Horizontal Laboratory Autoclave LHA-B16 is designed with a 400L sterilizing chamber for high-volume sterilization. It operates at a working pressure of 0.22 MPa, ensuring effective steam penetration. The temperature is adjustable from 105°C to 134°C, allowing flexibility for different sterilization needs. Designed with an automatic control system, it simplifies operation and ensures efficient performance. Ideal for laboratories and medical facilities, it provides safe and reliable sterilization of instruments and materials.
Capacity | 400 L |
Sterilization Pressure | 0.22 MPa |
Sterilization Temperature | 134°C |
Temperature Adjustment | 105°C to 134°C |
Time Range | 0 to 250 min |
Drying Time Accuracy | 0 to 250 min |
Heat Average | ≤±1°C |
Power Supply | 18kW / 380V, 50Hz |
Chamber Dimension | φ700×1100mm |
Product Dimension | 1430 × 880 × 1830 mm |
Packaging Dimension | 1800×1050×2100 mm |
Net Weight | 520 kg |
Gross Weight | 530 kg |
Our Horizontal Laboratory Autoclave LHA-B16 sterilizes instruments, glassware, culture media, and biohazard waste. It is ideal for labs, pharmaceuticals, and medical facilities requiring bulk sterilization.
Download catalog for
Horizontal Laboratory Autoclave LHA-B16 Catalog
Available Range :
Horizontal Laboratory Autoclave LHA-K10 : 100 L Horizontal Laboratory Autoclave LHA-F17 : 10000L Horizontal Autoclave LHA-J10 : 100L Horizontal Autoclave LHA-D18 : 120 L Horizontal Laboratory Autoclave LHA-D14 : 1200 L Horizontal Autoclave LHA-D20 : 150 L Horizontal Laboratory Autoclave LHA-D15 : 1500 L Horizontal Autoclave LHA-D21 : 1500L Horizontal Autoclave LHA-B15 : 150L Horizontal Autoclave LHA-I14 : 180 L Horizontal Laboratory Autoclave LHA-B11 : 200 L Horizontal Laboratory Autoclave LHA-D16 : 2000 L Horizontal Autoclave LHA-I16 : 2000L Horizontal Laboratory Autoclave LHA-B18 : 200L Horizontal Laboratory Autoclave LHA-D10 : 250 L Horizontal Laboratory Autoclave LHA-B12 : 280 L Horizontal Laboratory Autoclave LHA-A10 : 300 L Horizontal Laboratory Autoclave LHA-B19 : 300L Horizontal Laboratory Autoclave LHA-D11 : 360 L Horizontal Laboratory Autoclave LHA-B13 : 400 L Horizontal Laboratory Autoclave LHA-A11 : 500 L Horizontal Laboratory Autoclave LHA-B20 : 500L Horizontal Autoclave LHA-I10 : 60 L Horizontal Laboratory Autoclave LHA-D12 : 600 L Horizontal Autoclave LHA-I11 : 80 L Horizontal Laboratory Autoclave LHA-D13 : 800 L Horizontal Autoclave LHA-I20 : 90 LLabtron Horizontal Autoclave features side-loading capability with capacities ranging from 50 L to 2000 L. Their integrated steam generators provide a steady supply of sterilization vapors at temperatures from 105℃ to 150℃. Equipped with gauges for precise pressure monitoring and a display for checking pressure. The doors are safely interlocked, preventing accidental opening during operation. These Horizontal Autoclave efficiently sterilize medical and laboratory equipment by eliminating harmful microbes.
The Horizontal Laboratory Autoclave has multiple safety mechanisms, including an automatic door-locking system that prevents opening until the internal pressure drops to 0.027 MPa. It is equipped with over-temperature and over-pressure protection to prevent operational hazards. If the pressure exceeds 0.24 MPa, the safety valve automatically releases steam into the water tank. The autoclave also shuts off power and activates an alarm in case of water shortage, ensuring safe operation in laboratory and medical settings.
Labtron’s Horizontal Laboratory Autoclave is designed to sterilize laboratory instruments, glassware, culture media, and biohazard waste. It effectively removes contaminants from reusable medical tools, surgical instruments, and laboratory supplies. With an adjustable temperature range from 105°C to 134°C, it accommodates various sterilization requirements. The drying function makes it particularly suitable for sterilizing dressings and porous materials that must remain moisture-free.
Our Horizontal Laboratory Autoclave includes a drying function that removes residual moisture from sterilized items, ensuring they are completely dry after the cycle. This feature is essential for sterilizing dressings, glassware, and surgical instruments that must remain moisture-free to prevent contamination. The drying function enhances the effectiveness of sterilization and ensures that instruments are ready for immediate use.
The Horizontal Laboratory Autoclave is equipped with an automatic pressure-release valve that activates if the internal pressure exceeds 0.24 MPa, directing excess steam into the water tank. This prevents over-pressurization and protects both the autoclave and the user. The door remains locked until the pressure drops to 0.027 MPa to prevent accidental steam exposure. These built-in safeguards ensure the autoclave operates safely under all conditions.
Labtron’s Horizontal Laboratory Autoclave requires regular maintenance to ensure long-term performance. The sterilization chamber should be cleaned periodically to prevent residue buildup. Water levels must be checked before each use to avoid dry heating, and the safety valve should be inspected to confirm proper operation. Testing the automatic cut-off system and door-sealing mechanism ensures continued reliability. Performing these maintenance tasks helps extend the lifespan of the autoclave.
The Horizontal Laboratory Autoclave is suitable for sterilizing liquid media, but users must select appropriate sterilization cycles to prevent liquid loss or boiling over. The autoclave’s gradual depressurization system ensures the safe handling of liquids by preventing sudden pressure changes. Proper placement of liquid containers and adherence to sterilization guidelines help achieve uniform results. This feature makes the autoclave effective for both solid and liquid sterilization needs.
Our Horizontal Laboratory Autoclave includes an automatic water-level monitoring system that detects when water levels are low. If the water supply runs out, the autoclave automatically shuts off power and triggers an alarm to prevent overheating. This protective feature ensures safe and uninterrupted operation. Regularly checking and refilling the water reservoir helps maintain the autoclave’s reliability and performance.
Labtron’s Horizontal Laboratory Autoclave should not be overloaded, as this can reduce steam penetration and affect sterilization efficiency. The door must be securely closed before starting a cycle, as the autoclave will not operate otherwise. After sterilization, the pressure must drop to a safe level before opening the door. Regular inspection of the pressure-release valve and door-locking mechanism ensures safe and effective long-term use.