, the Horizontal Laboratory Autoclave LHA-B14 comes with a highly efficient drainage system designed to remove residual water and steam post-sterilization. This prevents any water buildup inside the chamber, maintaining a clean and dry interior. The drainage system is also easy to access for regular cleaning and maintenance, ensuring smooth operation over time. Proper drainage is crucial for extending the lifespan of the autoclave and preventing microbial growth. By keeping the chamber dry after each cycle, it also reduces corrosion risks and helps maintain consistent sterilization quality.

  • Our Horizontal Laboratory Autoclave is specifically engineered for repeated and intensive daily use in busy laboratory settings. Its sturdy construction ensures that components can withstand frequent sterilization cycles without compromising performance. The autoclave is equipped with advanced heating and steam generation systems that ensure rapid and consistent operation throughout the day. High-grade materials used in the chamber and seals contribute to the durability of the unit. It’s a great choice for labs where sterilization demands are high, offering both reliability and long-term service.

  • Labtron’s Horizontal Laboratory Autoclave features a secure mechanical and pressure-dependent door-locking system to ensure user safety. The locking mechanism engages automatically during operation and prevents the door from opening until internal pressure has dropped to a safe level. This system avoids accidental exposure to high-temperature steam, reducing the risk of burns. The lock is designed for a tight seal that prevents leaks during sterilization. Additionally, safety interlocks and pressure gauges allow operators to monitor status, adding another layer of operational safety.

  • Yes, Labtron’s Horizontal Laboratory Autoclave allows users to fully adjust sterilization parameters, including temperature, pressure, and time. This feature makes it suitable for sterilizing a wide range of materials like glassware, metal tools, and culture media without causing damage. The flexible programming lets operators optimize cycles according to specific load types, improving both efficiency and safety. Adjustable settings make it adaptable to changing laboratory needs and various sterilization protocols. These custom options ensure thorough sterilization even for sensitive or specialty items.

  • Even steam circulation ensures that the Horizontal Laboratory Autoclave LHA-B14 achieves uniform heat distribution inside the chamber. High-pressure steam reaches every surface, ensuring no cold spots remain, which is crucial for complete sterilization. The chamber is designed to optimize steam flow so that densely packed instruments are sterilized evenly. Consistent heating eliminates variability between cycles, giving labs reliable and predictable results. This makes it especially effective for sterilizing complex or multi-part instruments that require deep penetration of steam.

  • The horizontal Laboratory Autoclave requires strict adherence to safety guidelines to ensure safe and effective operation. Always wait for internal pressure to fully release before attempting to open the door to avoid accidents. Never overload the chamber as this can affect steam circulation and sterilization quality. Check water levels before each cycle to ensure proper steam generation. Perform routine maintenance and inspection of seals and valves to prevent operational failures. Following these precautions will help extend the life of the autoclave and maintain user safety.

Post your question?

Our experts are here to help!

Horizontal Autoclave:
Horizontal Laboratory Autoclave LHA-A11, Horizontal Laboratory Autoclave LHA-B12, Horizontal Laboratory Autoclave LHA-B11, Horizontal autoclave LHA-D18, Horizontal Laboratory Autoclave LHA-E11, Horizontal Laboratory Autoclave LHA-F12, Horizontal Laboratory Autoclave LHA-D13, Horizontal Laboratory Autoclave LHA-B10, and more.

Quick Links : About Us, Contact Us, User Manuals, Career, Terms of Use, Policies, Sitemap, Gallery.

Need a Product

send details for best price quotation

Click
For

Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.