Labtron is the supplier of Jacketed Glass Reactor LJGR-A46 with a 100 mm drain port clearance that supports safe discharge and convenient sample collection. Its 25 mm jacket interface ensures steady liquid circulation using standard thermal connectors.

Jacketed Glass Reactor LJGR-A46
Jacketed Glass Reactor LJGR-A46
Request Quote
Glass Vessel Volume 1 L Cylindrical
Dropping Funnel Volume 200 ml
Dropping Funnel Interface 24/29
Glass Vessel Flange Φ 105 mm
Glass Vessel Opening OD Φ 150 mm
Glass Material 3.3 Borosilicate
Support Parts of Stirrer PTFE and PEED glass
Bottom Valve ID Φ 10mm
Jacket interface 25 mm
Jacket Interface Pressure Limit Less than or equal to 0.03 Mpa
Circulation Hose Connection Port Rc1/2 and Rc3/4
Glass Vessel Lid Openings 5
Center Opening of Lid 24/40
Side Opening of Lid 24/40×3, 19/26
Seal Ring on Vessel Lid Φ148×Φ105×3
Drain Port Ground Clearence 100 mm
Stirring Speed 40 to 500 rpm
Condenser Interface 24/29
Condenser Area 0.025 m
Receiving Bottle Optional
Power Consumption 50 W
Dimensions (W×D×H) 480×420×1100 mm
  • Glide-action vessel rotation
  • Impact-resistant glass framework
  • Corrosion-resistant sealing components

  • Vibration-dampening motor mount

  • Adjustable stirring speed mechanism

Jacketed Glass Reactor LJGR-A46 supports temperature-controlled chemical reactions for material synthesis, distillation, and concentration. This enables consistent results in pharmaceutical, chemical, and academic research environments.

Models of Jacketed Glass Reactor

Jacketed Glass Reactor supports controlled mixing with adjustable stirring speed, ensuring consistent reaction dynamics in varied experiments. They maintain thermal stability using a jacketed layer for fluid circulation without exposing the medium. Their borosilicate glass build withstands thermal stress and chemical exposure over time. These systems include a display panel for monitoring key parameters during operation. Our glass reactor is suited for synthesis, distillation, extraction, crystallization, and pharmaceutical development.

Jacketed Glass Reactor LJGR-A38

Jacketed Glass Reactor LJGR-A38

  • Glass Vessel Volume : 20 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 205 mm
  • Jacketed Volume : 5000 ml
  • Dropping Funnel : 50 ml
Jacketed Glass Reactor LJGR-A31

Jacketed Glass Reactor LJGR-A31

  • Glass Vessel Volume : 30 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 265 mm
  • Jacketed Volume : 9000 ml
  • Dropping Funnel : 2000 ml
Jacketed Glass Reactor LJGR-B18

Jacketed Glass Reactor LJGR-B18

  • Glass Vessel Volume : 100 L Cylindrical
  • Dropping Funnel Volume : 10000 mL
  • Receiving Bottle : 20000 mL
  • Dropping Funnel Interface : Φ12.5
Jacketed Glass Reactor LJGR-B25
Jacketed Glass Reactor LJGR-B25
  • Glass Vessel Volume : 200 L
  • Jacketed Volume : 28 L
  • Flanged out of the oil circulation port : Low feed high outlet
  • Reaction bottle cover : Six port
Jacketed Glass Reactor LJGR-A18
Jacketed Glass Reactor LJGR-A18
  • Glass Vessel Volume : 1 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 150 mm
  • Jacketed Volume : 200 ml
  • Dropping Funnel : 250 ml
Jacketed Glass Reactor LJGR-A33

Jacketed Glass Reactor LJGR-A33

  • Glass Vessel Volume : 100 L Cylindrical
  • Glass Vessel Lid Diameter : Φ 340 mm
  • Jacketed Volume : 20000 ml
  • Dropping Funnel : 2000 ml
Jacketed Glass Reactor LJGR-B24

Jacketed Glass Reactor LJGR-B24

  • Glass Vessel Volume : 100 L
  • Jacketed Volume : 18 L
  • Flanged out of the oil circulation port : Low feed high outlet
  • Reaction bottle cover : Six port
Jacketed Glass Reactor LJGR-B23

Jacketed Glass Reactor LJGR-B23

  • Glass Vessel Volume : 50 L
  • Jacketed Volume : 12 L
  • Flanged out of the oil circulation port : Low feed high outlet
  • Reaction bottle cover : Six port

Jacketed Glass Reactor LJGR-A46 FAQ's
  • Our Jacketed Glass Reactor LJGR-A46 integrates chemically resistant contact components, making it suitable for handling reactive compounds in demanding environments. The internal parts that meet media are composed of specialized materials that reduce interaction with corrosive or volatile samples. This structural integrity allows complex chemical transformations without compromising purity. Its configuration protects both reagents and operators from cross-reaction concerns. The inner pathway is designed to restrict leaching or byproduct interference. No residual traces from previous batches impact current processes. This makes it ideal for pharmaceutical synthesis and intermediate trials. Researchers working on sensitive media benefit from reduced cross-contamination concerns.

  • Labtron’s Jacketed Glass Reactor LJGR-A46 is compatible with optional structural configurations for filtration work. When requested, the design can incorporate filter-supporting components to separate solids from liquid phases within the same unit. This allows sample clarification, crystallization work, and post-reaction separation in a single container. The discharge mechanism can be modified to support filtrate collection, removing the need to transfer contents externally. These adaptations retain the jacket’s thermal control functionality. Operating with minimal transfer ensures reduced exposure to air-sensitive compounds. The reactor maintains full visibility, even during filtration, supporting real-time visual checks. This makes it ideal for workflows needing rapid purification steps.

  • The Jacketed Glass Reactor LJGR-A46 includes ergonomic build elements that support researchers during extended usage. Its structure and port positioning allow access without repetitive awkward motions. Stirring adjustments, temperature circulation, and sample collection can be managed from a single operator station. The insulation hoses also play a critical role by absorbing tension from pipe installations. These reduce potential impact to the vessel walls caused by frequent disconnection. In addition, the robust base provides vibration dampening, even when operating at high speeds. Every component is arranged to lessen handling fatigue and increase safety. Users conducting long reaction cycles will find setup and teardown considerably less stressful.

  • The Jacketed Glass Reactor LJGR-A46 features a well-constructed lid system that offers multiple entry points without compromising tightness. Its seal arrangement accommodates simultaneous insertion of probes, sensors, and funnels with reliable closure. This design eliminates air gaps that could otherwise affect pressure stability during prolonged operations. The interface design prioritizes practical utility in multi-variable test setups. Each opening is constructed to interlock with standard connectors while resisting distortion from repeated use. The integrity of the joint system remains unaffected when various instruments are inserted together. Even in dynamic stirring or thermal cycling, no vapor loss or spillage is observed. It allows uninterrupted control over complex workflows.

  • Labtron’s Jacketed Glass Reactor LJGR-A46 has been tailored to accommodate recovery systems for low-boiling compounds. The structural design supports downstream connectivity with condensers and receiving trays without modification. Its layout supports flow from reaction chamber to receiving point without spillage or evaporation. Volatile substances can be collected effectively without losing material integrity. The ports and transitions support integration with vapor collection accessories. Researchers working on solvent recovery, essential oil isolation, or distillation of light organics benefit from this compatibility. It also supports safe re-use of reagents where regulatory or cost considerations apply. Its pathway ensures minimal loss during collection.

  • The Jacketed Glass Reactor LJGR-A46 offers side openings configured to support probe insertion without obstructing core operations. These entry points are distributed to allow simultaneous sensor placement for temperature, pH, or conductivity without overlap. The layout prevents sensor interference during stirring or heating. Probes can remain submerged throughout the run, providing continuous feedback. No special adapters are required, as standard glass joints are compatible. Researchers can implement real-time monitoring without redesigning their workflow. These sensor placements are ideal for kinetic studies, feedback-based dosing, or safety alarms. The vessel lid offers clean cable routing to reduce clutter.

Post your question?

Our experts are here to help!

Jacketed Glass Reactor:
Jacketed Glass Reactor LJGR-A38, Jacketed Glass Reactor LJGR-A31, Jacketed Glass Reactor LJGR-B18, Jacketed Glass Reactor LJGR-B25, Jacketed Glass Reactor LJGR-A18, Jacketed Glass Reactor LJGR-A33, Jacketed Glass Reactor LJGR-B24, Jacketed Glass Reactor LJGR-B23, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.