Request A Quote
Whiteness Meter LWM-A12

Whiteness Meter LWM-A12

Whiteness meter LWM-A12 features a low zero drift of ≤ 0.1 %, which ensures precise and reliable measurements even during extended operation and repeated testing. The compact, advanced circuit design ensures the accuracy and stability of measurement data. It measures ISO (R457) whiteness and fluorescence whitening of the materials. Our whiteness meter is provided with light absorber to eliminate the influence of specular reflection of the sample.

Request Quote
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Indication drift ≤ 0.1 %
Indication error ≤ 0.5 %
Repeatability error ≤ 0.1 %
Mirror reflection error ≤ 0.1 %
Dimension (L*W*H) 360 × 264 × 400 mm
Net weight 20 kg
Power supply 220 V ± 10 %, 50 Hz
  • Stimulated D65 illumination
  • D/0 Viewing Geometry
  •  Brightness Value Determination
  • Opacity Measurement Capability
  • Transparency Determination Function

Whiteness Meter LWM-A12 quantifies a surface or powder’s whiteness by measuring blue-light reflectance. It plays a key role in ceramics, chemical material, printing inks and dyeing industries for ensuring uniform whiteness.

Models of Paper Testing Instruments

Labtron Paper Testing Instruments requires air supply for automatic clamping, ensuring smooth and secure operation. These provide real-time pressure curve displays, allowing users to monitor pressure changes instantly. Their over-range reset function protects the sensor by automatically adjusting it in case of excessive readings. They measure ink absorption values, useful for quality control in printing processes. Our paper testing instruments measure WH Hunter whiteness, YI yellowness, and CIE whiteness for precise color and whiteness evaluations for various applications.

Ink Rub Tester LIRT-A10

Ink Rub Tester LIRT-A10

  • Sample Area : 230 × 60 mm
  • Friction Stroke : 60 mm
  • Frequency Setting : 0 to 9999 auto-complete
  • Friction Area : 150 × 50 mm
Electronic Tear Tester LET-A10

Electronic Tear Tester LET-A10

  • Measuring Range : 10 to 64000 mN
  • Power of Resolution : 0.1 mN
  • Test Accuracy : ± 1%
  • Tearing Force Arm : 104 ± 1 mm
Vertical Tensile Tester LVTT-D10

Vertical Tensile Tester LVTT-D10

  • Capacity (MAX) : 1KN (optional 10N~1KN force sensor)
  • Control Method : Full computer control mode, powerful software
  • Unit of Force : N, kN, gf, kgf, lbf, kP, tf(SI), tf (long)...
  • Unit of Length : Mm, cm, Inch, m, km, um..
Water absorption tester TP-C20
Water absorption tester TP-C20
  • Measurement range : 0 to 200 mm
  • Specimen size : 15×250 mm
  • Division value : 1 mm
  • Number of specimen holders : 5
Paper tearing tester TP-J20
Paper tearing tester TP-J20
  • Measuring range : 0 to 1000 mN
  • Resolution : 0.1 mN
  • Indication error : ± 1 %
  • Tearing arm : 104 ± 1 mm
Mullen Burst Tester LMBT-A12

Mullen Burst Tester LMBT-A12

  • Measuring Range : Standard: 50 to 1200 kPa (paper) Optional: 250 to 5600 kPa (paperboard)
  • Indicating Accuracy : Up to ± 0.5%
  • Resolution : 0.1 kPa
  • Clamping Force : 400 kPa to 1200 kPa (adjustable)
Folding endurance tester TP-M10

Folding endurance tester TP-M10

  • Measuring scope : 0 to 99999 s
  • Folding angle : 135° ± 2°
  • Tensile scope : 4.9 to 14.7 N
  • Folding head suture size : 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Whiteness Meter LWM-A11

Whiteness Meter LWM-A11

  • Incidence Angle : 45/0
  • Measurement Range : 0 to199.9
  • Whiteness Formula : Whiteness of Blue Light
  • Light Source : D65
Whiteness Meter LWM-A12 FAQ's
  • Labtron LWS-A12 is fully capable of measuring the whiteness of a wide range of powders. It is designed to handle fine particulate samples and provides reliable and accurate readings under normal testing conditions. Specifically, powders with particle sizes approximately between 120 µm and 200 µm fall well within the operational capability of the instrument. However, samples that are exceptionally coarse—such as those resembling the size of rice grains or beans—may not yield accurate readings and are generally not recommended for whiteness measurement using this device.

  • Yes, the standard package of the Whiteness Meter LWS-A12 includes calibration material. This material allows users to perform routine checks and adjustments to ensure measurement consistency and accuracy. You can use it to verify that your device is stable before conducting your whiteness measurements, even though a formal certificate is not provided.

  • Yes, Labtron supplies advanced whiteness meter LWM-A12.These systems often feature conveyor integration or robotic positioning and provide real-time feedback for process control. Inline meters typically share core measurement principles with benchtop models but are ruggedized and designed for continuous operation. They include automated calibration routines, UV compensation, and centralized data logging to maintain quality without manual intervention—making them ideal for large-scale manufacturing.

  • Labtron supplies advanced whiteness meter LWM-A12. For powders, starch, sugar, or granules, compaction into a tablet or insertion into a powder sample holder is required before measurement. Ensure homogeneous particle size and consistent packing density to avoid air gaps and uneven surface reflection. Many instruments specify sample mass (e.g., ??5?g) and container dimensions to standardize readings. Thorough shaking and leveling of the powder improves repeatability, and cleaning the aperture after each measurement prevents residual interference

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.